- All
- Favorite
- Popular
- Most rated
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | KU-2 |
| Instrument Type | Rotational Viscometer |
| Measurement Range | 40–141 KU (Krebs Units), 32–1099 g, 27–5274 cP |
| Compliance | ASTM D562, ISO 2555, GB/T 9269 |
| Output | Analog voltage (0–5 V DC) for optional printer or data logger |
| Sample Volume | ~500 mL |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions | 22.9 × 15.2 × 30.5 cm |
| Weight | 6.8 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Viscometer |
| Model | DV-II+Pro EXTRA |
| Bearing System | Precision Ball-Bearing Suspension (excludes LV models) |
| Speed Range | 0.1–200 rpm (54 programmable speeds) |
| Viscosity Accuracy | ±1.0% of reading |
| Repeatability | ±0.2% |
| Displayed Parameters | Viscosity (cP or mPa·s), Temperature (°C or °F), Shear Rate/Shear Stress, % Torque, Rotational Speed, Rotor ID, Timed Stop Countdown |
| Included Accessories | EZ-Lock Quick-Connect Rotor System, Q-Drive Vertical Positioning Stand, Integrated Temperature Probe, RheoCalc Software, DV Loader Software, Standard Rotor Set (4 for LV |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | LVT/RVT |
| Type | Analog Dial Viscometer |
| Standard Spindles | LVT includes LV#1–LV#4 |
| Motor | Multi-speed, low-noise synchronous motor |
| Compliance | Designed to support ASTM D2196, ISO 2555, and USP <911> viscosity testing protocols |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP1000+, CAP2000+ |
| Instrument Type | Rotational Viscometer (Cone-Plate Geometry) |
| Torque Range | High Torque (181,000 dyne·cm) / Low Torque (7,970 dyne·cm) |
| Shear Rate Range | 0.2–15,000 s⁻¹ (dependent on cone spindle and speed selection) |
| Sample Volume | 24–1700 µL |
| Temperature Control | L-Series (5–75°C), H-Series (50–235°C) |
| Display | 4-line LCD |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Software | CapCalc32 (PC-based control, data acquisition, rheological modeling) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV2T |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1 to 320 × 10⁶ mPa·s (cP) |
| Speed Control | 0.01–200 rpm (200 programmable increments) |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Temperature Measurement | Integrated RTD probe (±0.1 °C typical) |
| Display | 5-inch full-color touchscreen |
| Compliance | FDA 21 CFR Part 11 (electronic signatures, user access levels, audit trail) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DV1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Accuracy | ±1.0% of full-scale reading |
| Repeatability | ±0.2% |
| Speed Control | 18 programmable RPM settings (0.3–100 rpm) |
| Display | Large-font, multi-parameter digital LCD |
| Languages | English, Chinese, French, German, Spanish, Portuguese, Russian |
| Interface | USB (compatible with optional Wingather SQ software) |
| Temperature Measurement | Optional RTD probe (DVP-94Y, requires specification at time of order) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model Variants | LVT, RVT, HAT, HBT |
| Instrument Type | Rotational Viscometer (Analog Dial) |
| Viscosity Range | 1–64 × 10⁶ mPa·s (cP) |
| Accuracy | ±1% of full-scale range |
| Repeatability | ±0.2% |
| Operating Temperature | Ambient |
| Motor Type | Low-noise DC motor |
| Compliance | UL Class 1, Group D (explosion-proof variants available without motor) |
| Standard Accessories | Instrument body, set of spindles, support stand, guard leg, carrying case |
| Compatibility | Fully compatible with all Brookfield accessories (e.g., UL Adapter, thermosel systems, small sample adapters) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | VTE |
| Instrument Type | In-line Viscometer |
| Viscosity Range | 10–10,000 cP |
| Output Signal | 4–20 mA (linear) |
| Accuracy | ±1% of full scale |
| Control Relay | 3 A solenoid-type |
| Enclosure Rating | NEMA 1 |
| Operating Environment | Ambient temperature |
| Compliance | Designed for continuous industrial process monitoring |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Model | V•Pad |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–320,000,000 cP |
| Repeatability | ±0.20% |
| Accuracy | ±1% of full scale |
| Temperature Range | −40 °C to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Probe | PT100, Class A |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Spindle Material | AISI 316 stainless steel |
| Compliance | ASTM D1076, D1084, D1286, D1417, D1439, D1638, D1824, D2196, D2336, D2364, D2393, D2556, D2669, D2849, D2983, D2994, D3232, D3236, D3716 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FAST |
| Instrument Type | In-line Viscometer |
| Application Environment | High-Temperature Process |
| Viscosity Range | 0–10, 0–50, 0–100, 0–250, 0–500, 0–1000, 0–1500 cSt |
| Temperature Range | –20°C to 120°C (–4°F to 248°F) |
| Measurement Principle | Torsional Resonance (Vibrational Shear) |
| Repeatability | ±1.0% of reading |
| Wetted Materials | 316L Stainless Steel |
| Sealing Material | Fluoroelastomer (FKM) O-rings (EDPM or Kalrez® optional) |
| Pressure Rating | Vacuum to 200 psig |
| Enclosure | NEMA-4 (IP65), Wall-Mounted Electronics Housing |
| Output | Dual 4–20 mA (Viscosity + Temperature), RS232 & RS485 (Modbus RTU), Optional Hazardous Area Certifications (NEMA 7 / ATEX), Optional 3A Sanitary Compliance |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | DVNext |
| Instrument Type | Rotational Viscometer/Rheometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–320 million cP (mPa·s) |
| Temperature Control | External (via AP/SD Series Circulators or High-Temp Systems) |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 1 °C |
| Speed Range | 0.01–250 RPM (2,600 programmable increments) |
| Compliance | FDA 21 CFR Part 11 (Regulatory-Ready Firmware & Audit Trail) |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Expert |
| Instrument Type | Rotational Viscometer |
| Speed Range | 0.01–200 rpm |
| Number of Speeds | 54 |
| Accuracy | ±1% of full scale |
| Repeatability | 0.2% |
| Temperature Range | 0–100 °C (32–212 °F) |
| PT100 Probe Accuracy | ±0.1 °C |
| Resolution | 0.1 °C / 0.17 °F |
| Viscosity Range (L-model) | 20–6,000,000 cP |
| Viscosity Range (R-model) | 100–40,000,000 cP |
| Viscosity Range (H-model) | 200–106,000,000 cP |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | ASTM D1084, D1286, D1439, D2196, D2393, D2556, D2849, ISO 2555, ISO 1652, BS 6075, BS 5350 |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Model | EVO Expert L/R/H |
| Viscosity Range | 20–106,000,000 cP (mPa·s) |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.01–200 rpm |
| Number of Speeds | 54 |
| Compliance | ASTM D1076, D1439, D2196, D2556, D2983, ISO 2555, BS 6075 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Interface | USB 2.0, Wi-Fi (optional), TFT color touchscreen, capacitive touch keypad |
| Data Output | Excel-compatible .csv/.xlsx via FDB software or built-in data logger |
| Calibration | User-accessible viscosity & temperature calibration with PT100 probe |
| Rotors | AISI 316 stainless steel, coded for rapid identification |
| Software | FDB Control Suite (Windows-based), GLP-compliant audit trail, multi-step program storage (up to 9), real-time graphing, shear rate/shear stress calculation (with coaxial rotor geometry) |
| Brand | Fungilab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | V•Compact |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–230,000,000 cP |
| Repeatability | ±0.2% |
| Accuracy | ±1% of full scale |
| Temperature Range | −40 °C to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Probe | PT100, Class A |
| Power Supply | 90–240 VAC, 50/60 Hz |
| Spindle Material | AISI 316 Stainless Steel |
| Speed Range | 0.01–250 rpm |
| Spindle Options | L (Low), R (Regular), H (High) configurations |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Lovis 2000 M/ME |
| Instrument Type | Falling Ball Viscometer |
| Mounting | Benchtop (Fixed) |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 mPa·s to 10,000 mPa·s |
| Temperature Range | +5 °C to 100 °C |
| Sample Volume | 100 µL (minimum) |
| Tilt Angle Range | 15° to 80° (1° increments) |
| Shear Rate Range | 0.5 s⁻¹ to 1,000 s⁻¹ |
| Viscosity Repeatability | ≤ 0.1 % (std. dev.) |
| Viscosity Accuracy | ≤ 0.5 % |
| Temperature Repeatability | ±0.005 °C |
| Temperature Accuracy | ±0.02 °C |
| Timing Resolution | 0.001 s |
| Timing Accuracy | ±0.05 % |
| Measurement Time | As low as 30 s (typical: 3 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SVM™ 2001 / SVM™ 3001 / SVM™ 4001 |
| Viscosity Range | 0.2 to 30,000 mm²/s |
| Temperature Range | +15 °C to +100 °C (SVM™ 2001 & 4001) |
| Density Range | 0.6 to 3.0 g/cm³ |
| Sample Volume | 1.5–6 mL |
| Compliance | ASTM D7042, ISO 12185, EN 16896, ASTM D4052, ISO 2909, ASTM D2270, ISO 91, ASTM D1250, ASTM D2161 |
| Cooling | Integrated Peltier (down to –20 °C) |
| Power | AC 100–240 V, 50–60 Hz, max. 250 VA |
| Dimensions (W × D × H) | 33 × 51 × 23.1 cm |
| Net Weight | 15.9–17.8 kg |
Show next