| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3050-D |
| Measurement Principle | Ceramic Zirconia Electrolyte (O₂), Derived H₂O Calculation via O₂/H₂O Correlation |
| H₂O Range | 0–40 %v/v |
| O₂ Range | 0.1–25 %v/v |
| Accuracy | ±2 %F.S. (H₂O & O₂) |
| Repeatability | ±2 % |
| Sample Temp. Limit | ≤ 180 °C |
| Output | Dual 4–20 mA, RS485 (standard), RS232 (optional), 3 x Relay Outputs |
| Power | 24 V DC, 50 W |
| Installation | Wall-mounted probe + DIN-rail instrument housing |
| Enclosure | Non-explosion-proof |
| Operating Ambient | −10 to +50 °C, <90 %RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3006UV |
| Measurement Principle | UV DOAS |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤1% |
| Response Time | T₉₀ ≤30 s at 1 L/min |
| Stability | ≤±1.5% F.S./24 h |
| Linear Error | ≤±1% F.S. |
| Sample Flow Rate | 0.7–1.2 L/min |
| Display | 7-inch color TFT touchscreen (800×480) |
| Dimensions (W×H×D) | 438×173×350 mm |
| Power Supply | 100–240 VAC, 100 W |
| Communication | Dual RS232/RS485, 4–20 mA analog output |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤2% F.S. |
| Repeatability | ≤2% |
| Response Time | ≤30 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principles | Micro-flow NDIR (SO₂/NO/CO), Broadband NDIR (CO₂), Electrochemical Detection (O₂) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Dimensions | 275 × 470 × 175 mm |
| Weight | 7.5 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂, NO, NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtered (<1 µm) |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800UV |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time | T90 < 15 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3600UV |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NO₂ |
| Range | 0–500 mg/m³ (each) |
| Accuracy | ≤±2% F.S. |
| Repeatability | ≤1% |
| Response Time | ≤30 sec @ T90 |
| Detection Limit | 0.01 mg/m³ (SO₂/NO/NO₂) |
| Sample Method | Hot-Wet Extraction |
| Optical Path | Multi-reflection long-path cell |
| Light Source | Pulsed Xenon Lamp |
| Measurement Chamber Temp. | 120–190 °C (adjustable) |
| Zero Drift | ≤2% F.S./24 h |
| Span Drift | ≤2% F.S./24 h |
| Communication | RS-232 / RS-485 |
| Power Supply | 220 VAC / 50 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Measurement Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Measurands | CH₄, CO₂, CO, N₂O, O₂ |
| Accuracy | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <25 s |
| Detection Limits | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Flue Gas Temp. Range | 0–300 °C |
| Heated Line & Probe Temp. | 120–180 °C |
| Protection Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Humidity | <95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, moisture-free |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Gasboard-3000 |
| Instrument Type | Multi-Gas Continuous Emission Monitoring (CEM) Analyzer |
| Measurement Accuracy | SO₂, NO, CO: ±1 ppm |
| CO₂, O₂ | ±0.01% |
| Repeatability | ≤1% for SO₂, NO, CO, CO₂, O₂ |
| Response Time | T₉₀ < 10 s (NDIR channels) |
| Stability | SO₂, NO, CO, CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3201Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±0.2% FS (O₂, CO₂) |
| Response Time | T₉₀ < 30 s (O₂, SO₂, CO₂), T₉₀ < 40 s (CO, NO), T₆₀ < 30 s (SO₂) |
| Measured Gases | O₂, CO, NO, SO₂, CO₂ |
| Gas Detection Principle | Electrochemical (O₂, CO, NO, SO₂), NDIR (CO₂) |
| Operating Temperature | –5 °C to +45 °C |
| Display | 5.5-inch HD touchscreen (720 × 1280 px) |
| Battery | Rechargeable Li-ion, 3.7 V / 6400 mAh |
| Data Storage | Internal memory for 2000 measurement sets |
| Connectivity | Bluetooth 5.0 for mobile app and wireless printer |
| Compliance | Designed to support EPA Method 6C, ISO 12039, EN 15267-3, and GLP-compliant data logging with timestamped audit trail |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Measurement Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm: (0–10)% (optional) |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), ±2% FS (O₂/H₂) |
| Repeatability | ≤1% |
| Response Time (T90) | <15 s (NDIR) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Resolution | 0.01% |
| Output | RS-485/RS-232, 4–20 mA |
| Power Supply | 100–240 VAC, 100 W |
| Display | LCD |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Auto-Zero | Built-in air pump |
| Diagnostics | Real-time sensor health monitoring |
| Sample Requirements | Dust-free, moisture-free, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-situ Flue Gas Oxygen Analyzer |
| Repeatability | ≤±1% FS |
| Response Time | T90 < 15 s |
| Stability | ±2% FS / 7 days |
| Measured Gas | O₂ |
| Measurement Range | 0–25% vol |
| Resolution | 0.1% vol |
| Accuracy | ±2% FS |
| Sampling Method | Direct-insertion, flow-guided probe |
| Operating Temperature | 0–700 °C |
| Enclosure Rating | IP65 |
| Output Signals | RS-485 & 4–20 mA |
| Power Supply | DC 24 V ±10%, 2 A |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Display | 128×160 color LCD |
| Alarm Outputs | 2 relay channels |
| Calibration | Field-calibratable with ambient air or certified O₂ standard gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000 |
| Measurement Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical (O₂) |
| Measurement Range | SO₂/NO: 0–2000 ppm |
| CO | 0–10000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | SO₂/NO/CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Repeatability | ≤1% |
| Response Time (T₉₀) | <20 s (NDIR) |
| Zero Drift Stability | SO₂/NO/CO/CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD with built-in diagnostics and auto-zero function using integrated air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2520 |
| Detection Gases | O₂, CO, CO₂, H₂S, CH₄, C₂H₂, HF |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <30 s |
| Accuracy | ±1–2% F.S. (gas-dependent) |
| Resolution | 1 ppm (O₂, CO, H₂S, etc.), 0.01% (CO₂), 0.1 ppm (HF) |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 0–98% RH (non-condensing) |
| Power Supply | 12 V ±10% |
| Output Interface | RS-232 / RS-485 |
| Constant-Temperature Control | 50 °C ±0.5 °C |
| Dimensions (L×W×H) | 278 × 90 × 70 mm |
| Weight | ~1.2 kg |
| Compliance | Designed for industrial emission monitoring per ISO 14064-1 and EN 15267-3 pre-certification requirements |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000 |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical Detection (O₂) |
| Range | SO₂/NO: 0–2000 ppm |
| CO | 0–10,000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | SO₂/NO/CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% |
| Repeatability | ≤1% |
| Response Time (T90) | <10 s (NDIR) |
| Zero Drift Stability | SO₂/NO/CO/CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD with self-diagnostic interface |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9070 |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NH₃ |
| Measurement Range (SO₂) | 0–1000 mg/m³ (desulfurization inlet), 0–50 mg/m³ (emission stack) |
| Measurement Range (NO) | 0–100 mg/m³ (inlet), 0–50 mg/m³ (emission) |
| Measurement Range (NH₃) | 0–20 mg/m³ (both inlet & outlet) |
| Accuracy | ≤ ±2% F.S. |
| Repeatability | ≤ 1% |
| Response Time (T₉₀) | ≤ 60 s |
| Resolution | 0.1 ppm |
| Operating Ambient Temperature | 0–50 °C |
| Power Supply | 220 V AC, 800 W |
| Purge Air Pressure | 0.4–0.8 MPa |
| Analog Outputs | 4 × 4–20 mA |
| Digital Outputs | 8 × relay |
| Communication Interfaces | RS485, RS232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Gases | CO, CO₂, O₂, SO₂, NO, Flue Gas Temperature |
| Measurement Principle | NDIR (CO, CO₂), Electrochemical (O₂, SO₂, NO), K-type Thermocouple (Temperature) |
| Range | CO/NO: 0–2000 ppm |
| SO₂ | 0–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% F.S. (all gases), ±3°C (temperature) |
| Repeatability | ≤2% |
| Response Time (T90) | <20 s (NDIR) |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Power | Rechargeable Li-ion battery, 12.6 V external charger |
| Communication | RS485 / RS232 |
| Features | Integrated temperature-compensated sampling probe, auto-diagnostic function, built-in imported sampling pump, data logging with query/delete capability |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3000 |
| Instrument Type | Multi-Component Flue Gas Analyzer |
| Measurement Accuracy | SO₂, NO, CO: ±1 ppm |
| CO₂, O₂ | ±0.01% |
| Repeatability | ≤1% for SO₂, NO, CO, CO₂, O₂ |
| Response Time (T90) | <10 s (NDIR) |
| Stability | SO₂, NO, CO, CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂/NO/NO₂), Electrochemical (O₂) |
| Measurands | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | RS-232/RS-485 (Modbus RTU or customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂, NO, NO₂) |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Communication | Dual RS-232/RS-485, Modbus RTU or customizable protocol |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂/NO/NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485 ports, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. (SO₂, NO, CO, CO₂, O₂) |
| Repeatability | ≤2% |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Detection Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical (O₂) |
| Temperature Range | 0–800 °C |
| Flow Velocity Range | 3–40 m/s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3400P |
| Measurement Principle | NDIR for CO/CO₂ |
| Measured Parameters | CO (0–5000 ppm), CO₂ (0–25 % vol), O₂ (0–21 % vol), flue gas temperature (0–1200 °C) |
| Accuracy | CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| temperature | ±3 °C or ±1% of reading |
| Repeatability | ≤1% |
| Response Time (T90) | ≤15 s (NDIR) |
| Resolution | O₂: 0.01% vol |
| CO | 1 ppm |
| CO₂ | 0.01% vol |
| temperature | 0.1 °C |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 5–85% RH |
| Battery Life | >10 h (rechargeable Li-ion) |
| Communication | RS-232 / RS-485 |
| Expandable Sensors | SO₂, NO, NO₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-3000GHG |
| Instrument Type | Multi-Gas Flue Gas Analyzer |
| Repeatability | ≤±1% FS |
| Response Time (T90) | <25 s |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-Situ Flue Gas Oxygen Analyzer |
| Measurement Range | 0–25% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <15 s |
| Stability | ±2% F.S. / 7 days |
| Operating Temperature (Flue Gas) | 0–700 °C |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Sampling Method | Flow-guided direct insertion |
| Installation | DN40 flange mount |
| Enclosure Rating | IP65 |
| Display | 128×160 color LCD |
| Output Signals | RS-485 & 4–20 mA |
| Relay Outputs | 2 channels |
| Power Supply | DC 24 V ±10%, 2 A |