BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard 3500
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesO₂, CO, CO₂, H₂S, CH₄
Explosion Protection RatingEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Response Time<40 s
Sample Flow Rate0.7–1.2 L/min
Output SignalsRS-485 / RS-232 / 4–20 mA
DisplayLCD
Power SupplyAC 220 V, 50 Hz
Auto-Zero FunctionIntegrated air pump for in-situ zero calibration
Diagnostic CapabilityReal-time sensor health monitoring
PreconditioningIntegrated front-end sample conditioning for wet, dusty, and oily gas streams
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
ModelGasboard 3500
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesO₂, CO, CO₂, H₂S, CH₄
Accuracy±0.5–2% F.S. (gas- and range-dependent)
Resolution0.01% vol to 1 ppm
Response Time<40 s
Sample Flow Rate0.7–1.2 L/min
Explosion ProtectionEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Output InterfacesRS-485, RS-232, 4–20 mA
Power SupplyAC 220 V, 50 Hz
DisplayLCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
ModelGasboard-3500
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesO₂, CO, CO₂, H₂S, CH₄
Detection RangesO₂ (0–100% vol, down to 1 ppm), CO (0–100% vol, down to 0.1 ppm), CO₂ (0–100% vol, down to 0.1 ppm), H₂S (0–1% vol, down to 0.1 ppm), CH₄ (0–100% vol, down to 0.1 ppm)
Accuracy±0.5–2% F.S. depending on gas and range
Response Time<40 s (at 2 L/min)
Sample Flow Rate0.7–1.2 L/min (optimal), up to 2 L/min
Explosion ProtectionEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Output InterfacesRS-485, RS-232, 4–20 mA analog
Power SupplyAC 220 V, 50 Hz
DisplayIntegrated LCD
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: CUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
Explosion Protection RatingEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesO₂, CO, CO₂, H₂S, CH₄
Response Time<40 s (at 2 L/min)
Sample Flow Rate0.7–1.2 L/min (optimal), up to 2 L/min
Output InterfacesRS-485, RS-232, 4–20 mA
Power SupplyAC 220 V, 50 Hz
DisplayIntegrated LCD
Built-in ZeroingAir auto-zero pump
Diagnostic CapabilityReal-time sensor self-diagnosis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelCUBIC-LGA-EX
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesO₂, CO, CO₂, H₂S, CH₄
Explosion Protection RatingEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Response Time<40 s (at 2 L/min)
Sample Flow Rate0.7–1.2 L/min (max 2 L/min)
Accuracy±0.5–2% FS depending on gas and range
Resolution0.01% vol / 0.1 ppm / 1 ppm (gas- and range-dependent)
Output Signals4–20 mA, RS-232, RS-485
DisplayIntegrated LCD
Power SupplyAC 220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLMS-1000
PricingUpon Request
Measurement PrincipleTDLAS
MeasurandH₂O vapor
Range0–50 ppm to 0–6000 ppm (customizable)
Accuracy±2% FS
Resolution0.1 ppm
Repeatability≤1.5% FS
Explosion ProtectionEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Ingress ProtectionIP66
Ambient Temperature−10°C to +50°C
Relative Humidity0–98% RH (non-condensing)
Sample PressureInlet: 140–310 kPa
Measurement Cell800–1200 mbar(a)
Power Supply24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W
Output Interfaces4–20 mA, RS-485, Modbus RTU/TCP, Ethernet
Display OptionsVolume ratio (ppm(v)) and dew point temperature (°C/°F)
Dimensions (L×W×H)400 × 400 × 250 mm
Weight36 kg