| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Detection Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | CH₄/CO₂/CO/N₂O ≤ ±1% F.S. |
| Repeatability | ≤ ±1% F.S. |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s |
| Linearity Error | CH₄/CO₂/CO/N₂O ≤ ±1% F.S. |
| Operating Flue Gas Temp. | 0–300 °C |
| Heated Line & Probe Temp. | 120–180 °C |
| Protection Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Ambient Humidity | < 95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, moisture-free |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Sample Flow Rate | Max. 2 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Measurement Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical Detection (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Repeatability | ≤±1% F.S. |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T90) | <25 s |
| Linearity Error | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Sample Temperature Limit | 0–300 °C |
| Heated Sampling Line & Probe Temp | 120–180 °C |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp | −20 to +50 °C |
| Ambient Humidity | <95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, dry |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Diagnostic Features | Real-time sensor health monitoring, automatic zero calibration via integrated air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-3000Plus |
| Instrument Type | Online Fixed-Mount Analyzer |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Range | SO₂/NO: (0–200) ppm |
| CO | (500–5000) ppm |
| CO₂/O₂ | (0–25) % vol |
| Repeatability | < 2% |
| Resolution | SO₂/NO: 1 ppm |
| CO | 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s (NDIR channels) |
| Linearity Error | ≤ ±2% F.S. |
| Sample Flow Rate | (0.7–1.2) L/min |
| Output Interfaces | RS-485 / RS-232 serial, (4–20) mA analog |
| Power Supply | 100–240 VAC, 150 W |
| Detection Principle | Micro-Flow NDIR (SO₂, NO, CO), Broadband NDIR (CO₂), Electrochemical Detection (O₂) |
| Zero Calibration | Integrated air pump with automatic ambient-air zeroing |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | GasTDL-3100-CO |
| Instrument Type | In-situ online analyzer |
| Measured Gas | CO (primary), with optional multi-component capability (O₂: 0–5% vol, CO₂: 0–100% vol, CH₄: 0–20% vol) |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤±1% |
| Resolution | 0.01% vol |
| Response Time (T90) | ≤4 s |
| Span Drift | ≤±1% F.S. |
| Linearity Error | ≤±1% F.S. |
| Operating Temperature | −20 to +60 °C |
| Power Supply | 24 V DC, 24 W |
| Explosion Protection | Exd II CT6 |
| Purge Gas | Industrial nitrogen, 0.3–0.8 MPa |
| Output Signals | 2 × 4–20 mA, 3 × relay |
| Communication | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000GHG |
| Instrument Type | Online Analyzer |
| Detection Targets | CO₂, CH₄, N₂O, CO, O₂ |
| Measurement Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (CO₂/CO), Electrochemical (O₂) |
| Range (CO₂, micro-flow) | 0–500 ppm / 0–20% |
| Range (CH₄/N₂O) | 0–1000 ppm |
| Range (CO, micro-flow) | 0–200 ppm / 0–5000 ppm |
| Range (CO, dual-beam) | 0–1% / 0–5% |
| Range (O₂) | 0–25% |
| Resolution | 1 ppm (low-range gases), 0.01% (high-range gases), 0.001% (CO dual-beam) |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Repeatability | ≤±1% |
| Response Time (T90) | <25 s |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Conditioning | Water removal (no condensation), particulate filtration (<1 µm) |
| Output | RS-485 / RS-232, (4–20) mA |
| Power Supply | 100–240 VAC, max. 300 W (heating), 100 W (steady-state) |
| Diagnostic Function | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Detection Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s |
| Linearity Error | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Flue Gas Temp. Limit | 0–300 °C |
| Sample Line & Probe Heating | 120–180 °C |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Ambient Humidity | < 95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, dry |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Built-in Zero Calibration | Air auto-zero via integrated zero-air pump |
| Self-Diagnostic Capability | Real-time sensor health monitoring |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800GHG |
| Instrument Type | Portable |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Measurement Principle | Micro-flow NDIR (CO₂/CH₄/N₂O/CO), Dual-beam NDIR (CO₂/CO, high-range), Electrochemical (O₂) |
| Range (CO₂) | 0–500 ppm / 0–20% / 0–100% (configurable) |
| Range (CH₄/N₂O) | 0–1000 ppm |
| Range (CO) | 0–200 ppm / 0–5000 ppm / 0–5% |
| Range (O₂) | 0–25% |
| Accuracy | ±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD) |
| Repeatability | ≤±1% |
| Response Time (T90) | <25 s |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output | USB, analog (4–20 mA), printer interface |
| Power | 100–240 VAC, 150 W |
| Self-diagnostic Function | Yes |