- All
- Favorite
- Popular
- Most rated
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3052 |
| Measurement Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm (auto-ranging) |
| Resolution | 0.1 ppm |
| Accuracy | ≤ ±2% FS |
| Response Time (T90) | ≤ 10 s |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH |
| Analog Outputs | 4–20 mA, 0–1 V / 0–5 V / 0–10 V DC |
| Alarm Outputs | 2 configurable O₂ alarms + 1 fault alarm |
| Communication Interfaces | RS-232, RS-485 |
| Power Supply | 12 V DC or 20 V AC, 50 Hz |
| Dimensions (Analyzer) | 178 × 107 × 95 mm (L×W×H) |
| Sensor Dimensions | Ø38.1 × 71.5 mm (D×L) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | 0.01% |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Power Supply | 100–240 VAC, 100 W |
| Output | RS-485/RS-232, (4–20) mA |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Response Time | T90 ≤ 1 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5 %vol, customizable to 100 %vol), CO (0–100 %vol), CO₂ (0–100 %vol), CH₄ (0–20 %vol) |
| Resolution | 0.01 %vol |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature Range | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3110 |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db |
| Measurement Principle | TDLAS (Transmittance Configuration) |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5% vol, optional up to 100%), CO (0–100% vol), CO₂ (0–100% vol), CH₄ (0–20% vol) |
| Resolution | 0.01% vol |
| Ambient Temperature Range | −20 to +60 °C |
| Power Supply | 220 V AC, 50 Hz |
| Sample Gas Pressure | 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × Relay |
| Communication | RS485, RS232 |
| Sample Conditioning | Multi-stage filtration, automatic probe purge, condensate drainage |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 %FS |
| Repeatability | ≤ ±1 %FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial N₂, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard 3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Response Time | <40 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Output Signals | RS-485 / RS-232 / 4–20 mA |
| Display | LCD |
| Power Supply | AC 220 V, 50 Hz |
| Auto-Zero Function | Integrated air pump for in-situ zero calibration |
| Diagnostic Capability | Real-time sensor health monitoring |
| Preconditioning | Integrated front-end sample conditioning for wet, dusty, and oily gas streams |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1% F.S. |
| H₂/O₂ | ±2% F.S. |
| Span Drift | CO/CO₂/CH₄/H₂: (0–100)% |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7900M |
| Measurement Principle | Transit-time ultrasonic velocity sensing |
| Accuracy | ≤ ±1.5% F.S. |
| Pipe Diameter Range | ≥ 0.3 m |
| Velocity Range | 0–40 m/s |
| Temperature Range (Flue Gas) | −20 to 480 °C |
| Pressure Range (Flue Gas) | −10 to +10 kPa |
| Output Signals | 4–20 mA, RS-485 |
| Enclosure Rating | IP65 |
| Power Supply (Main Unit) | AC 220 V ±10%, 50/60 Hz |
| Blower Power | AC 220 V ±10%, 50/60 Hz, 280 W |
| Weight | 28 kg |
| Channel Configuration | Single-channel (optional dual- or quad-channel) |
| Media Compatibility | Non-flammable gases (e.g., flue gas, air) |
| Minimum Detectable Velocity | 0.1 m/s |
| Materials | Corrosion-resistant alloys for wetted components |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-O2 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Range | O₂: 0–5% vol (customizable up to 100% vol) |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤±1% F.S. |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Environmental Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Exd II CT6 |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Purge Gas Requirement | Industrial nitrogen, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Display | LCD |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM6208D |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–2000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | ≤30 s |
| Warm-up Time | <180 s |
| Output Signal | 4–20 mA / 0–10 V (selectable) |
| Operating Temperature | −10 to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 24 VAC ±10% or 24 VDC ±10% |
| Average Current Consumption | ≤40 mA |
| Standby Current | ≤20 mA |
| Mounting Hole Pitch | 60 mm |
| Dimensions | 86 × 120 × 185 mm |
| Service Life | ≥15 years |
| Compliance | RoHS, CE (EMC & LVD), ISO 9001-manufactured |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CUBIC-LGA-TDLAS |
| Price | Upon Request |
| Linearity Error | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Measurement Range | 0–10,000 ppm |
| Response Time | <40 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | ±1% FS (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm) |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3052 |
| Measurement Range | 0–10 ppm / 0–100 ppm / 0–1000 ppm (auto-ranging) |
| Resolution | 0.1 ppm |
| Accuracy | ≤±2% FS |
| Repeatability | ≤±2% FS |
| Response Time (T90) | ≤10 s |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Output Signals | 4–20 mA, 0–1 V / 0–5 V / 0–10 V DC |
| Alarm Outputs | 2 configurable alarm relays + 1 fault relay |
| Communication Interfaces | RS-232, RS-485 |
| Power Supply | 12 V DC or 20 V AC, 50 Hz |
| Dimensions (Analyzer) | 178 × 107 × 95 mm (L×W×H) |
| Sensor Dimensions | Ø38.1 × 71.5 mm (D×L) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Range Drift | CO/CO₂/CH₄/H₂: (0–100)% |
| Response Time | T90 < 15 s (NDIR) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard 3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Accuracy | ±0.5–2% F.S. (gas- and range-dependent) |
| Resolution | 0.01% vol to 1 ppm |
| Response Time | <40 s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-3500 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gases | O₂, CO, CO₂, H₂S, CH₄ |
| Detection Ranges | O₂ (0–100% vol, down to 1 ppm), CO (0–100% vol, down to 0.1 ppm), CO₂ (0–100% vol, down to 0.1 ppm), H₂S (0–1% vol, down to 0.1 ppm), CH₄ (0–100% vol, down to 0.1 ppm) |
| Accuracy | ±0.5–2% F.S. depending on gas and range |
| Response Time | <40 s (at 2 L/min) |
| Sample Flow Rate | 0.7–1.2 L/min (optimal), up to 2 L/min |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA analog |
| Power Supply | AC 220 V, 50 Hz |
| Display | Integrated LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | CUBIC-LGA Series |
| Linearity Error | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Measurement Range | 0–10,000 ppm |
| Response Time | <40 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±1 % FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Communication | RS485, RS232 |
| Analog Outputs | 2 × 4–20 mA |
| Digital Outputs | 3 × relay |
| Installation | In-situ (transmission path) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GasTDL-3110 |
| Pricing | Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 % FS |
| Response Time (T90) | ≤ 1 s |
| Repeatability | ≤ ±1 % FS |
| Resolution | 0.01 %vol |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Communication | RS485, RS232 |
| Analog Outputs | 2 × 4–20 mA |
| Digital Outputs | 3 × relay |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM6208W |
| Measurement Principle | NDIR (Non-Dispersive Infrared) |
| Measurement Range | 0–2000 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Resolution | 1 ppm |
| Refresh Rate | 1 s |
| Warm-up Time | <180 s |
| Response Time (T90) | ≤30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −20 to 70 °C |
| Supply Voltage | 24 VAC ±10% or 24 VDC ±10% |
| Average Current Consumption | ≤40 mA |
| Standby Current | ≤20 mA |
| Output Signal | 4–20 mA / 0–10 V (configurable) |
| Mounting Hole Pitch | 60 mm |
| Dimensions | 86 × 86 × 24.9 mm |
| Service Life | ≥15 years |
| Compliance | RoHS, CE-marked for industrial use |
| Calibration | ABC (Automatic Background Calibration) enabled |
Show next