Add to compare
BrandCubic
OriginHubei, China
ModelAM1009
Detection PrinciplesLaser Light Scattering (PM), Metal Oxide Semiconductor (VOC, NOₓ, CO, HC)
PM Range0–5000 µg/m³
VOC Range0–10 ppm
NO₂ Range0–10 ppm
PM Accuracy±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³) for PM₁.₀/PM₂.₅
Data Update Interval1 s
Power-On Stabilization Time≤180 s (VOC channel)
Operating Temp.−10 to +60 °C
Operating RH5–95% RH (non-condensing)
Storage Temp./RH−30 to +70 °C / 0–95% RH (non-condensing)
Supply VoltageDC 5 V ±0.1 V, ripple <50 mV
InterfacesUART (3.3 V / 5 V logic), I²C (5 V logic)
Dimensions50 × 38 × 21 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFM01
Detection PrincipleElectrochemical Sensor
Measurement Range0–1 mg/m³
Resolution0.001 mg/m³
Accuracy≤ 0.1 mg/m³: ±0.03 mg/m³
> 0.1 mg/m³±25% of reading
Repeatability< ±3% RSD (typical, per ISO 16000-23)
Response Time (T90)< 60 s
Operating Temperature0–40 °C
Operating Humidity15–95% RH (non-condensing)
Storage Temperature−20–50 °C
Power SupplyDC 5 V ±0.1 V
Current Consumption≤ 300 mA
Communication InterfaceUSB-A
Dimensions101.9 × 26.4 × 16 mm (W × H × D)
ComplianceMeets requirements for indoor air quality screening per ISO 16000-23 and GB/T 18883–2022
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelPM1007
Detection PrincipleOptical Light Scattering (Nephelometry)
Measurement Range0–5 mg/m³
Accuracy±30 µg/m³ or ±30% of reading (at 25±2 °C, 50%±10% RH)
Warm-up Time8 s
Operating Temperature−20 °C to +75 °C
Operating Humidity0–95% RH (non-condensing)
Storage Conditions−40 °C to +85 °C, 0–95% RH (non-condensing)
Supply VoltageDC 5 V ±0.2 V (ripple <100 mV)
Operating Current≤30 mA
Output InterfacesUART (4.5 V logic level), PWM (4.5 V logic level)
Dimensions66.8 × 38.8 × 21.6 mm (W×H×D)
Expected Service Life≥5 years
Electromagnetic ShieldingIntegrated
Particle Size Sensitivity0.3–10 µm
Application DomainCommercial Kitchen Exhaust Monitoring, Fume Hood Compliance Verification, Local Emission Control Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAM1008
PriceUSD 72 (FOB)
PM2.5 Range0–1000 µg/m³
CO₂ Range400–5000 ppm
VOC Scale0–3 (Relative Index)
Update Interval1 s
Operating Temperature−10 °C to +50 °C
Storage Temperature−20 °C to +60 °C
Supply VoltageDC 5 V ±0.1 V
Current Consumption<300 mA
Communication InterfacesUART-TTL, I²C
Dimensions80 × 50 × 13.6 mm (W×H×D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasTDL-3100-CH4
Instrument TypeIn-situ Online Analyzer
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measured GasesCH₄, O₂, CO, CO₂, H₂S
CH₄ Range0–20 %VOL
O₂ Range0–5 %VOL (customizable to 0–100 %VOL)
CO Range0–100 %VOL
CO₂ Range0–100 %VOL
H₂S Range0–100 ppm / 0–5000 ppm
Accuracy≤ ±1 %FS
Repeatability≤ ±1 %FS
Zero/ Span Drift≤ ±1 %FS/7d
Resolution0.01 %VOL (CH₄)
Response Time (T90)≤ 4 s
Ambient Temp.−20 to +60 °C
Power Supply24 V DC, 24 W
Enclosure RatingExd II CT6
Output2 × 4–20 mA, 3 × Relay
CommunicationRS485, RS232
Purge GasIndustrial N₂, 0.3–0.8 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelPM2008
PricingAvailable Upon Request
Detection PrincipleLaser Light Scattering
PM2.5 Measurement Range0–1000 µg/m³
Accuracy±10 µg/m³ or ±10% of reading (at 25°C ±2°C, 50% RH ±10%, calibrated against TSI AM510/8530 reference instrument)
Operating Temperature−10°C to +50°C
Storage Temperature−20°C to +60°C
Housing MaterialFull Metal Enclosure (EMI-Shielded)
Dimensions (PM2008)47.8 mm (W) × 36.8 mm (H) × 11.7 mm (D)
Airflow ConfigurationCo-planar inlet/outlet on wide face (PM2008/PM2008M)
Output InterfacesUART, PWM, I²C
Thickness≤12.1 mm
Particle RecognitionIntelligent Source Discrimination Algorithm (Cubic Proprietary)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-6200
Instrument TypePortable
Measurement PrincipleDiffusion Charging (DC) Method
Measured ComponentExhaust Particulate Number Concentration
Particle Size Range≥23 nm
Accuracy (Indication Error)≤±25%
Zero DriftNot Specified
Span DriftNot Specified
RepeatabilityNot Specified
Response Time<10 s (T₀–T₉₅)
Operating Temperature0–55 °C
Power SupplyAC 100–230 V, 50–60 Hz
Startup Power Consumption700 W
Steady-State Power Consumption200 W
Dimensions (L×H×W)244 × 257 × 419 mm
Weight<10 kg
Data Output InterfaceRS-232 (optional RS-485, Bluetooth, 4G, Wi-Fi)
Heated Sample LineAC-powered (110/230 V), customizable length
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPM3003Q
PriceUSD 630 (FOB)
Operating PrincipleLaser Light Scattering
Safety RatingNon-Explosive Atmosphere Rated
Measurement Range0–50 mg/m³ (max display: 1000 mg/m³)
Accuracy±200 µg/m³ for 0–1 mg/m³
Detection PrincipleOptical Scattering
Recommended Sample Flow Rate2 L/min
Data Update Interval1 s
Operating Temperature30–70 °C
Operating Humidity5–95% RH (non-condensing)
Storage Temperature−40–85 °C
Storage Humidity0–95% RH (non-condensing)
Supply VoltageDC 5 V ± 0.2 V (ripple < 100 mV)
Average Current Consumption<150 mA
Standby Current<25 mA
InterfaceUART (TTL 3.3 V logic level)
Dimensions90.8 × 60.2 × 37.6 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelAM1002
Detection PrincipleLaser Scattering (PM) / Metal Oxide Semiconductor (VOC)
PM Range0–5000 µg/m³
VOC Range0–10 ppm
PM1.0/PM2.5 Accuracy±10 µg/m³ (0–100 µg/m³), ±10% reading (101–500 µg/m³)
PM10 Accuracy±25 µg/m³ (0–100 µg/m³), ±25% reading (101–500 µg/m³)
VOC Accuracy±15% (@0.3–1 ppm), ±25% (@30 ppm)
Warm-up Time≤180 s (VOC)
Data Refresh Rate1 Hz
Operating Temp.−20–60 °C
Operating RH0–95% RH (non-condensing)
Storage Temp./RH−40–80 °C / 0–95% RH
Supply VoltageDC 5 V ±0.5 V (ripple <50 mV)
InterfacesUART (3.3 V/5 V), I²C (3.3 V/5 V)
Dimensions38 × 35 × 12 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9085
PrincipleUV-DOAS / NDIR / ECD / CIDR
TypeOnline Continuous Emission Monitoring System (CEMS)
Measurement RangeSO₂: 0–500 ppm
NO0–1000 ppm
CO0–10000 ppm
CO₂0–25% vol
HC0–10000 ppm
O₂0–25% vol
Response Time≤30 s
Accuracy±2% F.S.
Zero/Full-Scale Drift≤2% F.S./24 h
RepeatabilitySO₂, CO₂, CH₄, N₂O, HC, O₂
Sample Flow Rate6 L/min
Dew Point Output≤5 °C
Filtration5 µm → 0.1 µm dual-stage particulate filtration
ComplianceMARPOL Annex VI, GB 15097–2016, GD01–2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelGasboard-2105
PriceUpon Request
Measurement PrincipleMicroflow Non-Dispersive Infrared (NDIR) with Dual-Chamber (Sample + Reference) Architecture
Target GasesCO, NO, SO₂, CO₂, CH₄
Moisture CompensationIntegrated Humidity Compensation Module
Temperature & Pressure CompensationAutomatic Real-Time Compensation
Heating ControlThermostatically Controlled Gas Cell
Linearity Error±2% FS
Repeatability±2% FS
Zero/Full-Scale Drift<2.5% FS per 7 days
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelPM2008MSE
Detection PrincipleOptical Scattering (Laser Nephelometry)
Measurement Range0–1000 µg/m³ (PM1.0, PM2.5, PM10)
Resolution0.3 µm
Accuracy (PM2.5)±10 µg/m³ (≤100 µg/m³), ±10% of reading (>100 µg/m³)
Accuracy (PM10)±20 µg/m³ (≤100 µg/m³), ±20% of reading (>100 µg/m³)
Data Update Interval1 s
Warm-up Time≤8 s
Operating Temperature−10 to +50 °C
Relative Humidity0–95% RH (non-condensing)
Storage Conditions−20 to +60 °C, 0–95% RH
Supply VoltageDC 5 V ±0.1 V (ripple <50 mV)
Operating Current≤100 mA
Standby Current≤200 µA
InterfaceUART (3.3 V logic), I²C (3.3 V logic)
Dimensions48 × 40 × 12 mm (W × H × D)
ShieldingFull-metal EMI enclosure
DesignUltra-thin profile (12 mm height)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-9050GHG
Instrument TypeOnline CEMS
Measured GasesCH₄, CO₂, CO, N₂O, O₂
Detection PrincipleNDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂)
RangeCH₄/CO/N₂O: 0–1000 ppm
CO₂/O₂0–25% vol
AccuracyCH₄/CO₂/CO/N₂O ≤ ±1% F.S.
Repeatability≤ ±1% F.S.
ResolutionCH₄/CO/N₂O: 1 ppm
CO₂/O₂0.01% vol
Response Time (T₉₀)< 25 s
Linearity ErrorCH₄/CO₂/CO/N₂O ≤ ±1% F.S.
Operating Flue Gas Temp.0–300 °C
Heated Line & Probe Temp.120–180 °C
Protection RatingIP54
Dimensions (L×W×H)800 × 760 × 1800 mm
Ambient Temp.−20 to +50 °C
Ambient Humidity< 95% RH (non-condensing)
Power Supply220 V AC ±10%, >3000 W
Compressed Air Requirement0.4–0.8 MPa, oil-free, dust-free, moisture-free
Max. Air Consumption2.2 m³/h
Avg.0.45 m³/h
Sample Flow RateMax. 2 L/min
Communication InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-2060
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasesSiF₄, CF₄, SF₆, NF₃, CO₂
Range1–264 ppm (0–200 mTorr)
Repeatability±0.5%
Linearity±1% F.S.
Detection Limit1 ppm
OutputAnalog (4–20 mA) & Digital (RS485/Modbus RTU)
DesignModular, Flange-Mountable (CF/KF compatible), Protocol-Ready for OEM Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGasboard-2102
PriceUpon Request
Measurement PrincipleNon-Dispersive Infrared (NDIR) with Microflow Dual-Chamber Detection
Target GasNitric Oxide (NO)
Range0–200 / 0–2000 / 0–5000 ppm (customizable)
Resolution1 ppm
Accuracy±25 ppm or ±4% of reading (whichever is greater)
Repeatability±20 ppm or ±3% of reading (whichever is greater)
Response Time (T90)≤4.5 s
Temperature & Pressure CompensationAutomatic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
ModelATRS-1010-P
Detection PrincipleMEMS-based Absolute Pressure Sensing
Measurement Range50–160 kPa
Full-Scale Peak Load600 kPa
Burst Pressure800 kPa
Resolution0.1 kPa
Accuracy≤ ±1.15 kPa (0–85 °C), ≤ ±1.725 kPa (−40–0 °C & 85–125 °C)
Response Time<1 s (pressure anomaly detection & wake-up signal to BMS), <50 ms (first CAN frame after BMS wake-up)
Output InterfaceCAN 2.0B, 500 kbps
Sampling Interval10 ms (normal mode), 1 s (low-power mode)
Power Supply9–16 VDC (nominal 12 VDC)
Operating Current20 mA (normal), <0.2 mA (low-power), <100 µA (sleep)
Operating Temperature−40 to +105 °C
Storage Temperature−40 to +125 °C
Humidity Range0–99% RH (non-condensing)
Enclosure MaterialUL94 V-0 flame-retardant polymer
Ingress ProtectionIP40
Design Lifetime>15 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
ModelGasboard-5260
Detection PrincipleMicroflow Dual-Chamber IR (NO), NDUV (NO₂), NDIR (HC, CO, CO₂), Electrochemical (O₂)
Measured GasesHC, NO, NO₂, CO, CO₂, O₂
AccuracyCompliant with JJG 688–2017 Class 00 & GB 18285–2018
Response Time (T₉₀)HC/CO/CO₂ ≤ 8 s
ResolutionNO/NO₂ = 1 ppm
Warm-up Time30 min
Power Supply100–240 VAC, 150 W
Communication InterfaceRS-485 / RS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3050-D
Measurement PrincipleCeramic Zirconia Electrolyte (O₂), Derived H₂O Calculation via O₂/H₂O Correlation
H₂O Range0–40 %v/v
O₂ Range0.1–25 %v/v
Accuracy±2 %F.S. (H₂O & O₂)
Repeatability±2 %
Sample Temp. Limit≤ 180 °C
OutputDual 4–20 mA, RS485 (standard), RS232 (optional), 3 x Relay Outputs
Power24 V DC, 50 W
InstallationWall-mounted probe + DIN-rail instrument housing
EnclosureNon-explosion-proof
Operating Ambient−10 to +50 °C, <90 %RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
ModelSF6+O2
Detection PrincipleNDIR for SF6
SF6 Range0–1500 ppm
O₂ Range0–25.0 %vol
SF6 Resolution1 ppm
O₂ Resolution0.1 %vol
SF6 Accuracy±2% FS
O₂ Accuracy±0.5% vol
SF6 Alarm ThresholdAdjustable (default 1000 ppm)
O₂ Alarm ThresholdAdjustable (default 18.0% vol)
Response Time (T90)≤60 s (diffusion mode) for both gases
Temperature Range−30 to +85 °C
Temp Accuracy±1 °C
Humidity Range0–99 %RH
RH Accuracy±5 %RH
PIR Detection Distance≥3 m
Dimensions205 × 105 × 58 mm
Weight<1.5 kg
Output InterfacesRS485, Wi-Fi, optional RS232
IP RatingIP54 (customizable)
Power SupplyAC 220 V ±10%, 50 Hz ±1%
Power Consumption<15 W
Design Life>10 years
ComplianceDL/T 1555–2016, DL/T 639, JB/T 10893
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Detection PrincipleNDIR & Electrochemical (ECD)
ConfigurationFixed-mount online analyzer
Response TimeT90 < 15 s (NDIR channels)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Explosion Protection RatingEx d IIC T6 / Ex tb IIIC T80°C Db
Measurement RangesCO/CO₂/CH₄/C₃H₈: 0–100% vol
O₂0–25% vol
H₂S0–9999 ppm
Accuracy±1% FS (NDIR gases), ±2% FS (O₂ & H₂S)
Repeatability≤2%
Resolution0.01% vol (low-range: 1 ppm for H₂S)
Sample Flow Rate0.7–1.2 L/min
Inlet Pressure2–50 kPa
Output InterfacesRS-485, RS-232, 4–20 mA, Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayBacklit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-3500
Measurement PrincipleNDIR & Electrochemical Detection
ConfigurationOnline Fixed Installation
Response TimeT90 < 15 s (NDIR)
Repeatability≤2% FS
Accuracy±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S)
Resolution0.01% vol (low-range: 1 ppm)
Measured GasesCO, CO₂, CH₄, C₃H₈, O₂, H₂S
Flow Rate0.7–1.2 L/min
Sample Pressure2–50 kPa
Output InterfacesRS-485 / RS-232 / 4–20 mA / Ethernet
Power SupplyAC 220 V, 50 Hz
DisplayLCD
Explosion ProtectionEx d IIC T6 Gb / Ex tb IIIC T80°C Db
Sample ConditioningIntegrated front-end pretreatment (particulate filtration, moisture removal, oil rejection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCubic
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGasboard-2063
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
ModelGasboard-5230
Instrument TypeOnline Analyzer
Measurement PrinciplesMicroflow Dual-Chamber Infrared (NO), Non-Dispersive Ultraviolet (NO₂), Non-Dispersive Infrared (CO₂)
Measured GasesCO₂, NO, NO₂
CO₂ Range(0.0–16.0) × 10⁻² vol% (±0.3 × 10⁻² vol% or ±3%), (16.01–18.0) × 10⁻² vol% (±5%)
NO Range(0–4000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%), (4001–5000) × 10⁻⁶ vol% (±8%)
NO₂ Range(0–1000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%)
ResolutionNO/NO₂: 1 ppm
CO₂0.01% vol
Response Time (T₉₀)CO₂ ≤ 8 s
Warm-up Time30 min
Communication InterfaceRS-485 / RS-232
Power Supply100–240 VAC, 150 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCUBIC INSTRUMENTS
OriginHubei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGasboard-2200
PriceUpon Request
Measurement PrincipleUV Differential Optical Absorption Spectroscopy (UV-DOAS)
Target GasesSO₂, NO, NO₂
SO₂/NO Range0–100 / 0–2000 ppm (configurable)
NO₂ Range0–500 / 0–5000 ppm (configurable)
Linearity Error±2% F.S.
Repeatability±2% F.S.
Zero/Full-Scale Drift<2.5% F.S. per 7 days
Light SourcePulsed Xenon Lamp
CompensationAutomatic Temperature & Pressure Compensation
Output InterfaceAnalog (4–20 mA) and Digital (RS485/Modbus RTU)
Module Form FactorOEM-integrated sensor unit