Empowering Scientific Discovery

Sinfon Optoelectronics (Wuhan) Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9085
PrincipleUV-DOAS / NDIR / ECD / CIDR
TypeOnline Continuous Emission Monitoring System (CEMS)
Measurement RangeSO₂: 0–500 ppm
NO0–1000 ppm
CO0–10000 ppm
CO₂0–25% vol
HC0–10000 ppm
O₂0–25% vol
Response Time≤30 s
Accuracy±2% F.S.
Zero/Full-Scale Drift≤2% F.S./24 h
RepeatabilitySO₂, CO₂, CH₄, N₂O, HC, O₂
Sample Flow Rate6 L/min
Dew Point Output≤5 °C
Filtration5 µm → 0.1 µm dual-stage particulate filtration
ComplianceMARPOL Annex VI, GB 15097–2016, GD01–2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Detection PrincipleNDIR & Electrochemical (ECD)
ConfigurationFixed-mount online analyzer
Response TimeT90 < 15 s (NDIR channels)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Explosion Protection RatingEx d IIC T6 / Ex tb IIIC T80°C Db
Measurement RangesCO/CO₂/CH₄/C₃H₈: 0–100% vol
O₂0–25% vol
H₂S0–9999 ppm
Accuracy±1% FS (NDIR gases), ±2% FS (O₂ & H₂S)
Repeatability≤2%
Resolution0.01% vol (low-range: 1 ppm for H₂S)
Sample Flow Rate0.7–1.2 L/min
Inlet Pressure2–50 kPa
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayBacklit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Measurement PrincipleNDIR & Electrochemical Detection
ConfigurationOnline Fixed Installation
Response TimeT90 < 15 s (NDIR)
Repeatability≤2% FS
Accuracy±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S)
Resolution0.01% vol (low-range: 1 ppm)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
Output InterfacesRS-485 / RS-232 / 4–20 mA / Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD
Explosion ProtectionEx d IIC T6 Gb / Ex tb IIIC T80°C Db
Sample ConditioningIntegrated front-end pretreatment (particulate filtration, moisture removal, oil rejection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9081
Measurement PrincipleUV-DOAS (NOx, SO₂), NDIR (CO, CO₂), Electrochemical (O₂)
ConfigurationOnline Multicomponent Gas Analyzer
Detection RangeNOx/SO₂: 0–100 mg/m³
O₂/CO₂0–25% vol
CO0–5% vol
Response Time≤30 s
Repeatability±1% FS (NO, SO₂, O₂)
ResolutionNOx/SO₂/CO: 1 mg/m³
O₂/CO₂/CO0.01% vol
Zero DriftNOx/SO₂: ≤1% FS/24 h
CO/CO₂/O₂≤2% FS/24 h
Accuracy±2% FS (all measured components)
Power Supply220 V AC ±20%, 50 Hz ±1 Hz
Display7-inch capacitive touchscreen
Communication InterfacesRS232, RS485, 4–20 mA analog output, audible/visual alarm relay
Data StorageInternal non-volatile memory supporting ≥3 years of 1-minute interval data
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Measurement PrincipleNDIR & Electrochemical Detection
ConfigurationFixed Online Analyzer
Response TimeT90 < 15 s (NDIR)
Repeatability≤2% FS
Accuracy±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S)
Resolution0.01% vol (low-range: 1 ppm)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
Explosion ProtectionEx d II CT6 / Ex tb IIIC T80°C Db
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD
PreconditioningIntegrated sample conditioning system (particulate filtration, moisture removal, oil exclusion)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500 (Explosion-Proof)
Measurement PrincipleNon-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD)
ConfigurationOnline Fixed-Mount Analyzer
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
RangeCO/CO₂/CH₄/C₃H₈: 0–100% vol
O₂0–25% vol
H₂S0–9999 ppm
Response Time (T₉₀)<15 s (NDIR channels)
Accuracy±1% FS (NDIR gases), ±2% FS (O₂, H₂S)
Repeatability≤2%
Resolution0.01% (low-range equivalent to 1 ppm)
Sample Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
Electrical InterfaceRS-485 / RS-232 / 4–20 mA / Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD
Explosion ProtectionEx d IIC T6 Gb / Ex tb IIIC T80°C Db
CertificationsCompliant with GB 3836.1–2010, GB 3836.2–2010, GB 3836.8–2014
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9031EX
Measurement PrincipleNDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CₙHₘ), TCD (H₂), ECD (O₂)
Detection RangeCO/CO₂/CH₄/H₂: (0–100)% vol
O₂(0–25)% vol
C₂H₂/C₂H₄/CₙHₘ(0–10)% vol (optional)
Accuracy±1% FS (NDIR channels), ±2% FS (TCD & ECD channels)
Repeatability≤±0.5% FS
Explosion Protection RatingEx d IIC T4 Gb
Output InterfacesRS-232, RS-485, (4–20) mA, Ethernet
DisplayLCD
Auto-CalibrationBuilt-in zero-air pump with automatic air zeroing
Diagnostic FunctionReal-time sensor health monitoring
Sample HandlingHeated stainless steel probe, dual-stage filtration, single-stage refrigerative dryer, pulsed back-purge
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Instrument TypeOnline Analyzer
Measurement PrincipleZirconia Limiting-Current Electrochemistry + Thick-Film Catalytic Oxidation
Detection RangeO₂: 0–25% vol
COe0–10,000 ppm
Response TimeO₂: T₉₀ ≤ 10 s
COeT₉₀ ≤ 20 s
AccuracyO₂: ±1% FS or ±0.2% vol
COe±5% FS or ±25 ppm
ResolutionO₂: 0.01% vol
COe1 ppm
CommunicationRS-485 / MODBUS RTU
Analog Outputs2 × 4–20 mA
Alarm Outputs3 configurable relay outputs
Environmental Operating RangeControl Unit: −40°C to +65°C
Sensor Unit−40°C to +120°C
IP RatingIP66
Probe MaterialsS316L stainless steel, Alloy 600, Alumina (Al₂O₃)
Flange MountingDN50 (customizable)
Probe LengthCustomizable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9082 (Standard Edition)
PrincipleElectrochemical Detection (NO, O2, CO) & Non-Dispersive Infrared (NDIR) for CO₂
TypeOnline Fixed-Mount Analyzer
Measurement RangeNO: 0–100 mg/m³
O₂ & CO₂0–25% vol
CO0–5% vol
Response Time≤30 s
Repeatability±2% FS (NO, O₂, CO, CO₂)
Accuracy≤±3% FS
Power Supply220 V AC ±20%, 50 Hz ±1 Hz
Output InterfacesRS232, RS485, 4–20 mA analog output, audible/visual alarm relay
Data StorageInternal flash memory supporting ≥3 years of minute-interval historical data
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3000F
TypeOnline Analyzer
Measurement PrincipleUV-Differential Optical Absorption Spectroscopy (UV-DOAS) & Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Response Time60 sec @ T90
Repeatability≤1% FS
H₂S Range0–100 ppm
SO₂ Range0–100 ppm
CO Range0–500 ppm
SF₆ Range0–100% vol
Dew Point Range−60 to +20 °C
ResolutionH₂S/SO₂/CO: 0.1 ppm
SF₆0.01% vol
Dew Point0.1 °C
Linearity Error±1% FS
Zero Drift±2% FS / 4 h
Span Drift±2% FS / 4 h
Warm-up Time45 min
Power SupplyInternal Li-ion Battery (4 h runtime)
Power Consumption<100 W
Operating Temp.5–40 °C
RH≤95% RH
Pressure70–106 kPa
CommunicationUSB, RS-232, RS-485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3001
ConfigurationOnline Multicomponent Gas Analyzer
Measurement PrinciplesNDIR (CO₂), TDLAS (CH₄, N₂O)
CO₂ Range0–1000 ppm
CH₄ Range0–50 ppm
N₂O Range0–20 ppm
Accuracy±1% of full scale for all gases
Repeatability<1% RSD for CO₂, CH₄, and N₂O
Power SupplyInternal rechargeable battery ≥8 h continuous operation
Data StorageOnboard memory supporting ≥3 months of timestamped concentration data
Communication InterfacesRS-232, RS-485, USB, optional Ethernet/Wi-Fi module
Enclosure RatingIP65
Operating Temperature–10 °C to +50 °C
Dimensions280 × 190 × 120 mm
Weight≤3.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9021EX
Measurement PrincipleNDIR (CO, CO₂, CH₄, C₂H₂, C₂H₄, CnHm), TCD (H₂), ECD (O₂)
Detection RangeCO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm: (0–10)% (optional)
Accuracy±1% FS (NDIR channels), ±2% FS (H₂/O₂)
Repeatability≤1% FS
Explosion Protection RatingEx d II C T4 Gb
Display10-inch capacitive touchscreen LCD
Output InterfacesRS-232, RS-485, (4–20) mA analog, Ethernet
Auto-calibrationBuilt-in zero-air pump with automated air zeroing
Diagnostic CapabilityReal-time sensor health monitoring and system self-diagnosis
Sample ConditioningIntegrated dual-stage filtration, steam-jacketed or straight-tube probe (user-selectable), single-stage refrigerative dryer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3100
Detection PrincipleNon-Dispersive Infrared (NDIR), Electrochemical (ECD), Thermal Conductivity (TCD)
ConfigurationOnline Fixed-Mount Analyzer
Measured GasesCO, CO₂, CH₄, H₂, O₂, C₂H₂, C₂H₄, CnHm (total non-methane hydrocarbons), Calorific Value
RangeCO/CO₂/CH₄/H₂: (0–100) % vol
O₂(0–25) % vol
C₂H₂/C₂H₄/CnHm(0–10) % vol (optional)
Linearity Error±1 % FS (NDIR channels)
Resolution0.01 % vol
Repeatability≤1 %
Response Time (T90)<15 s (NDIR)
Sample Flow Rate(0.7–1.2) L/min
Inlet Pressure(2–50) kPa
Power Supply100–240 VAC, 100 W
OutputRS-485 / RS-232, (4–20) mA
DisplayLCD with local interface
CalibrationBuilt-in zero-air pump for automatic air zeroing
Thermal Value Unitskcal/m³ and MJ/m³ (switchable)
Materials of Construction316L stainless steel, PTFE-wetted components
ComplianceDesigned for continuous emission monitoring (CEM) and process control in industrial environments per ISO 14001-aligned operational practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Installation TypeIn-situ transmittance (line-of-sight)
Measured GasesH₂S, O₂, CO, CO₂, CH₄
O₂ Range0–5 %vol (customizable to 0–100 %vol)
Response TimeT90 ≤ 1 s
Repeatability≤ ±1 %FS
Accuracy≤ ±1 %FS
Zero/ Span Drift≤ ±1 %FS per 30 days
Resolution0.01 %vol (O₂), 0.01 ppm (H₂S)
Explosion ProtectionExd II CT6 Gb / Ex tb IIIC T80°C Db
Operating Temperature−20 to +60 °C
Power Supply24 V DC, 24 W
Purge GasIndustrial nitrogen, 0.3–0.8 MPa
Output2 × 4–20 mA, 3 × relay
CommunicationRS485, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3100P
PrincipleNDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂)
TypePortable
Measurement RangeCO/CO₂/CH₄/H₂: (0–100)%
O₂(0–25)%
C₂H₂/C₂H₄/CnHm(0–10)% (optional)
Resolution0.01%
Repeatability≤1% FS
Response Time (T90)<15 s (NDIR)
Linear Error±1% FS (NDIR gases), ±2% FS (O₂/H₂)
Sample Flow Rate(0.7–1.2) L/min
Inlet Pressure(2–50) kPa
Dimensions (L×W×H)412×152×294 mm
Weight9 kg
PowerRechargeable Li-ion battery, external 12.6 V charger
CommunicationRS-232
Thermal Value Unitskcal/m³ & MJ/m³ (switchable)
Self-diagnostic capabilityYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3000F
Instrument PrincipleUV-DOAS + TDLAS + Micro-flow NDIR
TypePortable
Response Time<60 s
Repeatability≤±2% F.S. (decomposition products), ≤±0.5 °C (dew point)
Measurement RangesSO₂: 0–100 ppm, H₂S: 0–100 ppm, CO: 0–1000 ppm, SF₆: 0–100%, Dew Point: −80 to +20 °C
ResolutionSO₂/H₂S: 0.1 ppm, CO: 1 ppm, SF₆: 0.01%, Dew Point: 0.1 °C
Warm-up Time800 s
Zero/End-point Drift±2% F.S./4 h
Operating Temperature5–40 °C
Power SupplyRechargeable Li-ion battery (≥4 h runtime)
Communication InterfaceRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Product TypeOnline Analyzer
ModelGasboard-3500 (Standard)
Measurement PrincipleNon-Dispersive Infrared (NDIR) and Electrochemical Detection (ECD)
Response TimeT90 < 15 s (NDIR)
Repeatability≤1% FS for CO, CO₂, CH₄, C₃H₈
Measurement RangesCO/CO₂/CH₄/C₃H₈: 0–100% vol
O₂0–25% vol
H₂S0–9999 ppm
Accuracy±1% FS (NDIR gases), ±2% FS (O₂/H₂S)
Resolution0.01% vol (low-range equivalent to 1 ppm)
Sample Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
Sample RequirementsDust-free, moisture-free, oil-free
Electrical InterfaceRS-485/RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD with built-in diagnostics and auto-zero function using integrated air pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3002
PrincipleMicro-flow NDIR (Non-Dispersive Infrared) Absorption
TypePortable
Response Time<60 s
Repeatability±2% F.S.
SF₆ Purity Range0–100% vol
Resolution0.01% SF₆
Accuracy±2% F.S.
Zero/End Point Drift±2% F.S. / 4 h
Warm-up Time800 s
Operating Temperature5–40 °C
Power SupplyRechargeable Li-ion Battery (≥4 h runtime)
Communication InterfaceRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500 (Explosion-Proof)
Measurement PrincipleNon-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD)
ConfigurationOnline Fixed-Mount Analyzer
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
RangeCO/CO₂/CH₄/C₃H₈: 0–100% vol
O₂0–25% vol
H₂S0–9999 ppm
Resolution0.01% vol (down to 1 ppm for low-range gases)
Response TimeT₉₀ < 15 s (NDIR channels)
Repeatability≤2% FS
Accuracy±1% FS (CO, CO₂, CH₄, C₃H₈)
Sample Flow Rate0.7–1.2 L/min
Inlet Pressure2–50 kPa
Sample RequirementsDust-free, moisture-free, oil-free
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayIntegrated LCD
Explosion ProtectionEx d IIC T6 Gb / Ex tb IIIC T80°C Db
CertificationsCompliant with GB 3836.1–2010, GB 3836.2–2010, GB 3836.8–2014
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Measurement PrincipleNDIR & Electrochemical Detection
ConfigurationFixed Online Analyzer
Response TimeT90 < 15 s (NDIR)
Repeatability≤2% FS
AccuracyCO/CO₂/CH₄/C₃H₈: ±1% FS
O₂/H₂S±2% FS
Resolution0.01% (low-range: 1 ppm)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Measurement RangesCO/CO₂/CH₄/C₃H₈: (0–100)%
O₂(0–25)%
H₂S(0–9999) ppm
Sample Flow Rate(0.7–1.2) L/min
Inlet Pressure(2–50) kPa
Sample RequirementsDust-free, moisture-free, oil-free
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD
Explosion Protection RatingEx d II CT6 / Ex tb IIIC T80°C Db
Materials in Contact with Sample Gas316L stainless steel, PTFE
Built-in Zero CalibrationAir auto-zero pump
DiagnosticsReal-time sensor health monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3001
PrincipleMicro-flow NDIR + UV-DOAS + TDLAS Hybrid Optical Detection
TypePortable
Response Time<60 s
Repeatability≤±2% F.S. for SO₂, H₂S, CO
Measurement RangesSO₂: 0–100 ppm
H₂S0–100 ppm
CO0–1000 ppm
ResolutionSO₂/H₂S: 0.1 ppm
CO1 ppm
Zero/End Drift±2% F.S./4 h
Warm-up Time800 s
Operating Temperature5–40 °C
Power SupplyRechargeable Li-ion battery (≥4 h runtime)
CommunicationRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3003
PrincipleMicro-flow NDIR (Non-Dispersive Infrared) Absorption
TypePortable
Response Time<60 s
Repeatability±2% F.S.
Operating Temperature5–40 °C
Power SupplyRechargeable Li-ion Battery (≥4 h runtime)
Communication InterfaceRS-232
Preheat Time800 s
Zero/End-point Drift±2% F.S. / 4 h
Resolution0.01% for SF₆ purity (when configured), moisture detection range: 1–1000 ppmv (H₂O in SF₆)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Measurement PrincipleNon-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD)
ConfigurationFixed Online Analyzer
Response TimeT90 < 15 s (NDIR)
Repeatability≤2% FS
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Explosion Protection RatingEx d IIC T6 / Ex tb IIIC T80°C Db
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
Sample Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
DisplayLCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100-CO2
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
ConfigurationIn-situ, dual-beam transmission
Measured GasCO₂ (single-component mode)
O₂ Range(0–5)% vol (customizable up to 100% vol)
CO Range(0–100)% vol
CO₂ Range(0–100)% vol
CH₄ Range(0–20)% vol
Accuracy≤±1% FS
Repeatability≤±1% FS
Zero/Full-Scale Drift≤±1% FS per 30 days
Resolution0.01% vol
Response Time (T90)≤4 s
Operating Temperature−20 to +60 °C
Power Supply24 V DC, 24 W
Explosion ProtectionEx d II CT6
Output Signals2 × 4–20 mA analog outputs, 3 × relay outputs
CommunicationRS485, RS232
Purge GasIndustrial nitrogen, 0.3–0.8 MPa
Show next