| Brand | LISICO |
|---|---|
| Model | LS-100 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Configuration | Modular Benchtop System |
| Optical Architecture | Michelson Interferometer with Solid-State Laser Reference |
| Spectral Range | 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | Adjustable down to 4 cm⁻¹ |
| Detector | Thermoelectrically Cooled InGaAs |
| Sampling Modes | Transmission (liquids), Diffuse Reflectance (solids), Non-contact Reflectance (Dual-Eye probe) |
| Connectivity | USB 3.0, Ethernet, Optional Fiber-Optic Interface (up to 8 channels) |
| Software Platform | S-Cal (PLS/QPLS modeling), S-Seq (automated sequence control), S-Online (real-time DCS integration) |
| Brand | LISICO |
|---|---|
| Model | Online FTIR Spectrometer |
| Type | Fourier Transform Infrared (FTIR), Online Process Analyser |
| Wavenumber Range | 8000–350 cm⁻¹ (extendable to 12,500–4000 cm⁻¹) |
| Spectral Resolution | < 0.25 cm⁻¹ |
| Wavenumber Accuracy | ≤ 0.01 cm⁻¹ |
| Interferometer | Domestic high-stability立体角镜 interferometer (permanent alignment, >10-year service life) |
| Beam Splitter | Standard KBr-coated mid-IR beam splitter (moisture-resistant option available) |
| Detector | Standard room-temperature DLaTGS |
| IR Source | Long-life ceramic source (1550 K) |
| Probe Material | Hastelloy C-22 |
| Probe Dimensions | Ø12 mm × 300 mm |
| Fiber Type | PIR-900/1000 silver halide fiber |
| Operating Temperature | −100 °C to +140 °C (custom ranges available) |
| Pressure Rating | Up to 200 bar |
| Interface | SMA connector |
| Fiber Length | 1.5 m |
| Minimum Bend Radius | 130 mm |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 650 / GDA 150 |
| Pricing | Available Upon Request |
| Brand | SPECTRUMA |
|---|---|
| Country of Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Optical Resolution | <20 pm (FWHM) |
| Spectral Range | 190–800 nm (PMT), 200–800 nm (CCD option) |
| Maximum Analysis Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Detection Limits | Sub-ppm |
| Excitation Source | DC (0–1500 V, 0–250 mA), RF (up to 150 W, pulsed mode optional for GDA 750) |
| Sample Diameter Range | 1–8 mm |
| Vacuum System | Dual-stage rotary vane pump (oil-free for source), optional turbomolecular pump |
| Software Platform | WinGDOES (Windows XP or later) |
| Weight | ~580 kg |
| Dimensions | 1380 × 1440 × 890 mm |
| Brand | LISICO |
|---|---|
| Model | LS-100-Pro |
| Type | Online FT-NIR Spectrometer |
| Channels | 8-channel multiplexed |
| Form Factor | Integrated cabinet system with embedded industrial PC, temperature control module, and PLC for DCS integration |
| Dimensions | 540 mm × 350 mm × 650 mm (L×W×H) |
| Weight | 10 kg (excluding spectrometer optics core) |
| Origin | Shanghai, China |
| Instrument Category | Domestic manufactured |
| Distribution Model | Authorized distributor supply |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Beam Configuration | Single-beam |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 290 nm – 1650 nm |
| Wavelength Accuracy | > ±20 nm |
| Stray Light | < 0.01% T |
| Automation Level | Automatic Wavelength Scanning |
| Sample Interface | Non-contact, optical surface |
| Measurement Time | ~20 s per analysis |
| Calibration | User-definable or factory-customized for specific product matrices |
| Product Parameter Output | Up to 4 simultaneous quantitative parameters per measurement |
| Preloaded Methods | Up to 8 product-specific analysis profiles |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 175–770 nm |
| RF Generator | 27 MHz Solid-State |
| Optical Purge Flow | ≥0.5 L/min (Argon or Nitrogen) |
| Sample Throughput | Up to 700 samples/day |
| Detector | High-Quantum-Efficiency CCD Array |
| Compliance | ASTM D5185, D6595, ISO 11885, USP <233>, EPA Methods 200.7, 6010D, 6020B, GLP/GMP-ready with 21 CFR Part 11–compliant software options |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppb to ppm |
| Repeatability | ≤1% RSD |
| Long-Term Stability | ≤0.1% RSD |
| Wavelength Range | 130–770 nm |
| Optical Resolution | ≤0.008 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTRO TEST |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Spectral Coverage | Full-Spectrum (Echelle + Prism Cross-Dispersion) |
| Price Range | USD 52,000–65,000 (FOB Hamburg) |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA Alpha |
| Pricing | Upon Request |