| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | FarinoGraph E-300 |
| Compliance | ISO 5530-1, ISO 5530-2, AACCI 54-22.01, ICC 114/1, GB/T 14614, DIN EN ISO 5530-1 |
| Torque Range | Up to 28 N·m |
| Measurement Duration | 0–200 min |
| Power Supply | 230 V (184–264 V) / 50–60 Hz, 1 kW or 115 V (88–126 V) / 50–60 Hz, 1 kW |
| Dimensions (W×H×D) | 430 × 630 × 740 mm |
| Weight (without mixer) | 56 kg |
| Weight (with S300 mixer) | 74 kg |
| Interfaces | 4× USB, 1× HDMI, 2× Ethernet |
| Software | MetaBridge v3.x with AI-assisted curve interpretation and audit-trail-enabled data management |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SmartFiber-E |
| Price | USD 5,600 (FOB Shanghai) |
| Compliance | GB/T 5009.88–2008, GB/T 5413.6–2010, GB/T 9822–2008, GB/T 22494–2008, NY/T 1594–2008, AOAC 991.43, AACC 32–07, NMKL 157, ASP Method |
| Sample Throughput | 6 samples per run |
| Filtration Technology | Dual-mode SmartVacuumFilter™ with alternating positive/negative pressure |
| Crucible Type | Patented ground-glass fritted crucibles (G2, 40–100 µm pore size) |
| Filtration Speed | ≤3 min per 100 mL digestate |
| Precision | RSD <0.5% (n=6, certified reference material) |
| Software | Standalone control interface with audit trail logging |
| Accessories | G1–G5 fritted crucibles, 80–2800 mesh sieves, optional thermostatic shaker bath, standardized clamp kits |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Viscograph-E |
| Price | USD 135,000 (FOB Hamburg) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Model | Extensograph |
| Sample Mass | 300 g flour + 6 g salt + distilled water |
| Dough Kneading Speed | 83 ±3 rpm |
| Resting Time | 15 ±1 min |
| Stretching Speed | 14.5 ±0.5 mm/s |
| Maximum Extension Length | 680 mm |
| Measurement Range | 0–2,000 EU/BU |
| Fermentation Temperature Control | 30 °C (adjustable, with ambient compensation up to 40 °C) |
| Humidity Control | Ultrasonic humidification system |
| Dimensions (W × H × D) | 840 × 720 × 500 mm |
| Weight | ~115 kg |
| Power Supply | 100–240 V, 50/60 Hz, 0.24 kW |
| Interfaces | USB (4), LAN/Ethernet (2), HDMI (1) |
| Compliance Standards | ISO 5530-2, DIN EN ISO 5530-2, CEN EN ISO 5530-2, AACC 54-10.01, ICC Standard 114/1, GB/T 14615, GB/T 35994, NF V03-717-2, OENORM EN ISO 5530-2, SN EN ISO 5530-2, BS EN ISO 5530-2, UNE-EN ISO 5530-2, IRAM 15856, TCVN 7848-2, AGSA 06-01, CCAT 03 & 16 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EAB1-2000 / EAB1-95 |
| Price | USD 1,020 (FOB Shanghai) |
| Instrument Category | Aflatoxin B1 Quantification System |
| Detection Principle | Solid-Phase Enzyme-Linked Immunosorbent Assay (ELISA) |
| Wavelength | 450 ± 2 nm (standard interference filter) |
| Absorbance Range | –0.041 to 1.999 A |
| Detection Limit | 0.1 ng/mL |
| Quantitative Range | 0.1–1.0 ng/mL (ppb) |
| Sensitivity | < 0.1 ng/mL |
| Accuracy | ±0.1 ng/mL |
| Throughput | 20 samples/hour |
| Light Source | LED (3.6 V / 20 mA) |
| Operating Environment | 5–35 °C, ≤85% RH |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (EAB1-95) | 350 × 270 × 210 mm |
| Weight (EAB1-95) | 9 kg |
| Dimensions (EAB1-2000) | 410 × 264 × 110 mm |
| Weight (EAB1-2000) | 10 kg |
| Power Consumption | 37 W (EAB1-95), 40 W (EAB1-2000) |
| Transmittance Stability (EAB1-2000) | ≤0.3% T/5 min (bright), ≤0.2% T/5 min (dark) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Pawkit |
| Price Range | USD 1,400–7,000 (est.) |
| Sensor Type | Capacitive Hygrometric Sensor |
| Accuracy | ±0.02 aw |
| Resolution | ±0.01 aw |
| Measurement Range | 0.00–1.00 aw |
| Repeatability | ±0.01 aw (typical, per AOAC 978.17) |
| Sample Cup Volume | 7 mL (max. 15 mL) |
| Measurement Time | < 5 min |
| Display | 6-digit custom LCD (3-digit aw + 3-digit °C) |
| Dimensions | 6.6 × 10.7 × 2.0 cm |
| Weight | 115 g |
| Power Supply | Two 3 V CR2032 lithium coin cells (3-year typical service life) |
| Operating Environment | 4–60 °C |
| Certifications | CE Marked |
| Warranty | 1 year parts & labor (extendable) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | 4TE DUO |
| Sensor Type | Mirror Condensation Dew Point Sensor |
| Accuracy (aw) | ±0.003 aw |
| Resolution (aw) | ±0.0001 aw |
| Measurement Range (aw) | 0.1000–0.9500 aw |
| Repeatability (aw) | ±0.001 aw |
| Moisture Content Resolution | ±0.01% |
| Moisture Content Repeatability | ±0.02% |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 readings |
| Display | 128×64 pixel backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 VAC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |
| Brand | Aqualab / METER Group |
|---|---|
| Origin | USA |
| Model | AquaLab Pre |
| Sensor Type | Mirror Condensation Dew Point (Standard), Capacitance (Optional) |
| Accuracy | ±0.01 aw (Dew Point), ±0.015 aw (Capacitance) |
| Resolution | 0.001 aw |
| Measurement Range | 0.05–1.000 aw |
| Repeatability | ≤ ±0.002 aw |
| Temperature Control | Fixed at 25.0 °C (±0.2 °C stability) |
| Temp. Resolution | 0.1 °C |
| Sample Volume | 7 mL recommended (max 15 mL) |
| Measurement Time | < 5 minutes |
| Display | 20-character alphanumeric backlit LCD |
| Interface | RS-232, USB |
| Dimensions | 24.1 × 22.9 × 8.9 cm |
| Weight | 3.2 kg |
| Power | 110–220 VAC, 50/60 Hz, < 0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 978.18 |
| Warranty | 1 year parts and labor |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | Aqualab 4TE |
| Sensor Principle | Mirror Condensation Dew Point |
| Accuracy | ±0.003 aw |
| Resolution | 0.0001 aw |
| Measurement Range | 0.030–1.000 aw |
| Repeatability | ±0.001 aw |
| Temperature Control Range | 15–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Sample Volume | 7 mL (max 15 mL) |
| Measurement Time | <5 min (avg. 2.5 min) |
| Data Storage Capacity | 8,000 secure readings with timestamp, user ID, and calibration logs |
| User Accounts | Up to 25 configurable usernames/passwords |
| Interface | RS-232, USB |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 26.7 × 17.8 × 12.7 cm |
| Weight | 3.18 kg |
| Power | 110–220 V AC, 50/60 Hz, <0.4 A |
| Operating Environment | 4–60 °C, 0–90% RH (non-condensing) |
| Certifications | CE, AOAC Official Method 975.13, FDA 21 CFR Part 11 compliant (audit trail, electronic signature support) |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AquaLab VSA |
| Price Range | USD 25,000 – 62,500 (converted at ~¥200,000–¥500,000) |
| Measurement Principle | Mirror Condensation Dew Point |
| Isotherm Methods | Dynamic Dew-point Isotherm (DDI) & Dynamic Vapor Sorption (DVS) |
| Accuracy | ±0.005 aw |
| Resolution | ±0.001 aw |
| aw Range | 0.030–0.950 |
| Repeatability | ±0.003 aw |
| Temperature Control | 10–60 °C (STP adjustable) |
| Temp Stability | ±0.1 °C |
| Max Operating Pressure | ≤7 psi |
| Sample Mass Range | 500–5000 mg |
| Mass Resolution | ±0.1 mg |
| Sample Cup Volume | 7.5 mL (recommended), up to 15 mL |
| Water Reservoir Volume | 7 mL (max 15 mL) |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 25.4×38.1×30.5 cm |
| Enclosure | Machined aluminum frame with flame-retardant silicone resin |
| Weight | 14.97 kg |
| Power | 110–220 V AC, 50/60 Hz |
| Operating Environment | 4–60 °C, 10–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |