Synthesis/Reaction Equipment
Filter
Showing 421–450 of 735 results
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-H2G1A |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Temperature Range | 0–220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Volume | 40 L (cavity capacity) |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 1600 W (continuous, non-pulsed output) |
| Safety Leakage | <5 mW/cm² |
| Power Supply | 220 V AC / 50 Hz |
| Total Power Consumption | 3000 W |
| Net Weight | 80 kg |
| Dimensions (W×H×D) | 782 × 610 × 523 mm |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-H4D915 |
| Price Range | USD 21,000–42,000 (FOB) |
| Usable Volume | Large-scale (76 L cavity) |
| Construction Material | Industrial-grade 304 stainless steel with multi-layer PFA fluoropolymer coating |
| Operating Pressure Class | Medium-pressure rated (up to 2 MPa typical design) |
| Capacity | 76 L cavity volume |
| Microwave Frequencies | 2450 MHz (0–2400 W) and 915 MHz (0–1000 W), independently controllable |
| Temperature Range | 0–300 °C continuous |
| Temperature Measurement | Non-contact infrared pyrometry (0–500 °C) |
| Stirring Options | Dual-mode — overhead mechanical stirring + internal magnetic stirring, speed continuously adjustable |
| Control System | PLC-based intelligent controller with 7″ color touchscreen interface |
| Data Logging | Real-time dynamic curves (time/temperature/power), multi-segment program storage, USB export capability |
| Safety Compliance | Microwave leakage <5 mW/cm² (per GB 10436-2008), interlocked door safety, explosion-resistant viewport, integrated exhaust port, overtemperature/overpressure/overcurrent protection |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-H4G1A |
| Reactor Type | High-Pressure Batch Reactor |
| Vessel Capacity | 3 L |
| Working Pressure | Up to 3 MPa |
| Operating Temperature | Up to 220 °C |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 3200 W (continuous, non-pulsed) |
| Cavity Volume | 120 L |
| Construction Material | 304 Stainless Steel with Multi-Layer PTFE Coating |
| Stirring | Magnetic Stirring with PTFE-Coated Stir Bar |
| Temperature Sensing | Fiber-Optic Probe (Insertion Type) |
| Pressure Sensing | Integrated Piezoresistive Sensor |
| Microwave Leakage | <5 mW/cm² |
| Safety Compliance | ISO 9001 Certified |
| Power Supply | 220/380 VAC, 50 Hz |
| Total Power Consumption | 6 kW |
| Dimensions (W×H×D) | 920 × 966 × 685 mm |
| Net Weight | 120 kg |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-J4A |
| Temperature Range | 0–150 °C |
| Pressure Range | Atmospheric |
| Microwave Power | 4000 W (continuous, non-pulsed) |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Mechanical + Magnetic Stirring |
| Reaction Volume | 90 L (standard configuration: 4 parallel vessels) |
| Internal Cavity Dimensions | 550 × 300 × 550 mm (W × H × D) |
| Power Supply | 380 V AC / 50 Hz |
| Total Power Consumption | 6000 W |
| Weight | 80 kg |
| Microwave Leakage | <5 mW/cm² (compliant with GB 10436 & IEC 61000-3-2) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-WD6A |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Category | Reaction Vessel |
| Usable Volume | Large-scale (35 L cavity |
| Construction Material | AISI 304 Stainless Steel |
| Operating Pressure | High-pressure capable (vacuum-compatible) |
| Capacity | 35 L total cavity volume |
| Microwave Frequency | 2450 MHz |
| Max. Temperature | 1700 °C |
| Microwave Power Output | 6–30 kW (continuous, non-pulsed, infinitely variable) |
| Power Density | ≥170 W/L |
| Microwave Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |
| Compliance | ISO 9001 certified |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-XL10 |
| Usable Volume | Large (8 L) |
| Construction Material | 304 Stainless Steel |
| Operating Pressure | Medium-Pressure (up to 3 MPa) |
| Vacuum Capability | 3 MPa |
| Rated Microwave Power | 8000 W (2450 MHz, continuous non-pulsed output) |
| Max. Temperature | 220 °C |
| Max. Pressure | 3 MPa |
| Control System | PLC-based with touchscreen HMI |
| Safety Compliance | Microwave leakage < 5 mW/cm² (exceeding GB standard) |
| Weight | 120 kg |
| Dimensions (W×H×D) | 1100 × 1800 × 600 mm |
| Power Supply | 380 VAC / 50 Hz |
| Total Power Consumption | 15 kW |
| Certifications | ISO 9001 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MAM |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MaxiClave |
| Price Range | USD 135,000 – 270,000 (FOB) |
| Usable Volume | Medium-scale |
| Construction Material | ASTM A276 Type 316 Stainless Steel |
| Maximum Operating Pressure | Up to 700 bar (HPII) / 1000 bar (custom) |
| Nominal Capacity | 1000 mL |
| Ultimate Vacuum | ≤ 1×10⁻⁵ Torr |
| Temperature Range | −269°C to 1300°C (model-dependent) |
| Heating Configuration | Hot-wall or cold-wall variants available |
| Brand | PerfetLight |
|---|---|
| Origin | Beijing, China |
| Model | MCP-WS1000 |
| Temperature Range | 10–80 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Units | 9 |
| Reaction Vessel Capacity | 50 mL per unit |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | MCP-WS1000 |
| Temperature Range | 10–80 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Units | 9 |
| Reaction Volume per Unit | 50 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax 102 LT/ULT |
| Temperature Range | −90 °C to 150 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume per Vessel | 8–100 mL |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Real-Time Data Acquisition | Yes |
| Software Platform | iControl 6.1 |
| Low-Temperature Observation Capability | Yes (frost-free reactor wall down to −80 °C) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax/Optimax |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume Capacity | 8 mL to 1000 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax™ 102 HFCal |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessel Capacity | 8–1000 mL |
| Number of Reaction Units | 1–10 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasySampler 1210 |
| Temperature Range | –20 °C to 140 °C |
| Sample Type Compatibility | Homogeneous, heterogeneous, slurry, air- and moisture-sensitive, exothermic/hazardous reactions |
| Compliance | Designed for GLP/GMP-aligned workflows, supports 21 CFR Part 11–compliant data integrity when integrated with iC Software Suite |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | OptiMax™ |
| Temperature Range | −40 to 180 °C (jacket) |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Vessel Volume | 8–1000 mL |
| Stirring Speed | 30–1200 rpm (±5 rpm) |
| Dimensions | 388 × 414 × 539 mm (W × D × H) |
| Weight | 35 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RX-10 |
| Application Scope | Jacketed laboratory reactors (mL to L scale) |
| Integrated PAT Compatibility | In-situ pH, FTIR, FBRM, PVM, particle size analysis |
| Control Interface | Touchscreen + iC/iControl software suite |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signature, data integrity features |
| Thermal Control Integration | Compatible with external chillers, heaters, and circulators |
| Data Acquisition | Synchronized timestamped logging of temperature, stirring speed, dosing volume, pH, and PAT sensor streams |
| Brand | El-Mul Technologies |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MFC |
| Volume Capacity | Micro-scale (customizable) |
| Construction Material | Chemically resistant polymer & borosilicate glass components |
| Operating Pressure | Low-pressure (ambient to 0.2 bar gauge) |
| Compliance | Designed for laboratory-scale electrochemical and bioelectrochemical research |
| Brand | Microblox |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Microblox-Complex |
| Temperature Range | Customizable |
| Temperature Control Accuracy | Customizable |
| Reaction Units | Customizable |
| Reaction Volume | Customizable |
| Brand | Micromeritics |
|---|---|
| Origin | Spain |
| Model | FR-50, FR-100, FR-200 |
| Construction Material | Stainless Steel (316 SS) |
| Operating Pressure Range | Ambient to 100 bar or 200 bar (model-dependent) |
| Temperature Range | Ambient to 1000 °C |
| Number of Gas Inlets | Up to 6 |
| Mass Flow Controllers | Up to 6 integrated MFCs |
| Phase Separation | Integrated low-dead-volume gas–liquid or gas–liquid–liquid separator (US Pat. 7895891 B2 |
| Pressure Control Accuracy | ±0.1 bar (US Pat. 8740181 B2) |
| Safety System | Redundant pressure/temperature monitoring, automated shutdown, audible/visual alarms, fail-safe valve actuation |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ICCS |
| Quotation | Upon Request |
| Operating Pressure | Up to 20 bar(g) |
| Valve Box Temperature Range | Up to 180 °C |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HY-BH26 / HY-BH22 |
| Price | Upon Request |
| Frequency | 2.45 GHz |
| Waveguide Interface | BJ-26 (WR-340) / BJ-22 (WR-430) |
| Isolation | >20 dB |
| Insertion Loss (Forward) | ≤0.3 dB |
| VSWR | <1.2:1 |
| Power Handling | 1.5 kW CW |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKJ-J1-5 |
| Temperature Range | 0–300 °C |
| Pressure Condition | Ambient (Atmospheric) |
| Microwave Output Power | 800 W (0–900 W continuously adjustable) |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Mechanical Stirring |
| Reaction Vessel Capacity | 0.5 L |
| Power Supply | 220 V / 50 Hz |
| External Dimensions (W×D×H) | ≈500 × 220 × 500 mm |
| Microwave Leakage | Compliant with GB 4706.21 (Chinese National Standard for Microwave Oven Safety) |
| Control Interface | Rotary Knob + Digital Millisecond Timer |
| Optional Integration | RS232 Serial Interface, PLC Automation Upgrade |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MKE-5 |
| Pricing | Upon Request |
| Construction Materials | Glass / Stainless Steel (316L) / Hastelloy C-276 |
| Vessel Capacities | 5–250 L (Standard Options: 5, 10, 20, 50, 63, 100, 250 L) |
| Temperature Range | −50 °C to +200 °C (Optional: −90 °C to +250 °C) |
| Absolute Pressure Range | 0.01–1.5 bar (Optional: 0.001–4 bar) |
| Process Capabilities | Multi-component synthesis, liquid–liquid extraction, phase separation, simple & fractional distillation, azeotropic distillation with phase split, evaporation, concentration, crystallization |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Makewave Co., Ltd. |
| Model | MKM-RH1P |
| Temperature Range | 0–1500 °C |
| Microwave Power | 0–500 W (2450 MHz, continuous non-pulsed output) |
| Reaction Volume | 1–10 mL |
| Cavity Volume | ~150 mL |
| Safety Leakage | <5 mW/cm² |
| Power Supply | 220 V AC / 50 Hz |
| Dimensions (W×H×D) | 500×400×400 mm |
| Weight | 50 kg |
| Compliance | ISO 9001 certified |
| Brand | Makewave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKX-H1C1U |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Vessel | Three-Neck Round-Bottom Flask |
| Maximum Reaction Volume | 500 mL |
| Microwave Frequency | 2450 MHz |
| Microwave Power Output | 0–800 W (Continuously Adjustable, Non-Pulsed) |
| UV Wavelength | 254 nm |
| Cooling Requirement | External Chilled Water Circulation |
| Power Supply | 220 V AC / 50 Hz |
| Total Power Consumption | ≤1500 W |
| Net Weight | 60 kg |
| Dimensions (W×H×D) | 782 × 492 × 450 mm (Main Unit), +500 mm Height for Optional UV Mounting Bracket |
| Brand | Moorfield |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | Moorfield Desktop Series (oCVD, oPVD, oETCH, ANNEAL, oEM, MiniLab) |
| Pricing | Available Upon Request |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NAAI-DMH |
| Pricing | Available Upon Request |
| Brand | NAI |
|---|---|
| Origin | Shanghai, China |
| Model | NAI-WBC6 / NAI-WBC12 |
| Sample Capacity | 6 or 12 vessels |
| Vessel Material | PTFE inner + PEEK outer |
| Inner Volume | 100 mL per vessel |
| Temperature Range | 0–300 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Pressure Range | 0–10 MPa |
| Microwave Output | 0–1600 W, continuous auto-frequency modulation |
| Safety features | self-locking anti-explosion door, rupture disc + pressure relief valve, real-time fault diagnostics, automatic microwave cutoff on overpressure/overtemperature |
| Cooling | forced-air circulation ≥5 m³/min, integrated cavity air-cooling |
| Display | 8″ industrial touch HMI (Siemens PLC-based) |
| Brand | Newport Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lab-Scale High-Pressure Reactor Series |
| Price | USD $50,000 |
| Usable Volume Range | 23–4520 mL |
| Construction Material | Modular Corrosion-Resistant Alloy with Interchangeable Liners |
| Operating Pressure | Up to 139 MPa (20,000 psi) |
| Vacuum Capability | 46–139 MPa (absolute, gauge-referenced) |
| Oscillation Angle | 30° |
| Oscillation Frequency | 36 cycles/min |
| External Drive Motor | Integrated AC Servo |
| Pressure Gauge | Dual-scale Analog + Digital Output |
| Heating Jacket | Segmented Resistive Heating with Independent Thermal Zones |
| Liner Options | Removable Pyrex® Glass, Electroless Nickel-Coated Stainless Steel, or Custom Alloy Liners |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | DN15 Series |
| Price Range | USD 110,000 – 138,000 |