- All
- Favorite
- Popular
- Most rated
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 %FS |
| Repeatability | ≤ ±1 %FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial N₂, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-O2 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Range | O₂: 0–5% vol (customizable up to 100% vol) |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤±1% F.S. |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Environmental Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Exd II CT6 |
| Output Signals | 2 × 4–20 mA, 3 × relay outputs |
| Communication Interface | RS485, RS232 |
| Purge Gas Requirement | Industrial nitrogen, 0.3–0.8 MPa |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±1 % FS |
| Resolution | 0.01 %vol |
| Response Time (T90) | ≤ 1 s |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Power Supply | 24 V DC, 24 W |
| Ambient Temperature | −20 to +60 °C |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Communication | RS485, RS232 |
| Analog Outputs | 2 × 4–20 mA |
| Digital Outputs | 3 × relay |
| Installation | In-situ (transmission path) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | H₂S: 0–100 ppm / 0–5000 ppm |
| O₂ | 0–5 %vol (customizable up to 100 %vol) |
| CO | 0–100 %vol |
| CO₂ | 0–100 %vol |
| CH₄ | 0–20 %vol |
| Accuracy | ≤ ±1 % FS |
| Response Time (T90) | ≤ 1 s |
| Repeatability | ≤ ±1 % FS |
| Resolution | 0.01 %vol |
| Explosion Protection | Exd II CT6 Gb / Ex tb IIIC T80°C Db |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Communication | RS485, RS232 |
| Analog Outputs | 2 × 4–20 mA |
| Digital Outputs | 3 × relay |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Sensor Type | Electrochemical (ECD) |
| Measurement Ranges | 0–1% O₂ / 0–5% O₂ / 0–25% O₂ |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ ±1% FS |
| Linearity Error | ≤ ±1% FS |
| Resolution | 0.1% (for 0–25% range) or 0.01% (for 0–1% range) |
| Response Time (T90) | < 30 s |
| Explosion Protection Rating | Ex db IIC T6 Gb |
| Operating Temperature | −20 to +60 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Output Signal | RS485 (standard, Modbus RTU protocol) or RS232 (optional) |
| Power Supply | 24 VDC or 220 VAC |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9300 |
| Sensor Type | Tunable Diode Laser (TDLAS) |
| Measurement Ranges | 0–1%, 0–5%, 0–25% O₂ (selectable) |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Linearity Error | ≤ ±1% FS |
| Resolution | 0.1% (for 0–25% range) or 0.01% (for 0–1% range) |
| Response Time (T90) | < 10 s |
| Explosion Protection Rating | Ex db IIC T6 Gb |
| Operating Temperature | −20 to +60 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Output Signal | RS485 (standard), RS232 (optional) |
| Communication Protocol | Modbus RTU |
| Power Supply | 24 VDC or 220 VAC |
Show next