BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelAurora-6
QuotationUpon Request
Cavity GradeIndustrial-Grade
Sample Capacity16–40 vessels
Microwave SourceDual Magnetron System
Max Temperature500 °C
Max Pressure15 MPa
Cavity Material316L Stainless Steel
Power Input220–240 V / 50 Hz, 16 A
Installed Power3200 W
Microwave Frequency2450 MHz
Output ModeNon-pulsed Continuous Microwave
Power Control Accuracy±1 W
Control AlgorithmHigh-Frequency Closed-Loop PID
Display7-inch HD Color Touchscreen
Cooling SystemTwin-Air Dual-Direction Forced Air Cooling with Optimized Duct Design
Operating Ambient5–40 °C, 15–80% RH
Dimensions (H×W×D)665 × 546 × 590 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelAurora-3
Price RangeUSD 21,000 – 28,000
Cavity ClassIndustrial-Grade
Max. Sample Capacity16 vessels
Microwave SourceMagnetron
Max. Temperature330 °C
Max. Pressure1500 psi
Cavity Material316L Stainless Steel (Laser-Welded, Multi-Layer PTFE-Coated)
Microwave Frequency2450 MHz
Output ModeNon-Pulsed Continuous Microwave
Cooling SystemTwin Air Dual-Direction Rapid Cooling
Safety DoorIndependent Floating Buffer Design with Auto-Interlock
Control Interface7″ High-Resolution Color Touchscreen
Temperature MonitoringDual-Sensor Infrared + Real-Time Full-Vessel Monitoring
Pressure MonitoringFull-Vessel Active Pressure Sensing
Heating ProfileSlope-Controlled Ramp, Power Calibration, Temperature Compensation
ComplianceDesigned to support ISO/IEC 17025 workflows, ASTM D5511/D5512 (waste digestion), USP <231>, EPA Methods 3050B/3051A/3052, and GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelM6
QuotationUpon Request
Cavity GradeIndustrial-Grade
Sample Capacity16–40 vessels
Microwave SourceDual Magnetron Configuration
Max Temperature500 °C
Max Pressure15 MPa
Touchscreen7″ High-Resolution Color LCD
Microwave Frequency2450 MHz
Power DeliveryNon-pulsed Continuous Microwave Output
Cavity Material316L Stainless Steel with Laser Seamless Welding & Multi-layer PTFE Coating
Cooling SystemTwin Air Bidirectional Rapid Cooling with Intelligent Airflow Control
Safety DoorIndependent Floating Buffer Safety Door with Interlocked Microwave Activation
Temperature & Pressure MonitoringDual Real-time Per-vessel Sensing
Vessel RecognitionFully Automated Position Identification Technology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelC-MAG HP 10
Heating Power1500 W
Max. Heating Temperature500 °C
Temperature UniformityCompatible with ETS-D5 Contact Electronic Thermometer
Plate Dimensions260 × 260 mm
Display TypeLED
Temperature Control Accuracy±10 K
External Temperature Sensor InterfaceETS-D5
Max. Vessel Capacity15 L
Heating Rate5 K/min
Work Surface MaterialCeramic
Housing Protection RatingIP21
Operating Ambient Temperature5–40 °C
Relative Humidity Limit80 %
Voltage230 / 120 / 100 V
Frequency50/60 Hz
Net Weight6 kg
Overall Dimensions (W × H × D)300 × 105 × 415 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelC-MAG HP 7
Heating Power1000 W
Max. Heating Temperature50–500 °C
Plate Dimensions180 × 180 mm
Operating Ambient5–40 °C, ≤80 % RH
Input Voltage230 / 120 / 100 V, 50/60 Hz
Weight5 kg
Plate MaterialSeamless Ceramic
Max. Vessel Capacity10 L
Heating Rate5 K/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelM3
Price RangeUSD 21,000 – 28,000
Cavity ClassIndustrial-Grade
Sample Capacity16 vessels
Microwave SourceMagnetron
Max Temperature330 °C
Max Pressure1500 psi
Display7″ High-Resolution Color Touchscreen
Microwave Frequency2450 MHz
Power Output ModeNon-pulsed Continuous Microwave
Cavity Material316L Stainless Steel with Laser Welding & Multi-layer PTFE Coating
Cooling SystemTwin Air Dual-Direction Rapid Cooling
Safety DoorIndependent Floating Buffer Safety Door with Interlock
Control ArchitectureFull-Vessel Temperature & Pressure Monitoring
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPreeKem
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelCash Cow
Price RangeUSD 21,000 – 28,000 (FOB)
Cavity ClassIndustrial-Grade
Sample Capacity40 vessels/batch
Microwave SourceDual Magnetron
Max Temperature400 °C
Max Pressure2200 PSI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
Country of OriginAustria
ModelMultiwave GO Plus
Cavity ClassIndustrial-grade
Sample Capacity12 samples per run
Microwave SourceIndustrial Magnetron
Max Temperature260 °C / 300 °C (depending on vessel type)
Max Pressure2200 psi
Cooling Time (12-position rotor, 180 °C → 70 °C)≤8 min (EPA-compliant)