Empowering Scientific Discovery

Shanghai Chu Bai Laboratory Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNF
OriginGermany
ModelSIMDOS FEM1.10
Pump TypeDiaphragm Pump (Not Peristaltic)
Flow Rate Range1–100 mL/min
Self-Priming Height3 mWg
Maximum Discharge Pressure6 bar
Ingress Protection RatingIP65
Operating Temperature (Liquid)5–80 °C
Operating Temperature (Ambient)5–40 °C
Fluid Viscosity Limit≤150 cSt
Accuracy±2% of setpoint (1–100% range)
Repeatability±1%
Weight1.5 kg
Dimensions (L×H×W)134 × 93 × 145 mm
Power Supply99–264 VAC, 50–60 Hz
Analog Control Inputs0–5 V, 0–10 V, 0–20 mA, 4–20 mA
Digital InterfaceRS232
Dry-Run CapableYes
Materials (Standard Configuration)Pump Head – PP, Diaphragm – PTFE-coated, Valves – FFKM
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelKDS100
Instrument TypeSyringe Pump
Flow Rate Range0.1 µL/hr – 423 mL/hr (dependent on syringe size)
Stepper Motor Resolution0.529 µm per half-step
Maximum Linear Force9 kg
Accuracy±<1%
Repeatability±0.1%
DisplayReal-time volume and flow rate
Control InterfaceMenu-driven keypad
MemoryNon-volatile parameter retention
Optional ConnectivityRS-232 (KDS-200+ models only)
Syringe Capacity Range10 µL – 60 mL
Dimensions (W×D×H)23 × 15 × 13 cm
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTruelab
OriginShanghai, China
Model VariantsBT-100, BT-100B, BT-100D, BT-100SD, BT-200B, BT-200D, BT-200SD, D100B, D200B, BT-1FJ, BT-4F, BT-100-4, BT-100-8
Flow Rate Range0.3–27,000 mL/h (model-dependent)
Maximum Output Pressure≥2.0–3.0 kg/cm²
Speed Control0–155 rpm (digital display, stepless adjustment)
Channel Configuration1–8 independent channels
Timing FunctionRun/Standby timer from 1 sec to 9 h 59 min 59 sec
Communication InterfaceRS232 (BT-100SD & select models)
Drive TechnologyMicrocontroller-based细分 drive circuitry for low noise and stable operation
ComplianceDesigned for general laboratory fluid handling per ISO 8573-1 (compressed air purity class not applicable), compatible with GLP/GMP environments when integrated into validated systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKNF
OriginGermany
ModelSIMDOS FEM1.02
Flow Rate Range0.03–20 mL/min
Self-Priming Height2 mWg
Maximum Discharge Pressure6 bar
Ingress ProtectionIP65
Operating Temperature (Liquid)5–80 °C
Operating Temperature (Ambient)5–40 °C
Power Supply99–264 VAC, 50–60 Hz
Control OptionsManual, Analog (0–5 V / 0–10 V / 0–20 mA / 4–20 mA), RS232 Interface
Pump Head / Diaphragm / Valve Material OptionsPP/PTFE-coated/FFKM
Dimensions (L×H×W)143 × 93 × 145 mm
Weight0.9 kg
Accuracy±2% of setpoint (1–100% range)
Repeatability±1%
Max. Fluid Viscosity150 cSt
Dry-Run CapableYes
Duty CycleContinuous (24/7)
Show next