- All
- Favorite
- Popular
- Most rated
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6200 |
| Instrument Type | Portable |
| Measurement Principle | Diffusion Charging (DC) Method |
| Measured Component | Exhaust Particulate Number Concentration |
| Particle Size Range | ≥23 nm |
| Accuracy (Indication Error) | ≤±25% |
| Zero Drift | Not Specified |
| Span Drift | Not Specified |
| Repeatability | Not Specified |
| Response Time | <10 s (T₀–T₉₅) |
| Operating Temperature | 0–55 °C |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Startup Power Consumption | 700 W |
| Steady-State Power Consumption | 200 W |
| Dimensions (L×H×W) | 244 × 257 × 419 mm |
| Weight | <10 kg |
| Data Output Interface | RS-232 (optional RS-485, Bluetooth, 4G, Wi-Fi) |
| Heated Sample Line | AC-powered (110/230 V), customizable length |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-5260 |
| Detection Principle | Microflow Dual-Chamber IR (NO), NDUV (NO₂), NDIR (HC, CO, CO₂), Electrochemical (O₂) |
| Measured Gases | HC, NO, NO₂, CO, CO₂, O₂ |
| Accuracy | Compliant with JJG 688–2017 Class 00 & GB 18285–2018 |
| Response Time (T₉₀) | HC/CO/CO₂ ≤ 8 s |
| Resolution | NO/NO₂ = 1 ppm |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber Infrared (NO), Non-Dispersive Ultraviolet (NO₂), Non-Dispersive Infrared (CO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) × 10⁻² vol% (±0.3 × 10⁻² vol% or ±3%), (16.01–18.0) × 10⁻² vol% (±5%) |
| NO Range | (0–4000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%), (4001–5000) × 10⁻⁶ vol% (±8%) |
| NO₂ Range | (0–1000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%) |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01% vol |
| Response Time (T₉₀) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6200 |
| Instrument Type | Portable |
| Measurement Principle | Diffusion Charging Counting (DCC) |
| Measured Parameter | Particle Number Concentration in Exhaust Gas |
| Measurement Range | 5×10³–1×10⁷ #/cm³ |
| Particle Size Cut-off | ≥23 nm |
| Maximum Permissible Error | ≤±25% |
| Response Time (T₀–T₉₅) | <10 s |
| Operating Temperature | 0–55 °C |
| Power Supply | AC 100–230 V, 50–60 Hz |
| Startup Power Consumption | 700 W |
| Steady-State Power Consumption | 200 W |
| Heated Sample Line | AC-powered (110/230 V), customizable length |
| Output Interface | RS-232 (optional: RS-485, Bluetooth, 4G, Wi-Fi) |
| Dimensions (L×H×W) | 244×257×419 mm |
| Weight | <10 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805* |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Discharge CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC, NH₃, N₂O, PN (≥10 nm or ≥23 nm) |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–600 kg/h or 100–2000 kg/h |
| Exhaust Temp. Range | −5 to +500 °C |
| Battery Life | >8 h (Li-ion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9802 |
| Instrument Type | Online |
| Measurement Principle | Constant-volume dilution sampling with gravimetric and volumetric flow control |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Species | Diluted exhaust emissions from vehicles and engines |
| Dilution Exhaust Flow Ranges | 1–12 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3 / 6 / 9 L/min |
| Sample Bag Configuration | 3 diluted air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 diluted air |
| Particulate Sampling Chamber Temp. | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5230 |
| Instrument Type | Online Analyzer |
| Measurement Principles | Microflow Dual-Chamber NDIR (CO₂), PCT-Patented Microflow Infrared (NO), NDUV Absorption (NO₂) |
| Measured Gases | CO₂, NO, NO₂ |
| CO₂ Range | (0.0–16.0) × 10⁻² vol% (±0.3 × 10⁻² vol% or ±3%), (16.01–18.0) × 10⁻² vol% (±5%) |
| NO Range | (0–4000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%), (4001–5000) × 10⁻⁶ vol% (±8%) |
| NO₂ Range | (0–1000) × 10⁻⁶ vol% (±25 × 10⁻⁶ vol% or ±4%) |
| Resolution | CO₂: 0.01% vol |
| NO/NO₂ | 1 ppm |
| Response Time (T₉₀) | CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Communication Interface | RS-485 / RS-232 |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-9802 |
| Instrument Type | Online System |
| Measurement Principle | Dilution-based gravimetric/volumetric sampling with thermal and flow stabilization |
| Max. Permissible Error | ±2% (propane spike verification) |
| Measured Emission Sources | Laboratory-based exhaust testing of newly manufactured mobile sources (engines & light/heavy-duty vehicles) |
| Dilution Exhaust Flow Ranges | 1–12, 3–24, 9–60, or 30–150 m³/min |
| Diluted Exhaust Temperature Control | 40 ± 5 °C |
| Bag Sampling Flow Rates | 3, 6, or 9 L/min |
| Sample Bag Configuration | 3 dilution air bags + 3 diluted exhaust bags |
| Bag Chamber Temperature Control | 35 ± 5 °C |
| Particulate Sampling Flow | 35–65 L/min |
| Particulate Sampling Channels | 3 diluted exhaust + 1 dilution air |
| Particulate Sampling Box Temperature | 47 ± 5 °C |
| Dilution Air Filtration | Activated carbon + pre-filter + H13 HEPA filter |
| Operating Environment | 5–35 °C ambient temperature, ≤80% RH, 80–102 kPa atmospheric pressure |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Emission Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), Flame Ionization Detection (FID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Max. Permissible Error | ≤±2.0% of Reading Span (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5260 |
| Instrument Type | Online Analyzer |
| Detection Principles | Micro-flow Dual-chamber NDIR (for HC, CO, CO₂), NDUV (for NO₂), Micro-flow Dual-chamber IR (for NO), Electrochemical (for O₂) |
| Measured Gases | HC, CO, CO₂, NO, NO₂, O₂ |
| Measurement Ranges | HC (0–9999 ppm), CO (0.00–14.00% vol), CO₂ (0.0–18.0% vol), NO (0–5000 ppm), NO₂ (0–1000 ppm), O₂ (0.0–25.0% vol) |
| Accuracy | Compliant with JJG 688-2017 Class 00 and GB 18285-2018 |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.01% vol |
| Response Time (T90) | HC/CO/CO₂ ≤ 8 s |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Standard Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Filter-Based Nephelometry) |
| Max. Permissible Error | ±2.0% for Opacity (N) and Absorption Coefficient (K) |
| Opacity Range | 0–99.99% (Resolution: 0.1%) |
| K-Value Range | 0–16 m⁻¹ (Resolution: 0.01 m⁻¹) |
| Engine Speed | 400–6000 rpm (Resolution: 1 rpm |
| Accuracy | ±10 rpm or ±1%) |
| Ambient Temperature | −20–60 °C (Resolution: 0.1 °C |
| Accuracy | ±4% rel. or ±0.5 °C abs.) |
| Relative Humidity | 5–99% RH (Resolution: 0.1% RH |
| Accuracy | ±5% rel. or ±3% RH abs.) |
| Atmospheric Pressure | 70–106 kPa (Resolution: 0.01 kPa |
| Accuracy | ±5% rel. or ±2 kPa abs.) |
| Oil Temperature (optional) | 0–200 °C (Resolution: 1 °C |
| Accuracy | ±5 °C abs.) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000E |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Measured Gases | CO, HC, CO₂, NO, O₂ |
| Maximum Permissible Error | ±3% (full scale, typical range) |
| Zero Drift | ±2% FS |
| Span Drift | ±3% FS |
| Repeatability | <3% |
| Compliance | GB 18285–2018 (Class 00 Emission Testing Requirements) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6100 |
| Instrument Type | Benchtop/Stationary Headlamp Tester |
| Measurement Principle | Dual-Camera Optical Imaging & Digital Image Processing |
| Luminous Intensity Range | 0–120,000 cd |
| Vertical Beam Axis Deviation (High/Low Beam) | ±2.5° to ±3° |
| Horizontal Beam Axis Deviation (High/Low Beam) | ±3° |
| Headlamp Height Range | 350–1400 mm |
| Luminous Intensity Accuracy | ≤±10% (at zero angular deviation), ≤±12% (full range) |
| Beam Axis Angle Accuracy | ≤±10′ (≤±3.2 cm/dam) |
| Height Measurement Accuracy | ≤±10 mm |
| Operating Temperature | −10 to +40 °C |
| Power Supply | 100–240 VAC, 250 W |
| Dimensions (W×D×H) | 800 × 670 × 1700 mm |
| Weight | ~100 kg |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-6000 |
| Instrument Type | Portable |
| Measurement Principle | Transmissometry (Light Attenuation) |
| Measured Parameter | Visible Particulate Emissions from Compression-Ignition Engines |
| N Range | 0–99.99% |
| K Range | 0–16 m⁻¹ |
| Resolution | N ±0.1%, K ±0.01 m⁻¹ |
| Max Permissible Error | ±2.0% |
| Compliance | GB 3847–2018 |
| Temperature Control | Constant-Temperature Measurement Chamber |
| Output Interface | RS-232 / RS-485 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-5100 |
| Instrument Type | Online Analyzer |
| Detection Principles | UV-DOAS (NO, NO₂), NDIR (HC, CO, CO₂), Electrochemical (O₂) |
| Measurement Ranges | HC (0–2000 ppm), CO (0.00–10.00%), CO₂ (0.0–16.0%), NO (0–4000 ppm), NO₂ (0–1000 ppm), O₂ (0.0–25.0%) |
| Accuracy | ±4 ppm or ±3% (HC, 2000 ppm range), ±0.02% or ±3% (CO), ±0.3% or ±3% (CO₂), ±25 ppm or ±4% (NO), ±25 ppm or ±4% (NO₂), ±0.1% or ±5% (O₂) |
| Resolution | HC/NO/NO₂: 1 ppm |
| CO/CO₂/O₂ | 0.01% |
| Response Time (T90) | HC/CO/CO₂ ≤8 s |
| Warm-up Time | 30 min |
| Communication | RS-485 / RS-232 |
| Power Supply | AC 100–240 V, 50 Hz ±2% |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Basic Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Measuring Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Power Supply | Integrated Li-ion Battery (11.1 V / 35 Ah), ≥8 h continuous operation |
| Communication | Wi-Fi & Bluetooth |
| Data Output | Digital via USB/Bluetooth/Wi-Fi |
| Optional Accessories | HD Video Recording Module, Engine RPM & Oil Temperature Sensor Inputs |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Portable Engine Emission Analyzer |
| Instrument Type | Portable |
| Detection Principle | UV-DOAS / NDUV / NDIR |
| Max. Permissible Error | NO/NO₂: ±2% rel. or ±25 ppm abs. |
| CO₂ (0–16%) | ±3% rel. or ±0.3% abs., (16–18%): ±5% rel. |
| Opacity (K) | ±2.0% rel. |
| Measurement Range | NO: 0–4000 ppm |
| NO₂ | 0–1000 ppm |
| CO₂ | 0–18% vol |
| K | 0–16 m⁻¹ |
| Resolution | NO/NO₂: 1 ppm |
| CO₂ | 0.1% vol |
| K | 0.01 m⁻¹ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measured Gases | CO, CO₂, NO, NO₂, NOₓ, O₂, THC |
| Zero Drift | ≤±1% FS/8 h |
| Span Drift | ≤±1% FS/8 h |
| Repeatability | ≤±0.5% FS |
| Detection Principle | NDIR (CO, CO₂), NDUV (NO, NO₂), HFID (THC), Corona Charging + CPC (PN), Electrochemical/NDIR (NH₃/N₂O) |
| Operating Temperature | −10 to 45 °C |
| Relative Humidity | ≤90% RH |
| Altitude Range | 0–3000 m |
| Exhaust Flow Range | 10–2000 kg/h |
| THC Range | 0–10,000 ppmC |
| PN Size Cut-off | 10 nm or 23 nm |
| NH₃ Range | 0–1000 ppm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9805 |
| Instrument Type | Portable |
| Measurement Principles | NDIR (CO, CO₂, O₂), Electrochemical (O₂), UV-LED Differential Optical Absorption Spectroscopy (DOAS) for NO/NO₂ |
| Measured Gases | CO, CO₂, O₂, NO, NO₂, NOₓ (calculated) |
| Zero Drift (CO) | ≤±50 ppm / 4 h |
| Span Drift (CO) | ≤±2% of reading or ≤±50 ppm / 4 h |
| Resolution | CO/NO/NO₂: 0.1 ppm |
| CO₂/O₂ | 0.01% |
| Response Time (T₉₀) | ≤2.5 s (gas module) |
| Repeatability | Not specified |
| Optional Modules | Particulate Number (PN) counter (6×10²–1.3×10⁹ #/cm³, 23 nm–2.5 µm), Total Hydrocarbons (THC), Exhaust Flow Meter (EFM) with thermal mass flow principle, integrated GPS and environmental sensors (T, RH, Pₐₜₘ) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8220 |
| Instrument Type | Portable |
| Measurement Principle | Vibration & Ignition Pulse Spectrum Analysis |
| Measured Parameter | Engine Speed (RPM) |
| Measurement Range | Gasoline Engines: 400–8000 rpm |
| Diesel Engines | 400–6000 rpm |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 30–90 % RH |
| Power Supply | 12 VDC, 350 mA |
| Communication Interfaces | RS-232, TTL-level pulse output, analog ignition signal input |
| Display | LCD |
| Compliance | JJF 1375–2012 “Calibration Specification for Motor Vehicle Engine Tachometers” |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7800 |
| Instrument Type | Online |
| Measurement Principle | Ultrasonic & Vortex Shedding |
| Measured Components | O₂ |
| Flow Range | 4–12 m³/min |
| O₂ Range | 0.3–25% (v/v) |
| O₂ Resolution | 0.1% |
| O₂ Accuracy | ±0.1% (abs) or ±5% (rel) |
| Flow Accuracy | ±4% FS |
| Temperature Range | −30 to +150 °C |
| Temp Accuracy | ±1 °C |
| Pressure Range | 70.0–110.0 kPa |
| Pressure Accuracy | ±0.5 kPa or ±3% |
| Zero/Scale Drift (O₂) | ±2.5% FS |
| Repeatability | Flow ±2% FS |
| Response Time (O₂) | ≤5 s |
| Warm-up Time | <3 min |
| Humidity Range | 0–95% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-5230 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | Microflow Dual-Chamber NDIR (NO), NDUV (NO₂), NDIR (CO₂) |
| Measured Gases | NO, NO₂, CO₂ |
| Accuracy | ±25 ppm or ±4% (NO/NO₂) |
| Resolution | 1 ppm (NO/NO₂), 0.01% vol (CO₂) |
| Response Time (T₉₀) | ≤10 s (NO/NO₂), ≤8 s (CO₂) |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 150 W |
| Communication Interface | RS-485 / RS-232 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9801 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Non-Dispersive Ultraviolet (NDUV), Chemiluminescence Detection (CLD), and Flame Ionization Detection (HFID) |
| Measured Gases | THC, CH₄, NOₓ, CO, CO₂, O₂ |
| Maximum Permissible Error | ≤±2.0% of Reading Standard (RS) or ≤±0.3% of Full Scale (FS) |
| Zero Drift | ≤±1% FS / 8 h |
| Span Drift | ≤±1% FS / 8 h |
| Repeatability | ≤±0.5% FS |
| Response Time (T₁₀–₉₀) | <2.5 s |
| Linearity | R² ≥ 0.998 |
| Slope | 0.99–1.01 |
| Operating Environment | 5–40 °C, ≤80% RH |
Show next