Empowering Scientific Discovery

Shanghai Renhe Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT Instruments
OriginUSA
ModelDT-300 / DT-310
Measurement PrincipleElectroacoustic (Colloid Vibration Current, CVI)
Zeta Potential RangeUnlimited (down to ±0.1 mV)
Sample Concentration0.1–50% v/v (no dilution required)
Minimum Sample Volume2 mL
Measurable ParametersZeta potential, dynamic electrophoretic mobility, Debye length, particle size distribution (via optional ultrasound attenuation spectroscopy), rheological properties (viscoelastic moduli), solid content, porosity
Software PlatformMicrosoft Access-based database with audit trail capability
Optional ModuleAutomated titration system (DT-310 only)
Compliance ContextDesigned for GLP/GMP-aligned laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFRITSCH
OriginGermany
ModelAnalysette 3
ComplianceISO 3310, ASTM E11, DIN 66165, EN 10204 3.1B
Measurement Range (Dry)32 µm – 63 mm
Measurement Range (Wet)20 µm – 10 mm
Measurement Range (Micro-fine)5 µm – 100 µm
Max Sieve Stack (50 mm)10 trays
Max Sieve Stack (25 mm)16 trays
Sample Capacity (Dry, <100 µm)>100 kg
Sample Capacity (Dry, <25 mm)>1 kg
Sample Capacity (Wet)20–100 g
Sample Capacity (Micro-fine)0.2–0.5 g
Sieving Duration (Dry)3–20 min
Sieving Duration (Wet)3–10 min
Sieving Duration (Micro-fine)30–60 min
Amplitude DisplayDigital (mm)
Frequency DisplayDigital (Hz)
Control InterfaceRS232
SoftwareAUTOSIEVE™
IP RatingIP65
Tension ControlElectronic torque-controlled sieve clamping system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFRITSCH
OriginGermany
ModelAnalysette 18
Measurement PrincipleDry Mechanical Vibratory Sieving
Max. Sample Capacity15 kg (standard), up to 25 kg with optional large-diameter sieve stack
Sieve Aperture Range20 µm – 125 mm
Max. Sieve Diameter450 mm (18")
Sieving Time5–60 min
Drive SystemDual Asymmetric Counter-Rotating Motors
ComplianceISO 2591-1, ISO 9276-1, ASTM E11, USP <786>
SoftwareAUTOSIEVE v5.x (FDA 21 CFR Part 11 compliant audit trail & user access control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT (USA)
OriginUSA
ModelDT-600
Measurement PrincipleUltrasonic Spectroscopy (1–100 MHz)
Sample Concentration Range0.1–50 vol% (no dilution required)
Viscosity Range0.5–100 cP (±3% accuracy)
Longitudinal Modulus (G*) Measurement1–100 MHz
Solvent CompatibilityAqueous, polar, and non-polar media
Zeta Potential & Particle SizeDirect measurement in concentrated dispersions
Isoelectric Point (IEP) DeterminationModel-independent, no Debye-Hückel or Smoluchowski approximation required
Titration FunctionIntegrated automated potentiometric titration module
Data ManagementMicrosoft Access-based local database with audit-ready export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT Instruments
OriginUSA
ModelDT-330
Measurement PrincipleElectroacoustics (Colloid Vibration Current, CVI) & Electrophoretic Acoustics (ESA)
Sample Concentration Range0.1–50 vol% (no dilution required)
Minimum Sample Volume2 mL
Zeta Potential RangeNo theoretical lower limit
Compatible SolventsAqueous, polar, and non-polar media
Porosity MeasurementYes (via high-frequency conductivity probe)
Surface Zeta Potential on Porous SolidsYes
Output ParametersDynamic electrophoretic mobility, Debye length, surface charge density, solid content, rheological properties
Compliance ContextDesigned for GLP/GMP-aligned labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT (USA)
OriginUSA
ModelDT-700
Measurement Range0–200 µS/m
Resolution1 µS/m
Accuracy±2% of reading
Probe Operating Temperature−20 °C to +200 °C
DisplayLCD
InterfaceUSB for external storage export
Form FactorPortable handheld unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOcchio
OriginBelgium
ModelSIEVECAL
ApplicationAutomated optical calibration and metrological analysis of test sieves per ASTM E11, ISO 3310-1, and DIN EN ISO 3310-1
Imaging Resolution1.2 µm (pixel-limited)
Sieve Diameter Support200–300 mm (8–12 inch)
Aperture Size Range20 µm – 12.5 mm
Measurement ParametersFeret X/Y diameters, maximum inscribed circle diameter, wire thickness (X/Y), aperture area, blockage ratio, statistical distribution (mean, min, max, σ)
Compliance StandardsASTM E11-13, ISO 3310-1:2016, DIN EN ISO 3310-1
Analysis Time≤120 s per sieve
Optical SystemCollimated 450 nm blue LED backlight + telecentric zoom lens + USB3 monochrome camera (1.3 MP)
Automation LevelFully motorized XY translation + 360° continuous rotation stage
SoftwareOcchio SIEVECAL Suite with audit-trail-capable reporting, GLP-compliant data storage, and CFR 21 Part 11–ready configuration options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT Instruments
OriginUSA
ModelDT-100 / DT-110
Measurement PrincipleUltrasonic Attenuation Spectroscopy (UAS)
Particle Size Range5 nm – 1000 µm
Sample Concentration Range0.1–50% v/v (undiluted)
Operating Frequency Range1–100 MHz
Minimum Sample Volume (DT-110)< 5 mL
Dispersion Media CompatibilityAqueous, polar, and non-polar liquids
Data ManagementMicrosoft Access-based database
Calibration-Free OperationYes
Adjustable Transducer GapYes
Compliance ContextSupports GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT (USA)
OriginUSA
ModelRUFUTO-871
Measurement Range1–20 and 1–200 (dimensionless)
Accuracy±2%
CalibrationWith deionized water or reference liquids of known permittivity
Probe TypeOpen-ended coaxial probe
Sample CompatibilityAqueous solutions, polar and non-polar organic solvents, solvent mixtures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDT (USA)
OriginUSA
ModelDT-1202
Particle Size Range5 nm – 1000 µm
Zeta Potential Measurement RangeUnlimited (±0.1 mV accuracy)
Concentration Range0.1–50 vol%
pH Range0.5–13.5
Conductivity Range0.0001–10 S/m
Temperature Range<50 °C
Max. Viscosity20,000 cP
Frequency Range1–100 MHz
Minimum Sample Volume2 mL
Titration Resolution0.1 µL
Simultaneous MeasurementParticle Size + Zeta Potential in One Cell
Optional ModulesRheology, pH, Conductivity, Temperature, Auto-Titration, Non-Aqueous Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelPFT
Instrument TypePowder Flow Tester
Measurable ParametersCohesive Strength, Internal Friction Angle, Wall Friction Angle
Vertical Load Range7 kg (±0.6% FSR)
Axial Speed0.1 mm/s (adjustable up to 1 mm/s)
Displacement Accuracy±0.3 mm
Torque Range±7.0 N·m (±1.2% FSR)
Hopper Rotation Speed1–5 rpm
Temperature Sensing–20°C to 120°C
Humidity Sensing10–95% RH (±5% accuracy)
Dimensions (W×D×H)36.2 × 39.7 × 67.6 cm
Weight34 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLUM
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLUMiSizer
Price RangeUSD 68,000 – 95,000
Sample Capacity12 positions
Measurement PrincipleSpatially Resolved Extinction Profile Analysis (STEP Technology)
Temperature Control Range4 °C to 60 °C (±1 K)
Sample Volume per Cell0.05 mL to 2.0 mL
Concentration Range0.00015 wt% to 90 wt%
Viscosity Range0.8 mPa·s to 10⁸ mPa·s
Particle Size Range (Stability Mode)10 nm to 1000 μm
Particle Size Range (ISO 13318-2 Compliant Mode)20 nm to 100 μm
Density Rangeup to 22 g/cm³
Acceleration Range6×g to 2300×g
Optical WavelengthsMulti-wavelength source (e.g., 870 nm, optionally 470 nm and/or 650 nm)
ComplianceISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready
Dimensions (W×H×D)37 cm × 27 cm × 60 cm
Weight40 kg
Power Supply100–240 V AC, 50/60 Hz