| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | 0.01% |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Power Supply | 100–240 VAC, 100 W |
| Output | RS-485/RS-232, (4–20) mA |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Sampling Method | In-situ |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Response Time | T90 ≤ 1 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5 %vol, customizable to 100 %vol), CO (0–100 %vol), CO₂ (0–100 %vol), CH₄ (0–20 %vol) |
| Resolution | 0.01 %vol |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature Range | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3110 |
| Linearity Error | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Span Drift | ≤±1% F.S. |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db |
| Measurement Principle | TDLAS (Transmittance Configuration) |
| Measured Gases | H₂S (0–100 ppm / 0–5000 ppm), O₂ (0–5% vol, optional up to 100%), CO (0–100% vol), CO₂ (0–100% vol), CH₄ (0–20% vol) |
| Resolution | 0.01% vol |
| Ambient Temperature Range | −20 to +60 °C |
| Power Supply | 220 V AC, 50 Hz |
| Sample Gas Pressure | 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × Relay |
| Communication | RS485, RS232 |
| Sample Conditioning | Multi-stage filtration, automatic probe purge, condensate drainage |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9031EX |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1% F.S. |
| H₂/O₂ | ±2% F.S. |
| Span Drift | CO/CO₂/CH₄/H₂: (0–100)% |
| Explosion Protection Rating | Ex d IIC T4 Gb |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CUBIC-LGA-TDLAS |
| Price | Upon Request |
| Linearity Error | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Measurement Range | 0–10,000 ppm |
| Response Time | <40 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | ±1% FS (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm) |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Flow Range | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Range Drift | CO/CO₂/CH₄/H₂: (0–100)% |
| Response Time | T90 < 15 s (NDIR) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | CUBIC-LGA Series |
| Linearity Error | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Measurement Range | 0–10,000 ppm |
| Response Time | <40 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power | 100–240 VAC, 100 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CUBIC-LGA Series |
| Price | Upon Request |
| Linearity Error | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Measurement Range Drift | 0–10,000 ppm |
| Response Time | <40 s |
| Explosion Protection Rating | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Not Applicable |
| Price | Upon Request |
| Linearity Error | ±2% F.S. |
| Repeatability | ±2% F.S. |
| Response Time (T90) | <10 s |
| Measurement Ranges | CO₂: 0–5,000 ppm |
| CO | 0–30% vol |
| CH₄ | 0–10% vol |
| Resolution | CO₂: 0.1 ppm |
| CO | 0.01% vol |
| CH₄ | 0.01% vol |
| Accuracy | ±2% F.S. for all gases |
| Stability | ≤±2% per month |
| Response Time (T90) | ≤30 s |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Sampling Method | Extractive Online Analysis |
| Linearity Error | ±1% FS for CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm |
| Repeatability | ≤1% |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)% |
| O₂ | (0–25)% |
| C₂H₂/C₂H₄/CnHm | (0–10)% (optional) |
| Resolution | 0.01% |
| Optimal Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Output | RS-485/RS-232, (4–20) mA |
| Power Supply | 100–240 VAC, 100 W |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Linear Error | CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm: ±1% FS |
| O₂/H₂ | ±2% FS |
| Repeatability | ≤1% |
| Response Time | T90 < 15 s (NDIR) |
| Measurement Principle | NDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂) |
| Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Output | RS-485/RS-232, 4–20 mA |
| Power Supply | 100–240 VAC, 100 W |