Empowering Scientific Discovery

Sinfon Optoelectronics (Wuhan) Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100-CH4
Instrument TypeIn-situ Online Analyzer
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesCH₄, O₂, CO, CO₂, H₂S
CH₄ Range0–20 %VOL
O₂ Range0–5 %VOL (customizable to 0–100 %VOL)
CO Range0–100 %VOL
CO₂ Range0–100 %VOL
H₂S Range0–100 ppm / 0–5000 ppm
Accuracy≤ ±1 %FS
Repeatability≤ ±1 %FS
Zero/ Span Drift≤ ±1 %FS/7d
Resolution0.01 %VOL (CH₄)
Response Time (T90)≤ 4 s
Ambient Temp.−20 to +60 °C
Power Supply24 V DC, 24 W
Enclosure RatingExd II CT6
Output2 × 4–20 mA, 3 × Relay
CommunicationRS485, RS232
Purge GasIndustrial N₂, 0.3–0.8 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-2502
Instrument TypeOnline
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Target AnalyteCH₄
Measurement Range0–1000 ppm
Resolution0.1 ppm
Accuracy±(5 ppm + 2% of reading)
Warm-up Time<10 s
Operating Temperature−20 °C to +60 °C
Relative Humidity0–98% RH (non-condensing)
Operating Pressure80–120 kPa
Supply Voltage3.2–5.5 VDC
Current Consumption<100 mA (@25 °C, 3.3 V)
Communication InterfaceTTL (3.3 V logic level)
Dimensions (L×W×H)278 × 97 × 84 mm
Storage Conditions−40 °C to +85 °C, 0–98% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable
Measured SpeciesCH₄, C₂H₆
Optical Path ConfigurationSealed Absorption Cell
Detection Limit (CH₄)<100 ppb
Detection Limit (C₂H₆)<15 ppb
Data Acquisition Rate10–20 Hz
Included AccessoriesGNSS Positioning System (BeiDou-compatible), Ultrasonic Anemometer
Compliance ContextDesigned for field-deployable ambient air monitoring per EPA Method 21 principles and ISO 13864:2022 guidance on mobile gas leak detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable UAV-Mounted Gas Analyzer
Detection PrincipleMid-Infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Target AnalyteCH₄
Measurement RangeNot specified (CH₄-specific)
Detection Limit<100 ppb (CH₄), <15 ppb (C₂H₆)
Optical PathOpen-Path
Data Acquisition Rate10–20 Hz
Sensitivity<100 ppb (CH₄)
Weight<3 kg
Software FeaturesLeak event identification & quantification, deep learning–enabled pattern recognition
Enclosure MaterialCorrosion-Resistant Alloy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3000GHG
Instrument TypeOnline Analyzer
Detection PrincipleMicro-flow NDIR & Dual-beam NDIR (CO₂/CH₄/N₂O/CO), Electrochemical (O₂)
Measured GasesCO₂, CH₄, N₂O, CO, O₂
CH₄ Range0–1000 ppm, Resolution: 1 ppm
Repeatability≤ ±1% F.S.
Accuracy±1% F.S. (micro-flow NDIR), ±2% F.S. (dual-beam NDIR & ECD)
Response Time (T90)< 25 s
Sample Flow Rate0.7–1.2 L/min
Inlet Pressure2–50 kPa
Power Supply100–240 VAC, max 300 W (heating), stable 100 W
OutputRS-485/RS-232, 4–20 mA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Target AnalyteCH₄
Measurement Range0–1000 ppm
Detection Limit1 ppm
Alarm Accuracy±(5 ppm + 2% of reading)
Resolution1 ppm
Response Time (T90)<10 s
Measurement Cycle30 s
Data Upload Interval2 min
CommunicationLoRaWAN / NB-IoT
IP RatingIP66
Operating Temperature−20 °C to +60 °C
Operating Humidity0–95% RH (non-condensing)
Operating Pressure86–106 kPa
Power SupplyRechargeable Li-ion battery + optional solar panel
Max. Power Consumption2 W
Dimensions (L×W×H)186 mm × 144 mm × 417 mm
Weight6.5 kg
Service Life≥10 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable
ModelCH4
Resolution320 × 256
Spectral Band3.2–3.5 µm
Temperature Range−20 to 350 °C
Temperature Accuracy±1 °C (0–100 °C), ±2 °C (−20–0 °C), ±2% of reading (>100 °C)
Ingress ProtectionIP54
Explosion ProtectionEx ic nc op is IIC T4 Gc
Storage64 GB SD card
ConnectivityUSB, HDMI, SD card slot, Wi-Fi
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasCH₄
Measurement Range0–1000 ppm
Detection Limit1 ppm
Alarm Accuracy±(5 ppm + 2% of reading)
Resolution1 ppm
Response Time (T90)<10 s
Measurement Cycle30 s
Data Upload Interval2 min
CommunicationLoRaWAN / NB-IoT
IP RatingIP66
Operating Temperature−20 °C to +60 °C
Operating Humidity0–95% RH (non-condensing)
Operating Pressure86–106 kPa
Power SupplyRechargeable Li-ion battery + optional solar panel
Max. Power Consumption2 W
Dimensions (L×W×H)186 mm × 144 mm × 417 mm
Weight6.5 kg
Service Life≥10 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypePortable
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured SpeciesCH₄
Methane Concentration Range0.01%–100% vol
Emission Flux Range0.01–13 kg/h
Measurement Accuracy±5% of reading
Sampling Flow Rateup to 400 L/min
Battery Runtime>8 h
Charging Time10 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Instrument TypeOnline
Detection PrincipleNDIR (CO, CO₂, CH₄, C₃H₈), Electrochemical (O₂, H₂S)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement RangeCO/CO₂/CH₄/C₃H₈: (0–100)% vol
O₂(0–25)% vol
H₂S(0–9999) ppm
Repeatability≤2%
Accuracy±1% FS (NDIR gases), ±2% FS (O₂/H₂S)
Response Time (T90)<15 s (NDIR)
Flow Rate0.7–1.2 L/min
Inlet Pressure2–50 kPa
DisplayLCD
OutputRS-485/RS-232, 4–20 mA, Ethernet
PowerAC 220 V, 50 Hz
Explosion ProtectionEx d II CT6 / Ex tb IIIC T80°C Db
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0