Add to compare
BrandGrabner
OriginAustria
ModelMINITEST FFK
Test PrincipleCorrosion-Resistant Capillary Extrusion (DIN 51805)
Temperature Range−50 °C to +30 °C
Temp. Accuracy±0.1 °C
Pressure Range0–300 kPa
Pressure Accuracy±0.1 kPa
Dimensions196 × 315 × 175 mm
Weight10 kg
Power Supply100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFieldLab 58
Product TypePortable Instrument
Detection CapabilitiesElemental Analysis (XRF), Particle Counting, Kinematic Viscosity at 40 °C, FTIR-based Oxidation, Nitration, Soot, Water, TAN/TBN, Fuel & Glycol Contamination
Power SupplyRechargeable Lithium-ion Battery
Dimensions487.68 × 386.08 × 228.6 mm (L × W × H)
ComplianceASTM D6595, D7690, D7883, D7621, D7943, ISO 11171, ISO 4406, ISO 21468, ISO 21469, USP <1058>, FDA 21 CFR Part 11 (audit trail enabled in software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelLaserNet 200 Series
TypePortable Instrument
Detection ParametersParticle Counting, Ferrous Particle Concentration & Count (>25 µm), Morphological Wear Debris Classification, Free Water (ppm), Bubble/Contaminant Discrimination
Standards ComplianceASTM D7596, ISO 4406, NAS1638, SAE AS4059, ASTM D6786, ISO 11171
Imaging TechnologyDirect High-Resolution CCD Imaging with Laser Illumination
Particle Size Range≥2 µm (morphology-resolved), ≥20 µm (automated classification), ≥25 µm (ferrous count)
Max Sample Contamination Tolerance5,000,000 particles/mL
Max Soot Tolerance2% w/w
Auto-Gain Control (AGC)Yes
Onboard Data ManagementAsset Tracking, Trend Analysis, Custom Cleanliness Thresholds
Dimensions35.6 cm H × 36.8 cm W × 78.7 cm D
Weight8.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelNOACK
Standard ComplianceASTM D5800, DIN 51581
Temperature Range150–350 °C (±0.1 °C accuracy)
Heating Medium OptionsAluminum block (non-Wood’s alloy) or Wood’s alloy bath
Power Supply230 V, 50 Hz, 5.8 A
Dimensions (K44090)59 × 35 × 68 cm
Weight (K44090)26.7 kg
Dimensions (K44091)54 × 38 × 37 cm
Weight (K44091 with accessories)38.2 kg
Sample Mass65 g
Test Duration60 min at specified temperature
Air Flow ControlManual (incl. inclined-tube manometer, 0–30 mm H₂O) or optional automated pressure regulation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK39495
Temperature Range25–84 °C
Temp. Stability±0.05 °C
Stirring Speed0–2000 rpm
Stirring Accuracy±1 rpm
Simultaneous Test Capacity7 × 100 mL samples
Bath MediumWater or white mineral oil
Bath Volume15.15 L
Power Supply220–240 V / 50 Hz / 12 A
Dimensions (W×D×H)52.7 × 38.75 × 74.9 cm
Heating Power75 W (1/10 hp)
Bath MaterialTransparent polycarbonate (25.5 × 28 × 24 cm)
Standards ComplianceASTM D1401, D6074, D6158
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelFK35100
Sample Capacity6
Temperature Range51.7–399 °C
Temperature Stability±0.5 °C (±1 °F)
Maximum Air Flow Rate10 L/h
Power Supply220–240 V, 50/60 Hz, Single-Phase, 15.9 A
Dimensions83 × 37 × 105 cm
Weight122.9 kg
ComplianceASTM D4636, D5968, D6594
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK26210-3
Standard ComplianceASTM D6082
Test Temperature150 °C
Temperature Uniformity±0.5 °C
Bath Volume38.5 L
Air Flow Rate200 mL/min
Power Supply220–240 V, 50 Hz
Dimensions (W×D×H)82 × 38 × 79.4 cm
Weight28.1 kg
Heating SystemImmersed copper heater with PID-controlled microprocessor
Temperature DisplayDual LED, selectable ℃/°F
ConstructionSteel base with chemical-resistant polyimide enamel coating
IncludesTwo 1000 mL calibrated test cylinders, two calibrated antifoam heads, two air inlet tubes, two exhaust tubes, two rubber stoppers, one bath tank, one support stand
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK18200 Series Oxidation Stability Tester
Standards ComplianceASTM D2112, D2272, D4742
Operating Pressure90 psi (620 kPa) initial, up to 500 psi (3450 kPa) burst rating
Temperature RangeAmbient to 200 °C
Control Stability±0.02 °C
Rotation Speed100 rpm ± 1 rpm
Bath Capacity68 L (2-cell), 95 L (3-cell), 121 L (4-cell)
Heating Power0–2750 W (2/3-cell), 0–3750 W (4-cell)
Drive Motor0.5 hp continuous-duty, spherical bearing, integrated gear reduction
Bearing TypePTFE-coated carbon fluoropolymer
Pressure SensingDirect-mount transducer on oxygen bomb
SafetyAuto-shutdown at >177 °C or >16.7 °C above setpoint
SoftwareOxidata™ v5.x (Windows-based, FDA 21 CFR Part 11–ready audit trail, GLP-compliant data archiving)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK50119
Test Plate Temperature RangeUp to 400 °C
Sample Oil Temperature RangeUp to 210 °C
Spray Speed0–1800 rpm (digital display)
Timer Range0–99.9 hours (adjustable countdown)
Acid Gas Flow Rate0.2–1.0 L/h
Oil Capacity0.35 L
Power Supply220–240 V, 50/60 Hz, 5 A
Test System Dimensions81 × 46 × 53 cm, 22.7 kg
Control Unit Dimensions46 × 30 × 46 cm, 11.3 kg
Temperature Display Units°C or °F selectable
ComplianceFTM 791-3462
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelFK12190
Sample Capacity6 positions
Test Temperature RangeAmbient to 127 °C
Bath Medium9.5 L white mineral oil
Temperature Control Accuracy±0.5 °C at 110 °C
Air Flow Rate1.0 ±0.1 L/h (independent flowmeter & control valve)
Stirring Motor1/20 hp recirculating agitator
ComplianceASTM D2440, D4636, D5968, D6594
DisplayDual-scale digital LED (°C/°F), real-time and setpoint
SafetyOver-temperature cut-off with automatic power disconnection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK18650
Standard ComplianceASTM D5074, STP512A L-60-1 (formerly CRC L-60), FTM 791-2504
Test Temperature162.8 ± 0.6 °C
Air Flow Rate1.1 L/h
Drive Speed1725 rpm
Load128 W
Power Supply220–240 V, 50 Hz, single-phase, 15 A
Dimensions (Test Chamber)61 × 61 × 37 cm
Dimensions (Control Cabinet)60 × 60 × 44 cm
Weight149.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFDM 6000 Series
Product TypePortable Instrument
Detection ParameterFuel Dilution in Engine Oil
Detection PrincipleSurface Acoustic Wave (SAW) Sensor + Headspace Vapor Analysis per Henry’s Law
Detection Range0.2–15% v/v
Repeatability≤5% RSD
Analysis Time≤120 s
Sample Volume<1 mL
Power SupplyRechargeable Li-ion Battery
Operating Temperature10–40 °C
Storage Temperature−30–85 °C
Relative Humidity10–90% RH (non-condensing)
Weight>3 kg
Dimensions17 × 20 × 13 cm
Environmental RatingIP34, NEMA Enclosure
Shock & Vibration ComplianceMIL-STD-810G
Electrical Safety CertificationsFCC Class B, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK88501
Standards ComplianceASTM D3427, IP 313, DIN 51381, NF E48-614
Temperature RangeAmbient to 75 °C
Temperature ControlMicroprocessor-based LED digital controller
Power Supply230 V, 50 Hz, 1.5 A
Dimensions (W×D×H)61 × 71 × 97 cm
Weight103 kg
Sample VolumeStandard 200 mL test vessel
Air Flow ControlRegulated compressed air supply with pressure gauge
SafetyOverheat protection circuit
OptionalWindows-based data acquisition software, heated sample sleeve, baffle kit, air bath circulator with calibrated thermometer and sinker
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK38590
Sample Capacity10 positions
Temperature Range+80 °C to –40 °C
Temperature Control Accuracy±0.1 °C
Refrigeration Rateup to 5.0 °C/min
RefrigerantR-507
Compressor Power1/3 hp
Heating Power600 W
Power Supply220 V, 50/60 Hz, 7 A
Dimensions39 × 32 × 34 cm
Weight47.6 kg
ConstructionStainless steel housing and durable thermoplastic components
ComplianceASTM D4684, D3829, D6896, D6821*, SAE J300, ILSAC GF-3/GF-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMiniLab 153
Detection CapabilitiesElemental Analysis (ICP-OES), Particle Counting & Ferrography, Viscosity, Fluid Health Assessment (Oxidation, Nitration, Sulfation, TAN, TBN, Water Content)
Standards ComplianceASTM D6595, D7596, D8092, D7889
Analysis Time≤20 minutes per sample
Sample ThroughputFull suite of 4 test modules in single workflow
Vector-Based Diagnostic FrameworkTri-Vector Analysis (Wear, Contamination, Fluid Degradation)
Control SystemTDC (Tri-Vector Diagnostic Controller)
Operating EnvironmentIndustrial field site (non-laboratory)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
Model SeriesK12290, K12219, K12339, K12395
Sample Capacity8 / 12 / 30 / 60 positions
Temperature RangeAmbient to 100 °C
Temperature Stability±0.1 °C (±0.2 °F)
Bath Volume37.8 L (8-pos) / 71.9 L (12-pos) / 227 L (30-pos) / 432 L (60-pos)
Bath MediumWhite Mineral Oil
ComplianceASTM D943, D2274, D2893, D4310, D6158
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelFluidScan 1000
Product TypePortable Instrument
Detection PrincipleDirect Reading Infrared (DIR) Spectroscopy
ComplianceASTM D7889, ASTM E2412, ASTM D4739, ASTM D664, ASTM E1655
Key ParametersTAN (mg KOH/g), TBN (mg KOH/g), Oxidation (Abs/0.1 mm), Nitration (Abs/mm²), Sulfation (Abs/mm²), Water (ppm), Glycol (%), Soot (%), FAME (%), Residual Carbon, Additive Depletion, Fuel Dilution, Oil Mismatch Index, FFA (%), Total Glycerin, Antioxidant Content (%)
Sample Volume1–2 drops
Measurement Time~60 seconds
PowerRechargeable Li-ion battery (≥6 h operation)
Dimensions240 × 140 × 70 mm
Weight1.4 kg
SoftwareFluidScan Manager (PC-based, with trend analysis, asset management, automated reporting, audit trail, and data synchronization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLISICO
OriginShanghai, China
ModelLS-O (Rotating Bomb Oxidation Method)
Detection ParameterOxidation Stability
Temperature Control Points140.0 ± 0.1 °C and 150.0 ± 0.1 °C
Rotation Speed100 ± 5 rpm
Pressure Range0–1.6 MPa (Pressure Sensor Accuracy: ±0.1% FS
Precision Gauge0.25 Class)
Power Consumption≤1400 W
Dimensions300 × 500 × 500 mm (W × D × H)
Weight40 kg
Compliance StandardsSH/T 0193, ASTM D2272
InterfaceEthernet for LIMS integration
Data StorageLocal HDD with persistent multi-test archive
Max Concurrent Units per PC4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelFK39199
Temperature RangeUp to 100 °C
Bath Capacity38.5 L (water)
Power Supply220–240 V, 50/60 Hz
Dimensions52.7 × 38.75 × 74.9 cm
ConstructionStainless steel wetted parts
Standards ComplianceASTM D2711, DIN 51353, ASTM D1401 (via configuration)
Control SystemMicroprocessor-based LED digital temperature controller with dual independent stirrer speed control and digital RPM display
IlluminationIntegrated LED lighting with transparent front viewport
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK56190 (1 L/h per sample) / K56290 (15 L/h per sample)
Sample Capacity12 positions
Temperature Range80–200 °C
Control Stability±0.2 °C
Heating MediumAluminum Block
Standards ComplianceIP 48, IP 280, IP 306, IP 307, IP 331, IP 335
DisplayDual-line LED, ℃/°F selectable
Overheat ProtectionAutomatic power cutoff above setpoint
Air Flow ControlIndependent precision mass flow regulation per station
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK30165NACE
Sample Capacity6 positions
Bath Volume41.6 L
Temperature RangeAmbient to 104°C (220°F)
Temperature Stability±0.5°C (±1°F)
Stirring Speed1000 rpm
Heating MediumWhite mineral oil
Power Supply220–240 V, 50 Hz, 6.8 A, Single-phase
Dimensions (W×D×H)83 × 36 × 69 cm
Weight35.8 kg
ConstructionStainless steel housing with chemical-resistant polyurethane coating
Motor TypeExplosion-proof ball-bearing induction motor, 1/12 hp
Control SystemMicroprocessor-based with °C/°F toggle and digital setpoint display
Overtemperature ProtectionIntegrated safety circuit
ComplianceASTM D665, D6158, D3603, IP 135, ISO 7120, DIN 51585, FTM 791-4011, NFT 60-151
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK12239
Temperature RangeAmbient to 200 °C
Temperature Stability±0.1 °C (±0.2 °F)
Bath MediumSilicone Oil
Sample CapacityUp to 12 glass vessels (10 for ASTM D5968 / FTM 791-5307/5308)
Air Flow ControlOptional analog flowmeter or digital mass flow controller
Temperature DisplayDual-line LED, °C/°F selectable
Power Supply220–240 V, 50/60 Hz
Dimensions (W×D×H)65 × 61 × 107 cm
Weight96.6 kg
ComplianceASTM D943, D2274, D2440, D2893, D4310, D4636, D5968, D6594
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectro Scientific
OriginUSA
ModelMiniVisc 3000 Series (10–350 cSt @ 40 °C) / MiniVisc 3050 Series (1–700 cSt @ 40 °C)
Measurement PrincipleGravity-driven capillary flow in split-cell microchannel
Temperature Control40 °C ± 0.1 °C (PID-regulated)
Sample Volume60 µL
PowerRechargeable Li-ion battery (≥6 h runtime)
DisplayIntegrated high-resolution touchscreen
Weight1.8 kg
Dimensions152 × 127 × 203 mm (H × W × L)
ComplianceASTM D445, ISO 3104, IP 71
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelKLA-1-TS / KLA-2-TS / KLA-3-TS
Temperature Range+80 °C to –80 °C
Resolution0.06 °C
Accuracy±0.1 °C
RepeatabilityCompliant with or better than ASTM D2500, D97, D5771–D5773, D5853, D5950
Cooling SystemDual-stage thermoelectric (Stage 1: –40 °C
Stage 2–80 °C)
Display6.4″ TFT/LCD touchscreen (640 × 480, 262K color)
Data Storage>60,000 test records in Microsoft Excel-compatible format
ComplianceASTM, ISO, DIN, IP standards per model configuration
Sample Detection MethodCoaxial fiber-optic pulse photometry (cloud point)
Max. Test Heads6
Power Supply220 V ±15%, 50–60 Hz
Dimensions66 × 60 × 80 cm
Weight80 kg