- All
- Favorite
- Popular
- Most rated
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | SCAN Series |
| Particle Size Range | 10 µm – 50 mm (extendable to 2 µm – 20 cm) |
| Optical Resolution | Up to 600 Mpx (Scan 700) |
| Illumination | Broadband white light (350–640 nm), transmission + reflection modes |
| Imaging Sensor | High-speed CCD linear array |
| Software | Callisto 2D/3D |
| Dispersion | Dry-mode linear disperser with anti-adhesion metal coating |
| Sample Stage | 242 × 320 mm (Scan 700) |
| Compliance | ASTM D7927, ISO 9276-6, USP <1788>, GLP-ready audit trail in Callisto |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFrac |
| Quotation | Upon Request |
| Principle | Centrifugal Fracture Testing (Dynamic Load Application via Rotating Rotor) |
| Max. Centrifugal Force Range | 0.1 N – 6.5 kN |
| Rotational Speed Range | 100 – 13,000 rpm |
| Tensile Strength Measurement Range | up to 80 MPa |
| Sample Capacity | 8 parallel specimens |
| Sample Dimensions | max. 30 × 30 × >1 mm³ |
| Bonded Area Diameter | 7 mm, 10 mm or custom |
| Bonded Surface Materials | metallic & non-metallic substrates |
| Specimen Mass Range | 4.1 g – 38.7 g (Cu/W-based reference: ~58 g) |
| Temperature Control Range | −11 °C to +40 °C |
| Measurement Duration | 1 min – 99 h |
| Compliance | ISO 4624, DIN EN 15870, DIN EN 14869-2, JIS K 5600-5-7 |
| Data Interface | USB |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Max. Power Consumption | 1050 W |
| Net Weight | 56 kg |
| Dimensions (W×H×D) | 380 × 296 × 640 mm³ |
| Software Platform | SEPView® v6.x with real-time critical force calculation, statistical comparison, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | SHASHIN KAGAKU |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SQ-9000 |
| Pricing | Upon Request |
| Effective Measurement Range (X×Y×Z) | 700 × 900 × 60 mm |
| Maximum Workpiece Dimensions (X×Y×Z) | 1000 × 1250 × 60 mm |
| Maximum Workpiece Thickness | 60 mm |
| Minimum Readout Unit | 0.1 µm |
| XY Measurement Accuracy | U₁ = (3 + L/250) µm, U₂ = (4 + L/230) µm |
| Z-Axis Measurement Accuracy | (1.5 + 4L/1000) µm |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LUMiReader PSA |
| Pricing | Upon Request |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | Zephyr LDA / Zephyr ESR / Morpho 3 |
| Dry Measurement Range (Zephyr LDA) | 7 µm – 5000 µm |
| Wet Measurement Range (Zephyr LDA) | 1 µm – 3000 µm |
| Dry Measurement Range (Zephyr ESR) | 30 µm – 30 mm (extendable lower limit) |
| Dry Measurement Range (Morpho 3) | 500 µm – 10,000 µm |
| Analysis Time | 1–3 min per sample |
| Camera System | 5 MP CCD (Zephyr LDA/ESR), dual 1.3 MP (Morpho 3: 24-bit color front + 8-bit monochrome side) |
| Light Source | 440 nm blue LED (Zephyr LDA/ESR), dual diffuse white LED + monochromatic LED (Morpho 3) |
| Lens Type | Telecentric (Zephyr LDA), dual telecentric (Zephyr ESR), fixed-focus (Morpho 3) |
| Dispersion | Vibratory feed + transverse vacuum (Zephyr LDA), gravity-assisted vibration (Zephyr ESR), controlled rotary vibration + linear belt transport (Morpho 3) |
| Auto-Cleaning | Compressed air + vacuum (all models) |
| Software | Callisto 3D |
| Compliance | ISO 13322-2, ASTM E2927, FDA 21 CFR Part 11 (with optional 3Q validation: IQ/OQ/PQ) |
| Dimensions & Weight | Zephyr LDA: 85 × 47 × 64 cm, 52 kg |
| Zephyr ESR | 80 × 44 × 60 cm, 43 kg |
| Morpho 3 | 99 × 52 × 60 cm, 75 kg |
| Brand | RHEOTECH |
|---|---|
| Origin | Japan |
| Model | FUDOH RTC-3002D |
| Load Capacity | ±200 N |
| Stroke Range | 0.1–99.9 mm (0.1 mm resolution) |
| Test Speed Options | 2, 5, 6, 10, 20, 30 cm/min or 5, 6, 10, 20, 30, 60 cm/min |
| Display | Triple 3-digit LED (force, displacement, time) |
| Auto-zero Function | Yes |
| Power Supply | 220–250 V AC, 50/60 Hz |
| Dimensions | 260 W × 430 H × 280 D mm |
| Weight | 15 kg |
| Compliance | Designed for ISO 11357, ASTM F3165, USP <1043>, and GLP-compliant texture analysis workflows |
| Brand | Shashin Kagaku |
|---|---|
| Origin | Japan |
| Model | PV Cell Grid Line 3D Profilometer |
| Measurement Principle | White-Light Interferometry |
| Light Source Options | White LED (430–700 nm, >50,000 h), Tungsten-Halogen (400–900 nm, 10,000 h), Deuterium-Halogen (220–900 nm, 1,000 h) |
| Objective Lenses | 1× (FOV 6.6 × 8.8 mm, Optical Resolution 11 µm, Working Distance 15 mm), 5× (FOV 1.32 × 1.76 mm, Optical Resolution 2.3 µm, Working Distance 4 mm), 50× (FOV 0.132 × 0.176 mm, Optical Resolution 0.51 µm, Working Distance 3 mm) |
| Measurement Capabilities | Simultaneous 3D topography, line width (LW), line height (LH), sidewall angle, step height, roughness (Sa, Sq), and edge definition for metallized grid lines on silicon solar cells |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFuge |
| Price | Upon Request |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | FC200 Series |
| Particle Size Range | 0.2 µm – 3 mm |
| Imaging Resolution | Down to 0.17 µm/pixel |
| Number of Morphological Parameters | 50–80 |
| Sample Volume Range | Microliter to >1 L |
| Maximum Undiluted Sample Concentration | 5% (v/v) |
| Light Source | 440–450 nm Collimated Blue LED |
| Camera Options | 5–12 MP CMOS/CCD |
| Software Platform | Callisto 2D/3D |
| Regulatory Compliance | 21 CFR Part 11, IQ/OQ/PQ (3Q) Validation Support |
| Pump Types | Peristaltic, Diaphragm, Syringe, or Integrated Injection Pumps |
| Temperature Control (FC200TC) | Ambient to 140 °C |
| Specialized Configurations | FC200M+(HR), FC200S+(HR), FC200TC, FC200P, FC200BAG, IPAC 1, IPAC 2 CMP |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500o / 500o HR / 500o XY |
| Measurement Principle | Digital Image Analysis (Static Imaging) |
| Dry Dispersion | Integrated Vacuum-Based System |
| Wet Dispersion | Computer-Controlled Syringe Pump with Three-Way Valve |
| Optical Configuration | Collimated 440 nm Blue LED Backlight (Transmitted) + Diffuse White LED (Reflected) |
| Camera | Progressive Scan CMOS (6.6 MP for 500o |
| Lens | Zoom Telecentric Objective |
| Pixel Resolution Range | 0.19–4.7 µm/pixel (model-dependent) |
| Field of View | Up to 10.27 × 14.00 mm (low-mag) down to 730 × 522 µm (high-mag) |
| Dry Mode Range | 0.2–3000 µm |
| Wet Mode Range | 0.8–300 µm |
| Reflectance Mode Range | 1–3000 µm |
| Analysis Time | 1–3 min per sample |
| Software | Callisto 2D (500o, 500o HR) or Callisto 3D (500o XY) |
| Compliance | ISO 13322-1 & ISO 13322-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready 3Q Validation (IQ/OQ/PQ) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (DMA 4100M) / 0.00005 g/cm³ (DMA 4500M) / 0.000005 g/cm³ (DMA 5000M) |
| Temperature Range | 0 °C to 95 °C |
| Temperature Accuracy | ±0.05 °C (4100M) / ±0.03 °C (4500M) / ±0.01 °C (5000M) |
| Minimum Sample Volume | 1 mL |
| Repeatability (Std. Dev.) | 0.00005 g/cm³ (4100M) / 0.00001 g/cm³ (4500M) / 0.000001 g/cm³ (5000M) |
| Display | 10.4" PCAP TFT Touchscreen (640 × 480 px) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO 12084, ASTM D4052, USP <841> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid (including high-viscosity, solid-at-room-temperature, and pressurized samples) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00005 g/cm³ (standard deviation) |
| Temperature Range | −10 °C to +200 °C (14 °F to 392 °F) |
| Temperature Accuracy | ±0.03 °C |
| Pressure Range | 0–500 bar (0–7,250 psi) |
| Minimum Sample Volume | 2 mL |
| Measuring Cell Material | Hastelloy C-276 |
| Cell Volume | ~2 mL |
| Dimensions | 510 × 330 × 230 mm (20 × 13 × 8.7 in) |
| Weight | 27.1 kg (59.7 lb) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4 × USB 2.0, 2 × S-Bus, 1 × Ethernet (100 Mbit), 1 × CAN Bus, 1 × RS-232, 1 × VGA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (OUM) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Temperature Range (Sample) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Sample Volume | 1–2 mL |
| Resolution | 0.0001 g/cm³ (density), 0.1 °C (temperature) |
| Environmental Operating Range | −10 to +50 °C (standard) |
| Protection Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA35 Ex & DMA35 Ex Petrol) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Interface | Bluetooth®, RFID, IrDA |
| Power Supply | 3 × AA alkaline batteries (LR06) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiReader X-Ray |
| Pricing | Upon Request |
Show next