| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Test Principle | Corrosion-Resistant Capillary Extrusion (DIN 51805) |
| Temperature Range | −50 °C to +30 °C |
| Temp. Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58 |
| Product Type | Portable Instrument |
| Detection Capabilities | Elemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 487.68 × 386.08 × 228.6 mm (L × W × H) |
| Compliance | ASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIDIS ADXpert |
| Test Pressure | Atmospheric (0 kPa gauge) |
| Temperature Range | 0–400 °C (32–752 °F) |
| Temperature Accuracy | ±0.1 °C |
| Distillation Time (Gasoline) | 15 min |
| Sample Volume | 6 mL |
| Residue Measurement | Integrated analytical balance (±0.003 g) |
| Predefined Methods | 10 (ASTM D86 Group 0–4, ASTM D7344, ISO 3045, IP 123) |
| Cleaning Volume per Cycle | 4 mL (acetone) |
| Dimensions (W×H×D) | 200 × 320 × 220 mm |
| Weight | 13 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W or 12 V DC (optional vehicle battery) |
| Brand | Renhe |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | MOBILE FUEL LAB |
| Pricing | Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | LaserNet 200 Series |
| Type | Portable Instrument |
| Detection Parameters | Particle Counting, Ferrous Particle Concentration & Count (>25 µm), Morphological Wear Debris Classification, Free Water (ppm), Bubble/Contaminant Discrimination |
| Standards Compliance | ASTM D7596, ISO 4406, NAS1638, SAE AS4059, ASTM D6786, ISO 11171 |
| Imaging Technology | Direct High-Resolution CCD Imaging with Laser Illumination |
| Particle Size Range | ≥2 µm (morphology-resolved), ≥20 µm (automated classification), ≥25 µm (ferrous count) |
| Max Sample Contamination Tolerance | 5,000,000 particles/mL |
| Max Soot Tolerance | 2% w/w |
| Auto-Gain Control (AGC) | Yes |
| Onboard Data Management | Asset Tracking, Trend Analysis, Custom Cleanliness Thresholds |
| Dimensions | 35.6 cm H × 36.8 cm W × 78.7 cm D |
| Weight | 8.5 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | NOACK |
| Standard Compliance | ASTM D5800, DIN 51581 |
| Temperature Range | 150–350 °C (±0.1 °C accuracy) |
| Heating Medium Options | Aluminum block (non-Wood’s alloy) or Wood’s alloy bath |
| Power Supply | 230 V, 50 Hz, 5.8 A |
| Dimensions (K44090) | 59 × 35 × 68 cm |
| Weight (K44090) | 26.7 kg |
| Dimensions (K44091) | 54 × 38 × 37 cm |
| Weight (K44091 with accessories) | 38.2 kg |
| Sample Mass | 65 g |
| Test Duration | 60 min at specified temperature |
| Air Flow Control | Manual (incl. inclined-tube manometer, 0–30 mm H₂O) or optional automated pressure regulation |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K39495 |
| Temperature Range | 25–84 °C |
| Temp. Stability | ±0.05 °C |
| Stirring Speed | 0–2000 rpm |
| Stirring Accuracy | ±1 rpm |
| Simultaneous Test Capacity | 7 × 100 mL samples |
| Bath Medium | Water or white mineral oil |
| Bath Volume | 15.15 L |
| Power Supply | 220–240 V / 50 Hz / 12 A |
| Dimensions (W×D×H) | 52.7 × 38.75 × 74.9 cm |
| Heating Power | 75 W (1/10 hp) |
| Bath Material | Transparent polycarbonate (25.5 × 28 × 24 cm) |
| Standards Compliance | ASTM D1401, D6074, D6158 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK35100 |
| Sample Capacity | 6 |
| Temperature Range | 51.7–399 °C |
| Temperature Stability | ±0.5 °C (±1 °F) |
| Maximum Air Flow Rate | 10 L/h |
| Power Supply | 220–240 V, 50/60 Hz, Single-Phase, 15.9 A |
| Dimensions | 83 × 37 × 105 cm |
| Weight | 122.9 kg |
| Compliance | ASTM D4636, D5968, D6594 |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | SpectrOil M/C-W |
| Compliance | ASTM D6595 |
| Detection Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Elements Analyzed | Up to 32 elements per run (default 24) |
| Analysis Time | ≤30 seconds per sample |
| Optical System | High-Resolution CCD Spectrometer |
| Sample Preparation | None required |
| Operating Environment | Benchtop, no inert gas or auxiliary utilities needed |
| Software Platform | Windows-based instrument control and data management suite with optional grease, sulfur, and coolant analysis modules |
| Certification | JOAP (Joint Oil Analysis Program) Qualified |
| Dimensions | 77.5 cm (H) × 63.5 cm (W) × 70 cm (D) |
| Weight | ~114 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K26210-3 |
| Standard Compliance | ASTM D6082 |
| Test Temperature | 150 °C |
| Temperature Uniformity | ±0.5 °C |
| Bath Volume | 38.5 L |
| Air Flow Rate | 200 mL/min |
| Power Supply | 220–240 V, 50 Hz |
| Dimensions (W×D×H) | 82 × 38 × 79.4 cm |
| Weight | 28.1 kg |
| Heating System | Immersed copper heater with PID-controlled microprocessor |
| Temperature Display | Dual LED, selectable ℃/°F |
| Construction | Steel base with chemical-resistant polyimide enamel coating |
| Includes | Two 1000 mL calibrated test cylinders, two calibrated antifoam heads, two air inlet tubes, two exhaust tubes, two rubber stoppers, one bath tank, one support stand |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18200 Series Oxidation Stability Tester |
| Standards Compliance | ASTM D2112, D2272, D4742 |
| Operating Pressure | 90 psi (620 kPa) initial, up to 500 psi (3450 kPa) burst rating |
| Temperature Range | Ambient to 200 °C |
| Control Stability | ±0.02 °C |
| Rotation Speed | 100 rpm ± 1 rpm |
| Bath Capacity | 68 L (2-cell), 95 L (3-cell), 121 L (4-cell) |
| Heating Power | 0–2750 W (2/3-cell), 0–3750 W (4-cell) |
| Drive Motor | 0.5 hp continuous-duty, spherical bearing, integrated gear reduction |
| Bearing Type | PTFE-coated carbon fluoropolymer |
| Pressure Sensing | Direct-mount transducer on oxygen bomb |
| Safety | Auto-shutdown at >177 °C or >16.7 °C above setpoint |
| Software | Oxidata™ v5.x (Windows-based, FDA 21 CFR Part 11–ready audit trail, GLP-compliant data archiving) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K50119 |
| Test Plate Temperature Range | Up to 400 °C |
| Sample Oil Temperature Range | Up to 210 °C |
| Spray Speed | 0–1800 rpm (digital display) |
| Timer Range | 0–99.9 hours (adjustable countdown) |
| Acid Gas Flow Rate | 0.2–1.0 L/h |
| Oil Capacity | 0.35 L |
| Power Supply | 220–240 V, 50/60 Hz, 5 A |
| Test System Dimensions | 81 × 46 × 53 cm, 22.7 kg |
| Control Unit Dimensions | 46 × 30 × 46 cm, 11.3 kg |
| Temperature Display Units | °C or °F selectable |
| Compliance | FTM 791-3462 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | FK12190 |
| Sample Capacity | 6 positions |
| Test Temperature Range | Ambient to 127 °C |
| Bath Medium | 9.5 L white mineral oil |
| Temperature Control Accuracy | ±0.5 °C at 110 °C |
| Air Flow Rate | 1.0 ±0.1 L/h (independent flowmeter & control valve) |
| Stirring Motor | 1/20 hp recirculating agitator |
| Compliance | ASTM D2440, D4636, D5968, D6594 |
| Display | Dual-scale digital LED (°C/°F), real-time and setpoint |
| Safety | Over-temperature cut-off with automatic power disconnection |
| Brand | ShenKai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A5 Auto |
| Application | Diesel Cetane Number Determination |
| Principle | Engine Method (Motor Method) |
| Configuration | Benchtop |
| Standards Compliance | GB/T 386–2010, ASTM D613–08 |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.3 mm |
| Displacement | 0.61 L |
| Compression Ratio Range | 8:1 to 36:1 (motor-driven, computer-controlled) |
| Engine Speed | 900 ± 9 rpm |
| Injection Timing | 13° BTDC |
| Injector Opening Pressure | 10.30 ± 0.34 MPa |
| Fuel Flow Rate | 13.0 ± 0.2 mL/min |
| Injector Cooling Temperature | 38 ± 3 °C |
| Intake Air Temperature | 66 ± 0.5 °C |
| Jacket Coolant Temperature | 100 ± 2 °C |
| Lubricating Oil Pressure | 172–207 kPa |
| Lubricating Oil Temperature | 57 ± 8 °C |
| Base Compression Pressure | 3275 ± 138 kPa |
| Crankcase Vacuum | 0.25–1.5 kPa |
| Fuel Reservoir Elevation | 635 ± 25 mm above pump inlet centerline |
| Power Supply | 380 V, 50 Hz, Grounded |
| Total Installed Power | 19 kW (12 kW main unit + 7 kW auxiliary chiller) |
| Dimensions (W×D×H) | 1550 × 900 × 1720 mm |
| Weight | 1200 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18650 |
| Standard Compliance | ASTM D5074, STP512A L-60-1 (formerly CRC L-60), FTM 791-2504 |
| Test Temperature | 162.8 ± 0.6 °C |
| Air Flow Rate | 1.1 L/h |
| Drive Speed | 1725 rpm |
| Load | 128 W |
| Power Supply | 220–240 V, 50 Hz, single-phase, 15 A |
| Dimensions (Test Chamber) | 61 × 61 × 37 cm |
| Dimensions (Control Cabinet) | 60 × 60 × 44 cm |
| Weight | 149.7 kg |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LS-U |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur |
| Measurement Range | 0.1 mg/L to >10,000 mg/L (0.2 ppm to >1% w/w) |
| Accuracy | ±0.1 mg/L (for 0.1 ≤ X < 1.0 mg/L) |
| Sample Volume | 5–50 µL (liquid) |
| Carrier Gas | Ultra-high-purity Argon (99.999%) and Oxygen (99.999%) |
| Furnace Temperature Range | Ambient to 1150 °C ±2 °C |
| Operating Environment | 5–30 °C, stable ambient conditions |
| Power Supply | 220 V ±10%, 50 Hz, 3 kW (15 A) |
| Software Interface | Switchable Chinese/English GUI |
| Compliance Standards | SH/T 0689, ASTM D5453, ASTM D4629, ASTM D5762 |
| Data Management | LIMS-ready architecture with audit trail capability |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FDM 6000 Series |
| Product Type | Portable Instrument |
| Detection Parameter | Fuel Dilution in Engine Oil |
| Detection Principle | Surface Acoustic Wave (SAW) Sensor + Headspace Vapor Analysis per Henry’s Law |
| Detection Range | 0.2–15% v/v |
| Repeatability | ≤5% RSD |
| Analysis Time | ≤120 s |
| Sample Volume | <1 mL |
| Power Supply | Rechargeable Li-ion Battery |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −30–85 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Weight | >3 kg |
| Dimensions | 17 × 20 × 13 cm |
| Environmental Rating | IP34, NEMA Enclosure |
| Shock & Vibration Compliance | MIL-STD-810G |
| Electrical Safety Certifications | FCC Class B, CE |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K88501 |
| Standards Compliance | ASTM D3427, IP 313, DIN 51381, NF E48-614 |
| Temperature Range | Ambient to 75 °C |
| Temperature Control | Microprocessor-based LED digital controller |
| Power Supply | 230 V, 50 Hz, 1.5 A |
| Dimensions (W×D×H) | 61 × 71 × 97 cm |
| Weight | 103 kg |
| Sample Volume | Standard 200 mL test vessel |
| Air Flow Control | Regulated compressed air supply with pressure gauge |
| Safety | Overheat protection circuit |
| Optional | Windows-based data acquisition software, heated sample sleeve, baffle kit, air bath circulator with calibrated thermometer and sinker |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | T2FM 500 |
| Sample Capacity | Full-volume oil sample deposition |
| Particle Size Range | 0–800 µm |
| Magnetic Field Gradient | High-gradient permanent magnet array |
| Solvent Consumption | Low (no compressed air required) |
| Dimensions | 46 cm × 32 cm × 45 cm |
| Weight | 10 kg |
| Compliance | ASTM D7690 |
| Optional Accessories | Heating Plate, Dual-illumination Microscope (Red Reflective / Green Transmissive), Industrial Camera, Image Acquisition Software |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K38590 |
| Sample Capacity | 10 positions |
| Temperature Range | +80 °C to –40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Refrigeration Rate | up to 5.0 °C/min |
| Refrigerant | R-507 |
| Compressor Power | 1/3 hp |
| Heating Power | 600 W |
| Power Supply | 220 V, 50/60 Hz, 7 A |
| Dimensions | 39 × 32 × 34 cm |
| Weight | 47.6 kg |
| Construction | Stainless steel housing and durable thermoplastic components |
| Compliance | ASTM D4684, D3829, D6896, D6821*, SAE J300, ILSAC GF-3/GF-4 |
| Brand | ShenKai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A1 Auto |
| Measurement Principle | CFR Engine Method (Motor Method) |
| Measurement Range | 40–120 ON/CN |
| Instrument Type | Benchtop |
| Compliance Standards | ASTM D2699, ASTM D2700, GB/T 5487–2015, GB/T 503–2016 |
| Compression Ratio Range | 4:1 to 18:1 |
| Engine Speed | 900 ± 9 rpm (Motor Method), 600 ± 6 rpm (Research Method) |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.3 mm |
| Displacement | 0.61 L |
| Cooling Jacket | Cast-iron monobloc with integrated coolant channel |
| Lubrication Pressure | 172–207 kPa |
| Cylinder Jacket Coolant Temp | 100 ± 1.5 °C |
| Intake Air Temp (Motor) | 38 ± 2.8 °C |
| Intake Air Temp (Research) | 52 ± 1 °C (at standard atmospheric pressure, auto-corrected) |
| Ignition Timing | Motor Method ε5.0 = 26 ± 1.5° BTDC (automatically adjusted per compression ratio) |
| Power Supply | AC 380 V ±10%, 50 Hz (main unit) |
| Total Power Consumption | 19 kW (12 kW + 7 kW) |
| Dimensions (W×D×H) | 1780 × 900 × 1400 mm |
| Weight | 1200 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP ON-LINE |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 2–1000 kPa |
| Temperature Range | 20–60 °C |
| Repeatability (r) | 0.30 kPa |
| Reproducibility (R) | 0.7 kPa |
| Sample Throughput Cycle Time | 7 min |
| Power Supply | 100/120/230/240 V AC, 50/60 Hz, 65 W |
| Dimensions (W × H × D) | 650 × 1160 × 400 mm |
| Weight | 50 kg |
| Explosion Protection | Class I, Division 1, Group D (NFPA 496, US) / Zone 1, II 2 G Ex d IIB T4 (EN 50016, EU) |
| Vapor-to-Liquid Ratios (V/L) | 4:1 (gasoline & crude oil), 1:2 (LPG & NPG), 20:1 (LVR temperature mode) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPSH+ Crude Oil Package |
| Application | Crude oil vapor pressure (RVP/TVPR) determination per ASTM D323, D6377, and ISO 3014 |
| Sample Handling | Mobile piston cylinder sampling system with pressurized transfer and mechanical agitation |
| Automation | Fully automated measurement cycle including purge, equilibration, pressure stabilization, and cleaning |
| Compliance | Designed to meet ASTM D6377 (TVPR), ASTM D323 (RVP), ISO 3014, and EN 13016-1 requirements |
| Operating Temperature | 37.8 °C (100 °F) controlled bath |
| Pressure Range | 0–200 kPa (0–29 psi) absolute |
| Resolution | 0.1 kPa |
| Repeatability | ≤0.5 kPa (per ASTM D6377) |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | MiniLab 153 |
| Detection Capabilities | Elemental Analysis (ICP-OES), Particle Counting & Ferrography, Viscosity, Fluid Health Assessment (Oxidation, Nitration, Sulfation, TAN, TBN, Water Content) |
| Standards Compliance | ASTM D6595, D7596, D8092, D7889 |
| Analysis Time | ≤20 minutes per sample |
| Sample Throughput | Full suite of 4 test modules in single workflow |
| Vector-Based Diagnostic Framework | Tri-Vector Analysis (Wear, Contamination, Fluid Degradation) |
| Control System | TDC (Tri-Vector Diagnostic Controller) |
| Operating Environment | Industrial field site (non-laboratory) |