- All
- Favorite
- Popular
- Most rated
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | CM2200 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| ETCO₂ Range | 0–150 mmHg (0–20 kPa at 760 mmHg) |
| ETCO₂ Resolution | 0.1 mmHg (0–49 mmHg), 0.2 mmHg (50–150 mmHg) |
| ETCO₂ Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% of reading (71–100 mmHg), ±10% of reading (100–150 mmHg) |
| Respiratory Rate Range | 2–150 breaths/min |
| Respiratory Rate Accuracy | ±1 breath/min |
| Communication Interface | TTL / RS-232 |
| Operating Conditions | 0°C–45°C, 10–90% RH (non-condensing) |
| Storage Conditions | −40°C–70°C, <90% RH (non-condensing) |
| Dimensions | 52 × 23 × 36 mm (W×H×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturing Type | OEM Sensor Component |
| Product Type | NOx Sensing Chip (HTCC-Based Electrochemical Platform) |
| Model | NOx Sensor Chip |
| Operating Principle | Potentiometric/Electrochemical Current Measurement |
| Measurement Range | 0–3076 ppm NOx |
| Operating Temperature | −40 °C to 1000 °C (exhaust-side) |
| Ambient Temperature Rating | −40 °C to 105 °C |
| Supply Voltage | 12 V / 24 V DC |
| CAN Interface | ISO 11898-2 compliant, 250 kbps baud rate |
| CAN Message Interval | 50 ms |
| Heater Power Consumption | Low-power integrated HTCC heater |
| Structural Design | Compact, high-vibration-resistant dual protective cap |
| Lifetime | Extended operational lifespan under cyclic thermal stress |
| Compliance | Designed for alignment with Euro VI, China VI, and EPA Tier 4 emission regulation monitoring requirements |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SJH |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol and 0–100% vol |
| Accuracy | ≤±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Output Options | Analog (4–20 mA / 0–5 V) and Digital (UART TTL/RS485) |
| Housing Material | Hermetically Sealed Metal Enclosure |
| Calibration | Full-Range Temperature Compensation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU4.9-based Wide-Range Oxygen Sensor |
| Pricing | Available Upon Request |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 7.5 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NOx/O₂ Dual-Gas Sensor |
| Voltage Range | 16–36 V DC |
| O₂ Measurement Range | 0–21% vol |
| NOx Measurement Range | 0–1500 ppm (NO + NO₂, λ > 1, NH₃-free environment) |
| NOx Accuracy | ±10 ppm (for [NOx] < 100 ppm) |
| Response Time (T₃₃–₆₆%) | NOx: 1200 ms (new generation), 1300 ms (legacy) |
| O₂ | 1000 ms (new), 1100 ms (legacy) |
| Fast Transient Response (T₁₀–₉₀%) | NOx: 100 ms |
| O₂ | 80 ms |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-ST-01 |
| Operating Principle | Zirconia Solid Electrolyte (Nernst Potential) |
| Supply Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Signal Output | Binary λ-switching voltage (≥750 mV at λ = 0.93–0.97 |
| Internal Resistance | ≤1 kΩ (at 150–930 °C) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms |
| Light-off Time | <15 s |
| Environmental Robustness | High tolerance to condensate, soot, and hydrocarbon fouling |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ATRS-1000 |
| Detection Principles | CO₂ – Dual-Beam NDIR |
| Measured Gases | CO₂ (0–10,000 ppm), CO (1–1,000 ppm) |
| Pressure Range | 40–180 kPa |
| Temperature Range | −40 °C to +125 °C |
| Resolution | 1 ppm |
| CO₂ Accuracy | ±(50 ppm + 3% of reading) |
| CO Accuracy | ±40 ppm or ±30% of reading (whichever is greater) |
| Pressure Accuracy | ±1 kPa |
| Temperature Accuracy | ±2 °C |
| T₉₀ Response Time | <25 s |
| Data Refresh Rate | ≤1 s |
| Output Interfaces | CAN, LIN, UART, Analog Voltage |
| Operating Temp/Humidity | −40 °C to +85 °C / 0–99% RH (non-condensing) |
| Storage Conditions | −40 °C to +110 °C / 0–99% RH (non-condensing) |
| Supply Voltage | 9–16 VDC (nominal 12 VDC) |
| Avg. Current Draw | ≤100 mA @ 12 VDC |
| Sleep Current | <100 µA |
| IP Rating | IP65 |
| Particle Measurement | Optical Scattering (0–5 mg/m³, ±10% accuracy, response <8 s) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBH |
| Price | USD 340 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range Options | 0–2% vol, 0–5% vol, 0–75% vol |
| Accuracy | ≤ ±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Output Interface | Dual-mode — analog (0–5 V / 4–20 mA) and digital (UART TTL/RS485) |
| Housing Material | Full-metal hermetic enclosure |
| Optical Design | Dual-beam NDIR with reference & measurement channels |
| Temperature Compensation | Full-range automatic compensation |
| Dimensions | Φ20 × 19 mm or Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU ADV Oxygen Sensor |
| Price | USD 47.20 (based on ¥330 at 1 USD = ¥7.0) |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Supply Voltage Range | 10.8–16.5 V DC |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Thread Size | M18 × 1.5 |
| Heater Steady-State Power | 8.7 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Measurement Accuracy (λ = 0.8) | Ip = −0.652 ± 0.032 mA |
| Measurement Accuracy (λ = 1.0) | Ip = −0.018 ± 0.008 mA |
| Measurement Accuracy (λ = 1.7) | Ip = 0.515 ± 0.022 mA |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRH |
| Price | USD 250 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Ranges | 0–5000 ppm |
| Accuracy | ±25 ppm or ±10% of reading (for ppm ranges) |
| Operating Temperature | −20 °C to +55 °C |
| Storage Temperature | −40 °C to +70 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Digital (UART TTL/RS485) and Analog (0–5 V / 4–20 mA) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-ST-09 |
| Application | Two-Wheeler Exhaust Lambda Monitoring |
| Detection Principle | Zirconia-Based Potentiometric (Limit-Current Type) |
| Operating Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Installation Thread | M12 × 1.25 |
| Signal Output Voltage (λ = 0.93–0.97) | ≥750 mV |
| Signal Output Voltage (λ = 1.05–1.10) | 50 ± 30 mV |
| Internal Resistance | ≤1 kΩ (at 850 °C: ≤0.5 kΩ) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms (at 850 °C: <60 ms) |
| Light-off Time | <15 s |
| Exhaust Moisture & Deposit Tolerance | High |
| Compliance | Designed for ISO 8767, SAE J167, and GB/T 20071-2022 (Motorcycle Emission Control Systems) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM1009 |
| Pricing | Available Upon Request |
| Detection Principle | Optical Transmission (Opposed-Beam) |
| Warm-up Time | 1 s |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Storage Temperature | −20 °C to +80 °C |
| Supply Voltage | DC 5.0 V ± 0.25 V (Ripple < 50 mV) |
| Operating Current | < 60 mA |
| Output Signal | PWM (3.3 V logic level) |
| Response Time | < 200 ms |
| Dimensions (PCBA only) | 43 mm × 25 mm × 5 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBrH |
| Price | USD 295 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol CH₃Br |
| Accuracy | ±0.06% vol (0–1% vol), ±6% of reading (1–5% vol) @ 25°C ±2°C, 101.3 kPa |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Analog (0–5 V / 4–20 mA) and Digital (UART TTL/RS485) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Oxygen Sensor Chip |
| Measurement Range | 0.98–1.02 (λ unit) |
| Operating Temperature | −40 °C to 1000 °C |
| Ambient Temperature Range | −40 °C to 105 °C |
| Supply Voltage | 12 V DC |
| Startup Time | ≤15 s to operational temperature (vs. >30 s for conventional thimble-type) |
| Heater Power Consumption | <12 W (typical at cold start) |
| Sensor Architecture | Multilayer ceramic planar element with integrated micro-heater and dual protective guard tubes |
| Aging Resistance | <±0.005 λ drift after 100,000 km simulated exhaust exposure (ISO 22738-compliant test cycle) |
| Poisoning Resistance | Validated against Pb, Si, P, and oil ash contaminants per SAE J1679 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-AFR-01 |
| Operating Voltage | DC 9–12 V |
| Storage Temperature | −40 °C to 90 °C |
| Operating Exhaust Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Heater Steady-State Power | 10 W |
| Measurement Accuracy (at λ = 1) | ±0.02 |
| Air–Fuel Ratio (AFR) Measurement Range | 0–2 (λ-equivalent) |
| Light-Off Time | < 15 s |
| Sensing Principle | Zirconia-based Solid Electrolyte (High-Temperature Nernst + Pump Cell Configuration) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | LSF XFOUR |
| Detection Principle | Zirconia Solid Electrolyte (Nernst Principle) |
| Operating Temperature Range | 150–930 °C |
| Storage Temperature | −40 to 90 °C |
| Exhaust Gas Temperature Rating | Up to 850 °C |
| Output Voltage (λ = 0.93–0.97) | 1005 ± 40 mV |
| Output Voltage (λ = 1.05–1.10) | 190 ± 30 mV |
| Internal Resistance | ≤2.5 kΩ (at cold start), ≤0.5 kΩ (at 850 °C) |
| Response Time (700 mV ↔ 400 mV) | <100 ms (cold), <80 ms (hot) |
| Light-off Time | <12 s |
| Thread Size | M18 × 1.5 |
| Heater Integrated | Yes |
| Reference Air Supply | Pumped (electrochemical oxygen pumping) |
| Sensor Type | Limiting-current / Concentration-cell (switch-type) lambda sensor |
| Core Substrate | HTCC (High-Temperature Co-fired Ceramic) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-WB4.2-01 (LUS4.2) |
| Detection Principle | Zirconia Solid Electrolyte High-Temperature Nernst Principle |
| Operating Voltage | DC 9 V |
| Storage Temperature | −40 °C to 90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 10 W |
| Nernst Cell Internal Resistance | 80 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
Show next