- All
- Favorite
- Popular
- Most rated
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1009 |
| Detection Principles | Laser Light Scattering (PM), Metal Oxide Semiconductor (VOC, NOₓ, CO, HC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| NO₂ Range | 0–10 ppm |
| PM Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) for PM₁.₀/PM₂.₅ |
| Data Update Interval | 1 s |
| Power-On Stabilization Time | ≤180 s (VOC channel) |
| Operating Temp. | −10 to +60 °C |
| Operating RH | 5–95% RH (non-condensing) |
| Storage Temp./RH | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V, ripple <50 mV |
| Interfaces | UART (3.3 V / 5 V logic), I²C (5 V logic) |
| Dimensions | 50 × 38 × 21 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1008 |
| Price | USD 72 (FOB) |
| PM2.5 Range | 0–1000 µg/m³ |
| CO₂ Range | 400–5000 ppm |
| VOC Scale | 0–3 (Relative Index) |
| Update Interval | 1 s |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Supply Voltage | DC 5 V ±0.1 V |
| Current Consumption | <300 mA |
| Communication Interfaces | UART-TTL, I²C |
| Dimensions | 80 × 50 × 13.6 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PM2008 |
| Pricing | Available Upon Request |
| Detection Principle | Laser Light Scattering |
| PM2.5 Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±10 µg/m³ or ±10% of reading (at 25°C ±2°C, 50% RH ±10%, calibrated against TSI AM510/8530 reference instrument) |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −20°C to +60°C |
| Housing Material | Full Metal Enclosure (EMI-Shielded) |
| Dimensions (PM2008) | 47.8 mm (W) × 36.8 mm (H) × 11.7 mm (D) |
| Airflow Configuration | Co-planar inlet/outlet on wide face (PM2008/PM2008M) |
| Output Interfaces | UART, PWM, I²C |
| Thickness | ≤12.1 mm |
| Particle Recognition | Intelligent Source Discrimination Algorithm (Cubic Proprietary) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1002 |
| Detection Principle | Laser Scattering (PM) / Metal Oxide Semiconductor (VOC) |
| PM Range | 0–5000 µg/m³ |
| VOC Range | 0–10 ppm |
| PM1.0/PM2.5 Accuracy | ±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) |
| PM10 Accuracy | ±25 µg/m³ (0–100 µg/m³), ±25% reading (101–500 µg/m³) |
| VOC Accuracy | ±15% (@0.3–1 ppm), ±25% (@30 ppm) |
| Warm-up Time | ≤180 s (VOC) |
| Data Refresh Rate | 1 Hz |
| Operating Temp. | −20–60 °C |
| Operating RH | 0–95% RH (non-condensing) |
| Storage Temp./RH | −40–80 °C / 0–95% RH |
| Supply Voltage | DC 5 V ±0.5 V (ripple <50 mV) |
| Interfaces | UART (3.3 V/5 V), I²C (3.3 V/5 V) |
| Dimensions | 38 × 35 × 12 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-2105 |
| Price | Upon Request |
| Measurement Principle | Microflow Non-Dispersive Infrared (NDIR) with Dual-Chamber (Sample + Reference) Architecture |
| Target Gases | CO, NO, SO₂, CO₂, CH₄ |
| Moisture Compensation | Integrated Humidity Compensation Module |
| Temperature & Pressure Compensation | Automatic Real-Time Compensation |
| Heating Control | Thermostatically Controlled Gas Cell |
| Linearity Error | ±2% FS |
| Repeatability | ±2% FS |
| Zero/Full-Scale Drift | <2.5% FS per 7 days |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2060 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | SiF₄, CF₄, SF₆, NF₃, CO₂ |
| Range | 1–264 ppm (0–200 mTorr) |
| Repeatability | ±0.5% |
| Linearity | ±1% F.S. |
| Detection Limit | 1 ppm |
| Output | Analog (4–20 mA) & Digital (RS485/Modbus RTU) |
| Design | Modular, Flange-Mountable (CF/KF compatible), Protocol-Ready for OEM Integration |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2102 |
| Price | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Microflow Dual-Chamber Detection |
| Target Gas | Nitric Oxide (NO) |
| Range | 0–200 / 0–2000 / 0–5000 ppm (customizable) |
| Resolution | 1 ppm |
| Accuracy | ±25 ppm or ±4% of reading (whichever is greater) |
| Repeatability | ±20 ppm or ±3% of reading (whichever is greater) |
| Response Time (T90) | ≤4.5 s |
| Temperature & Pressure Compensation | Automatic |
| Brand | Cubic |
|---|---|
| Model | ATRS-1010-P |
| Detection Principle | MEMS-based Absolute Pressure Sensing |
| Measurement Range | 50–160 kPa |
| Full-Scale Peak Load | 600 kPa |
| Burst Pressure | 800 kPa |
| Resolution | 0.1 kPa |
| Accuracy | ≤ ±1.15 kPa (0–85 °C), ≤ ±1.725 kPa (−40–0 °C & 85–125 °C) |
| Response Time | <1 s (pressure anomaly detection & wake-up signal to BMS), <50 ms (first CAN frame after BMS wake-up) |
| Output Interface | CAN 2.0B, 500 kbps |
| Sampling Interval | 10 ms (normal mode), 1 s (low-power mode) |
| Power Supply | 9–16 VDC (nominal 12 VDC) |
| Operating Current | 20 mA (normal), <0.2 mA (low-power), <100 µA (sleep) |
| Operating Temperature | −40 to +105 °C |
| Storage Temperature | −40 to +125 °C |
| Humidity Range | 0–99% RH (non-condensing) |
| Enclosure Material | UL94 V-0 flame-retardant polymer |
| Ingress Protection | IP40 |
| Design Lifetime | >15 years |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | SF6+O2 |
| Detection Principle | NDIR for SF6 |
| SF6 Range | 0–1500 ppm |
| O₂ Range | 0–25.0 %vol |
| SF6 Resolution | 1 ppm |
| O₂ Resolution | 0.1 %vol |
| SF6 Accuracy | ±2% FS |
| O₂ Accuracy | ±0.5% vol |
| SF6 Alarm Threshold | Adjustable (default 1000 ppm) |
| O₂ Alarm Threshold | Adjustable (default 18.0% vol) |
| Response Time (T90) | ≤60 s (diffusion mode) for both gases |
| Temperature Range | −30 to +85 °C |
| Temp Accuracy | ±1 °C |
| Humidity Range | 0–99 %RH |
| RH Accuracy | ±5 %RH |
| PIR Detection Distance | ≥3 m |
| Dimensions | 205 × 105 × 58 mm |
| Weight | <1.5 kg |
| Output Interfaces | RS485, Wi-Fi, optional RS232 |
| IP Rating | IP54 (customizable) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1% |
| Power Consumption | <15 W |
| Design Life | >10 years |
| Compliance | DL/T 1555–2016, DL/T 639, JB/T 10893 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2063 |
| Pricing | Available Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2200 |
| Price | Upon Request |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Target Gases | SO₂, NO, NO₂ |
| SO₂/NO Range | 0–100 / 0–2000 ppm (configurable) |
| NO₂ Range | 0–500 / 0–5000 ppm (configurable) |
| Linearity Error | ±2% F.S. |
| Repeatability | ±2% F.S. |
| Zero/Full-Scale Drift | <2.5% F.S. per 7 days |
| Light Source | Pulsed Xenon Lamp |
| Compensation | Automatic Temperature & Pressure Compensation |
| Output Interface | Analog (4–20 mA) and Digital (RS485/Modbus RTU) |
| Module Form Factor | OEM-integrated sensor unit |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AAG-1000 |
| Negative Ion Output | ≥ 3 × 10⁶ pcs/cm³ |
| Residual Ozone Concentration | ≤ 0.05 ppm |
| Operating Voltage | 21–27 V DC |
| Operating Current | ≤ 30 mA |
| Output High Voltage | –3.5 ± 0.5 kV (1 G) |
| Protection Impedance | 20 ± 2 MΩ |
| Dielectric Withstand Voltage | ≥ 3750 V AC |
| Dimensions | 67.8 × 44.9 × 22 mm (W × H × D) |
| EMC Compliance | ISO 11452-4 & ISO 16750-2 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM1050 |
| Detection Range | ≥0.3 µm, 0–9,999,999 pcs/L |
| Output Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Counting Efficiency | 50% @ 0.3 µm |
| Operating Temperature | −30°C to +70°C |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5 V ±0.1 V or DC 9–36 V |
| Current Draw | <500 mA @ 5 V, <300 mA @ 9 V, <100 mA @ 36 V |
| Communication Interface | RS-485 / 4–20 mA (customizable) |
| Dimensions | 100 × 115 × 40 mm (W × D × H) |
| Compliance | JJF 1190–2008 Calibration Specification for Airborne Particle Counters |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ACDS-1001 |
| Detection Principle | Dual-channel NDIR (Non-Dispersive Infrared) |
| Gas Measured | CO₂ |
| Measurement Range | 0–10,000 ppm (extended capability up to 40,000 ppm) |
| Resolution | 1 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Response Time (T90) | ≤25 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | LIN bus |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +95 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| IP Rating | IP54 |
| Supply Voltage | 9–16 VDC (nominal 12 VDC) |
| Average Current Consumption | ≤100 mA @ 12 VDC |
| Standby Current | <100 µA |
| Design Lifetime | 15 years |
| Compliance | AEC-Q200 qualified circuit architecture, automotive-grade EMI/EMC robustness |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-7500K-OAQ |
| Detection Principle | Ultrasonic Transit-Time Method |
| Flow Range | 0–20 L/min |
| Accuracy | ±3% FS or ±0.2 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20 °C to +60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (5 V logic) |
| Dimensions | 120 × 30 × 22 mm (W × H × D) |
| Certifications | CMC, CE, EMC compliant |
| Zero Drift | Negligible (factory-compensated) |
| Calibration | Factory-calibrated |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SF6+O2-CAB-7IN |
| Price | Upon Request |
| Display | 7-inch resistive touchscreen (800×480) |
| Alarm Triggers | SF6 ≥ 1000 ppm, O₂ ≤ 19.6% vol |
| Communication | RS485 (≤1000 m), Wi-Fi |
| PIR Detection Range | ≥3 m |
| Relay Output Capacity | 250 VAC / 10 A |
| Data Retention | 10 years (non-volatile memory) |
| Enclosure Rating | IP54 (customizable) |
| Operating Temp. | –20°C to +50°C |
| Humidity Range | 0–90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1%, <15 W |
| Compliance | DL/T 1555–2016, DL/T 639, JB/T 10893 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | PM3003SN |
| Detection Principle | Laser Light Scattering |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Counting Range | 0–10,000,000 pcs/L (equivalent to 0–283,000,000 pcs/ft³) |
| Counting Efficiency | 50% at 0.3 µm |
| Warm-up Time | ≤8 s |
| Data Update Interval | 1 s |
| Operating Temperature | −30°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −40°C to +85°C |
| Supply Voltage | DC 5.0 V ±0.1 V (ripple <50 mV) |
| Operating Current | <150 mA |
| Standby Current | <25 mA |
| Communication Interfaces | UART-TTL (3.3 V / 5 V), I²C (3.3 V / 5 V), RS-485 |
| Dimensions | 82 × 40.2 × 26.3 mm (W × H × D) |
| Compliance | JJF 1190–2008 (Calibration Specification for Airborne Particle Counters) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APMS-3302 |
| Price | USD 78 (FOB) |
| Detection Principle | Laser Scattering (Mie Theory) |
| PM2.5 Range | 0–1000 µg/m³ |
| Accuracy | ±15% of reading or ±15 µg/m³ (at –20°C to +60°C, referenced to TSI AM510/8530) |
| Operating Temperature | –30°C to +70°C |
| Storage Temperature | –40°C to +85°C |
| Ingress Protection | IP5K4 |
| Supply Voltage | DC 9–16 V |
| Communication Interface | LIN 2.2A |
| Output Options | PM2.5 mass concentration (µg/m³) |
| Response Time | <3 s (dynamic airflow, vehicle motion conditions) |
| Laser Source Lifetime | >50,000 hours |
| Optical Chamber | Self-cleaning lens structure with hydrophobic coating |
| Calibration Traceability | NIST-traceable reference aerosols (ISO 2591-1, ISO 12103-1 A2 test dust) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2501-05F |
| Detection Gas | CH₄ |
| Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Range | 0–100% LEL |
| Accuracy | ±5% LEL |
| Resolution | 0.1% LEL |
| Response Time (T90) | <20 s |
| Operating Temperature | −25 °C to +55 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Storage | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Supply Voltage | 3.2 V–5.5 V |
| Output Interface | TTL (3.0 V logic level) |
| Current Consumption | 15 mA |
| Lifetime | ≥10 years |
| Selectivity | Methane-specific, immune to interference from H₂O vapor, CO₂, CO, H₂, hydrocarbons, and particulates |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM1009CN |
| Detection Principles | Optical Scattering (PM2.5), Electrochemical/Semiconductor (CO), NTC Thermistor (Temperature) |
| Measurement Ranges | PM2.5: 0–5000 µg/m³ |
| CO | 0–1000 ppm |
| Temperature | −10–60 °C |
| Accuracy | PM2.5: ±20% of reading or ±200 µg/m³ |
| CO | ±30% of reading or ±40 ppm |
| Temperature | ±1 °C |
| Alarm Thresholds | PM2.5 ≥ 2000 µg/m³ |
| Data Update Interval | 1 s |
| Operating Conditions | −10–60 °C, 0–95% RH (non-condensing) |
| Storage Conditions | −30–70 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ± 0.5 V, Ripple < 100 mV |
| Average Current Consumption | < 100 mA |
| Output Interface | Digital Switch Output (configurable for CAN bus upon request) |
| Dimensions | 100 × 60 × 24.5 mm (W × H × D) |
| Minimum Detectable Particle Size | 0.3 µm |
| Sampling Method | Constant-Flow Aspiration |
| Calibration | Auto-compensated CO baseline correction |
| Compliance | RoHS-compliant design |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2000 |
| Pricing | Available Upon Request |
| Measurement Principle | Dual-beam NDIR (Non-Dispersive Infrared) Spectroscopy |
| Measured Gases | CO, CO₂, HC (hydrocarbons), optional O₂ and NO |
| HC Range | (0–2000)×10⁻⁶ (ppm), CO: (0.00–10.00)×10⁻² (% vol), CO₂: (0.0–16.0)×10⁻² (% vol), NO (optional): (0–4000)×10⁻⁶ (ppm), O₂ (optional): (0.0–25.0)×10⁻² (% vol) |
| Accuracy | Complies with GB 18285–2018, ISO 3930, OIML R99 |
| Resolution | HC/NO: 1 ppm |
| CO/CO₂/O₂ | 0.001%/0.01%/0.01% vol |
| Response Time (T₉₀) | ≤4.5 s (NDIR) |
| Output Interface | RS-232 |
| Operating Voltage | 12 V ±0.2 V, 3.2 A |
| Environmental Compensation | Automatic temperature & pressure correction |
| Design | Modular sensor architecture, heated optical path |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4207 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–50% LFL |
| Accuracy | ±5% LFL |
| Response Time (T50) | ≤10 s |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Humidity Range | 0–100% RH |
| Supply Voltage | DC 9–36 V |
| Current Consumption | <250 mA |
| Communication Interface | CAN bus |
| Protection Rating | IP67 (detector housing), IP65 (sensor head) |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2502 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–1000 ppm |
| Accuracy | ±5 ppm + 2% of reading |
| Resolution | 0.1 ppm |
| Warm-up Time | <10 s |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| Supply Voltage | 3.2–5.5 V DC |
| Current Consumption | <100 mA (@25 °C, 3.3 V) |
| Output Interface | TTL (3.3 V logic level) |
| Dimensions | 278 × 97 × 84 mm |
| Storage Conditions | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Selectivity | High (inherent spectral specificity of TDLAS) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-8500Z |
| Detection Principle | Zirconia Electrochemical |
| Measurement Range | 0.1–25.0 vol.% O₂ |
| Accuracy | ±2% FS |
| Resolution | 0.01% O₂ |
| Response Time | <1 s |
| Operating Temperature | 10–50 °C |
| Operating Humidity | 5–85% RH (non-condensing) |
| Storage Conditions | −20–60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ±0.5 V |
| Output Interface | UART TTL (3.3 V logic level) |
| Dimensions | 70 × 40 × 15.3 mm (W×H×D) |
| Surface Temperature Limit | <150 °C (internal sensor element up to <350 °C) |
| Inlet Flow Mode | Free Diffusion |
| Cross-Sensitivity | Negligible (zirconia-selective for O₂) |
Show next