Empowering Scientific Discovery

Sinfon Optoelectronics (Wuhan) Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPM3003Q
PriceUSD 630 (FOB)
Operating PrincipleLaser Light Scattering
Safety RatingNon-Explosive Atmosphere Rated
Measurement Range0–50 mg/m³ (max display: 1000 mg/m³)
Accuracy±200 µg/m³ for 0–1 mg/m³
Detection PrincipleOptical Scattering
Recommended Sample Flow Rate2 L/min
Data Update Interval1 s
Operating Temperature30–70 °C
Operating Humidity5–95% RH (non-condensing)
Storage Temperature−40–85 °C
Storage Humidity0–95% RH (non-condensing)
Supply VoltageDC 5 V ± 0.2 V (ripple < 100 mV)
Average Current Consumption<150 mA
Standby Current<25 mA
InterfaceUART (TTL 3.3 V logic level)
Dimensions90.8 × 60.2 × 37.6 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelPM2008MSE
Detection PrincipleOptical Scattering (Laser Nephelometry)
Measurement Range0–1000 µg/m³ (PM1.0, PM2.5, PM10)
Resolution0.3 µm
Accuracy (PM2.5)±10 µg/m³ (≤100 µg/m³), ±10% of reading (>100 µg/m³)
Accuracy (PM10)±20 µg/m³ (≤100 µg/m³), ±20% of reading (>100 µg/m³)
Data Update Interval1 s
Warm-up Time≤8 s
Operating Temperature−10 to +50 °C
Relative Humidity0–95% RH (non-condensing)
Storage Conditions−20 to +60 °C, 0–95% RH
Supply VoltageDC 5 V ±0.1 V (ripple <50 mV)
Operating Current≤100 mA
Standby Current≤200 µA
InterfaceUART (3.3 V logic), I²C (3.3 V logic)
Dimensions48 × 40 × 12 mm (W × H × D)
ShieldingFull-metal EMI enclosure
DesignUltra-thin profile (12 mm height)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPM5000S
Operating PrincipleLight Scattering (Laser Nephelometry)
Safety RatingNon-Explosive Atmosphere Rated
Measurement Channels0.3, 0.5, 1.0, 2.5, 5.0, and 10.0 µm
Calibration ComplianceJJF 1190–2008 “Calibration Specification for Airborne Particle Counters”
Output FormatParticle concentration in pcs/L per channel
Sampling Flow Rate2.83 L/min (standard)
Detection Efficiency≥50% at 0.3 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGasboard-9056
Measurement PrincipleForward Light Scattering (Laser)
Safety RatingExplosion-Proof (Ex d IIB T4 Gb)
Measurement Range0–5 mg/m³
Resolution< 0.1 mg/m³
Accuracy±10% of reading
Relative Error≤ ±20%
Sampling MethodHeated Extractive Probe with Hot-Wet Return
Isokinetic Sampling CapabilityYes
Maximum Sampling Flow Rate200 L/min
Operating Environment-20°C to +60°C, RH ≤ 95% non-condensing, IP65 enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Measurement PrincipleOptical Light Scattering
Safety ClassificationNon-Explosion-Proof
Range0–20 mg/m³
Accuracy≤ ±10% F.S.
LOD0.01 mg/m³
Zero Drift±2% F.S./24h
Span Drift±2% F.S./24h
Operating Temp.−20 to 50°C
Humidity5–95% RH (non-condensing)
Flue Gas Temp. Tolerance<300°C
Data Update Rate1 Hz
Power SupplyDC 12 V ±0.5 V (ripple <100 mV)
Avg. Current Draw<500 mA
InterfaceUART_TTL (3.3 V logic)
Dimensions (W×H×D)272 × 111 × 193 mm
Anti-CloggingPneumatic Air Curtain Protection
Enclosure RatingIP65-equivalent (based on module integration context)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelPM3003S
Measurement PrincipleLaser Light Scattering (90° Detection Geometry)
Safety RatingExplosion-Proof (Ex ib IIB T4 Gb)
Measurement Range0–1000 µg/m³
AccuracyPM1.0: ±10 µg/m³ or ±10% of reading
PM2.5±10 µg/m³ or ±10% of reading
PM10±15 µg/m³ or ±15% of reading
TSP±20 µg/m³ or ±20% of reading
Sampling Flow Rate1.0 L/min (pump-assisted)
Data Refresh Interval1 s
Operating Temperature−30 °C to +70 °C
Relative Humidity0–95% RH (non-condensing)
Power SupplyDC 5.0 V ±0.1 V (ripple <50 mV)
Current Consumption<150 mA (operational), <25 mA (standby)
Output InterfacesAnalog voltage (0–5 V or 0–10 V configurable), UART TTL (3.3 V logic level)
Dimensions82 × 40.2 × 26.3 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelPM2107
PricingAvailable Upon Request
Operating PrincipleLaser Light Scattering
Measurement Range0–1000 µg/m³
Accuracy±15 µg/m³ or ±15% of reading
Detection PrincipleLaser Scattering
PM2.5 Range0–1000 µg/m³
Power-On Stabilization Time≤8 s
Data Update Interval1 s
Environmental Conditions (Calibration)25°C ±2°C, 50% RH ±10%, referenced to TSI AM510/8530
Operating Temperature−10°C to +50°C
Operating Humidity5–95% RH (non-condensing)
Storage Temperature−30°C to +60°C
Storage Humidity0–95% RH (non-condensing)
Supply VoltageDC 5.0 V ±0.1 V, ripple <50 mV
Operating Current≤100 mA
Standby Current<20 mA
Output InterfacesUART TTL (3.3 V logic), PWM (default 5 V, 3.3 V configurable)
Dimensions58.7 mm (W) × 45 mm (H) × 13.9 mm (D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelPM3006S
Measurement PrincipleLaser Light Scattering
Safety RatingNon-Explosive
Measurement Range0–1000 µg/m³ (detection limit: 30 mg/m³)
Resolution1 µg/m³
Accuracy±10 µg/m³ or ±10% (PM1.0/PM2.5), ±15 µg/m³ or ±15% (PM10), ±20 µg/m³ or ±20% (TSP)
Operating Temperature−40 °C to +70 °C
Relative Humidity0–95% RH (non-condensing)
Power SupplyDC 5.0 V ±0.1 V, ripple <50 mV
Current Consumption≤250 mA (operational), <20 mA (standby)
Output InterfacesUART TTL (3.3 V / 5 V), I²C (3.3 V / 5 V)
Dimensions85 × 74 × 24.9 mm (W × H × D)
Warm-up Time≤8 s
Data Refresh Rate1 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelOPM-6303M
Measurement PrincipleOptical Light Scattering
Safety RatingNon-Explosion-Proof
Measurement Range0–30 mg/m³
PM₁.₀/PM₂.₅ Accuracy±10 µg/m³ (≤100 µg/m³), ±10% of reading (100–1000 µg/m³)
PM₁₀ Accuracy±15 µg/m³ (≤100 µg/m³), ±15% of reading (100–1000 µg/m³)
TSP Accuracy±20 µg/m³ (≤100 µg/m³), ±20% of reading (100–1000 µg/m³)
Warm-up Time≤8 s
Data Update Interval1 s
Operating Temperature−30 to +70 °C
Relative Humidity0–95% RH (non-condensing)
Storage Temperature−40 to +85 °C
Power SupplyDC 12 V
Average Current Draw≤4.5 A
Communication InterfaceRS485
Sampling Flow Rate1 L/min (standard, customizable)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0