BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100
Sensor TypeTunable Diode Laser (TDLAS)
Measurement RangesH₂S: 0–100 ppm / 0–5000 ppm
O₂0–5 %vol (customizable up to 100 %vol)
CO0–100 %vol
CO₂0–100 %vol
CH₄0–20 %vol
Accuracy≤ ±1 %FS
Repeatability≤ ±1 %FS
Resolution0.01 %vol
Response Time (T90)≤ 1 s
Explosion ProtectionExd II CT6 Gb / Ex tb IIIC T80°C Db
Power Supply24 V DC, 24 W
Ambient Temperature−20 to +60 °C
Purge GasIndustrial N₂, 0.3–0.8 MPa
Output Signals2 × 4–20 mA, 3 × relay
CommunicationRS485, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100-O2
Sensor TypeTunable Diode Laser (TDLAS)
Measurement RangeO₂: 0–5% vol (customizable up to 100% vol)
Accuracy≤±1% F.S.
Repeatability≤±1% F.S.
Resolution0.01% vol
Response Time (T90)≤4 s
Environmental Operating Temperature−20 to +60 °C
Power Supply24 V DC, 24 W
Explosion ProtectionExd II CT6
Output Signals2 × 4–20 mA, 3 × relay outputs
Communication InterfaceRS485, RS232
Purge Gas RequirementIndustrial nitrogen, 0.3–0.8 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100
Sensor TypeTunable Diode Laser (TDLAS)
Measurement RangesH₂S: 0–100 ppm / 0–5000 ppm
O₂0–5 %vol (customizable up to 100 %vol)
CO0–100 %vol
CO₂0–100 %vol
CH₄0–20 %vol
Accuracy≤ ±1 % FS
Repeatability≤ ±1 % FS
Resolution0.01 %vol
Response Time (T90)≤ 1 s
Explosion ProtectionExd II CT6 Gb / Ex tb IIIC T80°C Db
Power Supply24 V DC, 24 W
Ambient Temperature−20 to +60 °C
Purge GasIndustrial nitrogen, 0.3–0.8 MPa
CommunicationRS485, RS232
Analog Outputs2 × 4–20 mA
Digital Outputs3 × relay
InstallationIn-situ (transmission path)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100
Sensor TypeTunable Diode Laser (TDLAS)
Measurement RangesH₂S: 0–100 ppm / 0–5000 ppm
O₂0–5 %vol (customizable up to 100 %vol)
CO0–100 %vol
CO₂0–100 %vol
CH₄0–20 %vol
Accuracy≤ ±1 % FS
Response Time (T90)≤ 1 s
Repeatability≤ ±1 % FS
Resolution0.01 %vol
Explosion ProtectionExd II CT6 Gb / Ex tb IIIC T80°C Db
Operating Temperature−20 to +60 °C
Power Supply24 V DC, 24 W
Purge GasIndustrial nitrogen, 0.3–0.8 MPa
CommunicationRS485, RS232
Analog Outputs2 × 4–20 mA
Digital Outputs3 × relay
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Sensor TypeElectrochemical (ECD)
Measurement Ranges0–1% O₂ / 0–5% O₂ / 0–25% O₂
Accuracy≤ ±2% FS
Repeatability≤ ±1% FS
Linearity Error≤ ±1% FS
Resolution0.1% (for 0–25% range) or 0.01% (for 0–1% range)
Response Time (T90)< 30 s
Explosion Protection RatingEx db IIC T6 Gb
Operating Temperature−20 to +60 °C
Operating Humidity0–98% RH (non-condensing)
Output SignalRS485 (standard, Modbus RTU protocol) or RS232 (optional)
Power Supply24 VDC or 220 VAC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9300
Sensor TypeTunable Diode Laser (TDLAS)
Measurement Ranges0–1%, 0–5%, 0–25% O₂ (selectable)
Accuracy≤ ±1% FS
Repeatability≤ ±1% FS
Linearity Error≤ ±1% FS
Resolution0.1% (for 0–25% range) or 0.01% (for 0–1% range)
Response Time (T90)< 10 s
Explosion Protection RatingEx db IIC T6 Gb
Operating Temperature−20 to +60 °C
Operating Humidity0–98% RH (non-condensing)
Output SignalRS485 (standard), RS232 (optional)
Communication ProtocolModbus RTU
Power Supply24 VDC or 220 VAC