Empowering Scientific Discovery

Shanghai Renhe Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
ModelCM-2300d
Instrument TypePortable
Optical Geometry0/45° integrating sphere
Light SourceDual pulsed xenon lamps
Spectral Range360 nm to 740 nm
Wavelength Interval10 nm
Spectral Bandwidth~10 nm
Reflectance Range0–175%
Display Resolution0.01%
Measurement Time~1.5 s (SCI & SCE simultaneously)
RepeatabilityΔE*ab ≤ 0.08 (after white calibration, 30 measurements at 10 s intervals)
Inter-instrument AgreementΔE*ab ≤ 0.4 (SCI, based on BCRA Series II standards)
Measuring/Aperture AreaØ8 mm / Ø11 mm
Weight670 g (without batteries)
Data Storage Capacity1,700 sets (each set includes paired SCI/SCE data)
ComplianceCIE No. 15, ISO 7724-1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYi Heng (Shanghai)
OriginShanghai, China
ModelDHP Series
Temperature RangeRT+5°C to 65°C
Temperature Resolution0.1°C
Temperature Uniformity±1.5°C (at 37°C, horizontal models) / ±2.0°C (at 37°C, vertical models)
Temperature Fluctuation±0.5°C
Power Input200–2200 W (model-dependent)
Chamber Volume16–1000 L
Interior Dimensions (W×D×H, mm)250×260×250 to 890×740×1590
Exterior Dimensions (W×D×H, mm)530×480×420 to 1050×880×2060
Standard Shelving2–4 stainless steel trays
Display TypeLED (standard) / LCD (B-series)
Optional FeaturesUV sterilization module, programmable multi-segment controller (7 programs × 9 steps), RS485 interface, thermal printer output, independent over-temperature cut-off alarm, auto-fan speed modulation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ModelMobile LAB
Vehicle IntegrationCustom Chassis Options
Power SupplyDual-mode (110/240 V AC + Rechargeable Battery)
Environmental ControlIndependent HVAC with 20 air changes/hour
SafetySeismic-grade instrument mounting, anti-slip flooring, fire extinguisher, dedicated waste/fresh water tanks
Data InfrastructureIntegrated LAN, optional GPS, printer, and PC
ComplianceDesigned for ASTM D975, D3948, D4865, EN 590, ISO 4214, and USP <1058> analytical instrument qualification frameworks
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcchio
OriginBelgium
ModelSCAN Series
Particle Size Range10 µm – 50 mm (extendable to 2 µm – 20 cm)
Optical ResolutionUp to 600 Mpx (Scan 700)
IlluminationBroadband white light (350–640 nm), transmission + reflection modes
Imaging SensorHigh-speed CCD linear array
SoftwareCallisto 2D/3D
DispersionDry-mode linear disperser with anti-adhesion metal coating
Sample Stage242 × 320 mm (Scan 700)
ComplianceASTM D7927, ISO 9276-6, USP <1788>, GLP-ready audit trail in Callisto
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMEMMERT
OriginGermany
ModelWNB22
Instrument TypeCirculating Water Bath
Internal Volume22 L
Temperature Range10 °C to 95 °C (with optional boiling mode at 100 °C)
Temperature Stability±0.1 °C (typical, at 37 °C, load-free)
Temperature Resolution & Setpoint Accuracy0.1 °C
Control SystemPID with self-diagnostic function
SensorDual 4-wire Pt100 (E-type), single 4-wire Pt100 (B-type)
Overtemperature ProtectionTriple-stage (E-type) / Dual-stage (B-type)
Timer RangeB-type: 1 min – 99 h 59 min
E-type1 min – 999 h
Power Rating2000 W
ConstructionStainless steel inner bath and outer housing (AISI 304)
CertificationsCE, tested to IEC 61010-1 for laboratory safety
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
Instrument TypePortable
Optical Geometryd/8° integrating sphere
Light SourcePulsed Xenon Lamp
Spectral RangeY Reflectance 0.01–160.00%
RepeatabilityΔE*ab ≤ 0.07 (std. dev., white calibration, 30 measurements at 10 s intervals)
Measurement ApertureØ50 mm / Illumination Area: Ø53 mm
Measurement Time1 s
Minimum Interval3 s
Battery Life~800 measurements (AAA alkaline/Ni-MH, Konica Minolta specified conditions)
DisplayBacklit dot-matrix LCD (15×9 characters + icon line), 6 language options (EN/DE/FR/IT/ES/JP)
Data Storage1,000 measurements (instrument-only)
Standard CalibrationCR-A44 white calibration tile
ComplianceCIE 1931 2° standard observer, CIE No. 15:2004, ISO 7724-1, ASTM E308, JIS Z 8722
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelEUROSTAR 60 digital
Stirrer TypeElectric Overhead Stirrer
Max. Mixing Volume (H₂O)40 L
Speed Range0/30–2000 rpm
Motor Output Power126 W
Max. Torque60 N·cm
Speed ControlContinuous (Stepless)
Speed DisplayLED, 7-segment
Speed Accuracy±1 rpm (n > 300 rpm), ±3 rpm (n < 300 rpm)
Speed Deviation±1% (n > 300 rpm)
Max. Viscosity50,000 mPa·s
Shaft Clamping Range0.5–10 mm
Hollow Shaft ID11 mm
Dimensions (W×H×D)86 × 248 × 208 mm
Weight4.4 kg
IP RatingIP42
Operating Temperature5–40 °C
Relative Humidity≤80 %
Motor TypeBrushless DC
Continuous Duty Cycle100 %
Input Voltage230 / 115 / 100 V
Frequency50/60 Hz
Input Power176 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Yiheng
OriginShanghai, China
ModelBW-12 / BWS-12 / BW-27 / BWS-27 (with magnetic drive pump)
Temperature RangeRT+5°C to 100°C (BW series), RT+5°C to 80°C (BWS series)
Temperature Stability±0.2°C
Resolution0.1°C
Effective Volume11 L (BW-12/BWS-12), 20 L (BW-27/BWS-27)
Inner Tank Dimensions300×240×200 mm (BW-12/BWS-12), 500×300×200 mm (BW-27/BWS-27)
Power SupplyAC 220 V, 50 Hz
Heating Power800 W (BW-12), 1000 W (BWS-12 & BWS-27)
Timer Range0–9999 min
Circulation TypeInternal recirculation only
Control ModeHeating-only PID temperature regulation
Safety FeaturesIndependent dry-run protection, dual-limit overtemperature cutoff
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelAurora-6
QuotationUpon Request
Cavity GradeIndustrial-Grade
Sample Capacity16–40 vessels
Microwave SourceDual Magnetron System
Max Temperature500 °C
Max Pressure15 MPa
Cavity Material316L Stainless Steel
Power Input220–240 V / 50 Hz, 16 A
Installed Power3200 W
Microwave Frequency2450 MHz
Output ModeNon-pulsed Continuous Microwave
Power Control Accuracy±1 W
Control AlgorithmHigh-Frequency Closed-Loop PID
Display7-inch HD Color Touchscreen
Cooling SystemTwin-Air Dual-Direction Forced Air Cooling with Optimized Duct Design
Operating Ambient5–40 °C, 15–80% RH
Dimensions (H×W×D)665 × 546 × 590 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrabner
OriginAustria
ModelMINITEST FFK
Test PrincipleCorrosion-Resistant Capillary Extrusion (DIN 51805)
Temperature Range−50 °C to +30 °C
Temp. Accuracy±0.1 °C
Pressure Range0–300 kPa
Pressure Accuracy±0.1 kPa
Dimensions196 × 315 × 175 mm
Weight10 kg
Power Supply100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFieldLab 58
Product TypePortable Instrument
Detection CapabilitiesElemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination
Power SupplyRechargeable Lithium-ion Battery
Dimensions487.68 × 386.08 × 228.6 mm (L × W × H)
ComplianceASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelQuintix213-1CN (210 g / 1 mg, internal calibration)
Max Capacity210 g
Readability1 mg
Repeatability1 mg
Linearity2 mg
Stabilization Time1.5 s
Pan Diameter120 mm
Chamber Height209 mm
Dimensions (W × D × H)216 × 360 × 320 mm
Weight~4.9 kg
Power Supply100–240 V AC
InterfaceminiUSB
ComplianceISO/IEC 17025 traceable calibration, GLP/GMP-compliant print output, CMC certification (China), ISO CAL automatic internal adjustment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYiHeng (Shanghai Yi Heng)
OriginShanghai, China
ModelBPHJS Series
Temperature Range−60 °C to +130 °C
Humidity Range30–95 %RH
Temperature Uniformity±2 °C
Temperature Fluctuation±0.5 °C
Humidity Fluctuation±3 %RH
RefrigerantR134a (ozone-friendly)
Inner Chamber MaterialAISI 304 mirror-finish stainless steel
Control SystemColor TFT touchscreen with programmable logic (120 programs × 99 segments, up to 999 cycles)
Communication InterfaceRS-232/RS-485, USB data export (SD card), optional 485 printer interface
Safety ProtectionsIndependent over-temperature cutoff, compressor overheat/overcurrent/overload protection, fan overheat protection, low-water alarm
Power SupplyAC 380 V, 50 Hz (models with −40 °C or −60 °C capability)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMICCRA
OriginGermany
ModelDS-20 (Stator Outer Diameter: 20 mm)
Rotor Outer Diameter15 mm
Maximum Tip Speed30.6 m/s
Probe Length250 mm
Minimum Immersion Depth200 mm / 40 mm (depending on configuration)
Recommended Sample Volume (Water)20–5,000 mL
Rotor-Stator ConfigurationShear-Mixing, Emulsification, or Multi-Function
Stator TypesCoarse, Fine, Fine-Pin, and Micro-Structured
Rotor TypesShear-Mixing, Emulsification, or Dual-Function
CompatibilityPaste, Fibrous, and Liquid Matrices
Modular Quick-Change SystemYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandILMVAC
OriginGermany
Model2567C-50
Pump TypeOil-Free Reciprocating Piston Vacuum Pump
Pumping Speed4.9 m³/h (82 L/min)
Ultimate Vacuum<80 mbar (abs)
Motor Power250 W
Dimensions (L×W×H)381×254×254 mm
Weight7.5 kg
Exhaust Port Diameter7 mm
Noise Level≤52 dB(A)
Duty CycleContinuous Operation Rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUM
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLUMiFrac
QuotationUpon Request
PrincipleCentrifugal Fracture Testing (Dynamic Load Application via Rotating Rotor)
Max. Centrifugal Force Range0.1 N – 6.5 kN
Rotational Speed Range100 – 13,000 rpm
Tensile Strength Measurement Rangeup to 80 MPa
Sample Capacity8 parallel specimens
Sample Dimensionsmax. 30 × 30 × >1 mm³
Bonded Area Diameter7 mm, 10 mm or custom
Bonded Surface Materialsmetallic & non-metallic substrates
Specimen Mass Range4.1 g – 38.7 g (Cu/W-based reference: ~58 g)
Temperature Control Range−11 °C to +40 °C
Measurement Duration1 min – 99 h
ComplianceISO 4624, DIN EN 15870, DIN EN 14869-2, JIS K 5600-5-7
Data InterfaceUSB
Power Supply100/120/230 V, 50/60 Hz
Max. Power Consumption1050 W
Net Weight56 kg
Dimensions (W×H×D)380 × 296 × 640 mm³
Software PlatformSEPView® v6.x with real-time critical force calculation, statistical comparison, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKUDOS
OriginShanghai, China
Model SeriesSK-12C / SK-18C / SK-24C / SK-36C
Tank Capacity26 L / 54 L / 90 L / 123 L
Ultrasonic Frequency25 kHz
Ultrasonic Power Output500 W / 750 W / 1000 W / 1500 W
Power Adjustment Range40–100% in 1% increments
Timer Range1–99 minutes
Tank Material304 Stainless Steel
Drain ValveIntegrated 304 stainless steel valve
Transducer Count12 / 18 / 24 / 36
External Dimensions (W×D×H)44×45×52 cm / 48×54×63 cm / 61×60×77 cm / 90×70×82 cm
Internal Tank Dimensions (W×D×H)38×28×25 cm / 42×37×35 cm / 54×41×41 cm / 83×53×28 cm
Instrument TypeGeneral-purpose ultrasonic cleaner
Regulatory ClassificationDomestic-manufactured laboratory equipment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJEIO TECH
OriginSouth Korea
ModelMSA-0420
Stirrer TypeElectric Overhead Stirrer
Max. Mixing Volume20 L
Speed Range80–2000 rpm
Torque19 N·cm
Max. Viscosity Handling10,000 cP (at 1200 rpm)
Temperature Control Range5–40 °C
MotorBrushless DC
Power Input/Output70 W / 40 W
Chuck Capacity3–10 mm
Housing MaterialAnodized Aluminum Body with PP Components
Dimensions (W×H×D)75 × 215 × 150 mm
Net Weight2.8 kg
Protection ClassIP30 (DIN EN 60529)
Operating Ambient5–40 °C, ≤80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelCaptair 834 Smart
Airflow Capacity220 m³/h
Dimensions (L×W×H)900 × 530 × 2138–2323 mm
Voltage/Frequency100–240 V AC / 50–60 Hz (Internal Circuit: 24 V DC)
Cabinet MaterialChemically resistant polypropylene (transparent front panels) + galvanized steel coated with acid-resistant polymer
Filter Frame MaterialPolypropylene (PP)
Filtration TechnologyPatented modular dual-layer filter system (primary + safety filter)
Safety AlarmsLED status band + audible tone coding for fan failure, face velocity deviation, or filter saturation
ComplianceAFNOR NF X 15-211:2009 (FR), SEFA 9 (US), BS 7989 (UK), DIN 12927 (DE), JG/T 385–2012 (CN), EN 1822:1998 (HEPA H14/ULPA U17)
Filter EfficiencyResidual chemical concentration < 1% of OSHA TWA or ACGIH TLV thresholds
Filter Saturation DetectionMolecode® S (organics), A (inorganics), F (formaldehyde)
Certified Test ReportsTÜV SGS (SEFA 9), Intertek (NF X 15-211), Tongji University (JG/T 385–2012)
SecurityDual-point mechanical lock
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLISICO
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelLS-1
Price RangeUSD 14,000 – 70,000
Instrument TypeLow-Field TD-NMR Analyzer
Sample TypeSolid–Liquid Suspensions
Magnet TypeSamarium–Cobalt Permanent Magnet
Static Field Strength0.165 ± 0.01 T
Larmor Frequency7.0 ± 0.3 MHz
Frequency Tuning Range1–75 MHz
Pulse Sequences SupportedFID, Spin Echo (SE), CPMG, Saturation Recovery T₁ (Sat_T1)
Relaxation Time Range0.1 ms – 10 s
Probe Inner Diameter20 mm
Sample Volume1–5 mL
Measurement Repeatability±2%
Frequency Resolution0.28 Hz
Phase Accuracy0.09°
Timing Resolution13.3 ns
Sampling Rate75 MS/s
Maximum Acquisition Bandwidth10 MHz
Minimum Echo Spacing150 µs
Maximum Echo Train Length60,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
Modelarium® 611 VF
Dimensions (W×H×D)30.2 × 11.3 × 15.7 cm
Unit Weight17.4 kg
Operating Weight26.4 kg
Resistivity18.2 MΩ·cm at 25 °C
Total Organic Carbon (TOC)<1 ppb
Endotoxins<0.001 EU/mL
Particles<1 particle/mL @ ≥0.2 µm
Microbial Contamination<1 CFU/mL
Flow Rate1.5 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelG20S
Instrument TypeGeneral-purpose Potentiometric Titrator
Measurement Range±2000 mV / pH –26.0 to 40.0
Meter Accuracy0.01%
Meter Resolution0.1 mV / 0.001 pH
Titration Precision0.2 mV / 0.003 pH
Built-in StirrerPropeller-type
Endpoint DetectionYes
GLP-Compliant ReportingYes
Preloaded Methods>20
Max. Samples per Series120
USB ConnectivityYes
RFID-enabled Smart BurettesYes
LabX Express Software IntegrationYes
Optional Rondolino AutosamplerYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSartorius
OriginGermany
ModelBSA423S-CW
TypePrecision Balance
Maximum Capacity420 g
Readability1 mg
Repeatability≤1 mg
Linearity≤1 mg
CalibrationMotorized Internal Calibration
Pan Size115 × 120 mm
DisplayBacklit High-Contrast LCD, 15 mm Character Height
InterfaceRS-232C Bidirectional
Operating Languages5 (English, German, French, Spanish, Chinese)
ComplianceISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible via optional software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXAKT
OriginGermany
Model80Eplus
Instrument TypeThree-Roll Mill
Sample CompatibilitySoft, paste-like, and viscous materials (e.g., inks, paints, cosmetics, battery slurries)
Feed Particle Size5–180 µm
Final Output Particle Size≤1 µm
Minimum Achievable Gap5 µm
Maximum Line Pressure26 N/mm (gap-dependent)
Throughput at 10 µm Gap10 mL–18 L/hr
Roller Surface OptionsChrome-plated steel, tungsten carbide, aluminum oxide, or silicon carbide
Dimensions (W × D × H)591 × 608 × 602 mm
Installed Footprint Recommendation (W × D)1200 × 700 mm
Weight112–125 kg
Cooling Interface10 mm inlet / 13 mm outlet
Max Inlet Coolant Temperature55 °C
Operating Ambient Temperature10–30 °C
Power Supply Option 13 × 380–420 V / 50–60 Hz, 1300 W
Power Supply Option 23 × 200–240 V / 50–60 Hz, 1300 W
Control Interface8.4″ color TFT touchscreen with real-time parameter logging (gap, torque, roller temperature, motor power, time stamp)