Testing Machine
Filter
Showing 301–330 of 3402 results
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-AII |
| Impact Energy Range | 50–300 J |
| Impact Velocity | 2–5.5 m/s |
| Pendulum Torque (Impact Constant) | 15 N·m |
| Load Cell Capacity | 16 kN |
| Maximum Lifting Height | 1500 mm |
| Temperature Chamber Range | −40 °C to +100 °C |
| System Sampling Rate | 2 MHz |
| A/D Resolution | 16-bit |
| Frequency Response | 500 kHz |
| Dynamic Test Error | <2% |
| Overall Dimensions (w/o chamber) | 850 × 1700 × 3300 mm |
| Net Weight | 1200 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-B6 |
| Price | USD 2,350 (approx.) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Standards Compliance | GB/T 1411-2002, IEC 61621:1997, ASTM D495, IEC 149, UL 746A |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Range | 10–40 mA (selectable steps) |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Arc On/Off Timing Error | < ±1 ms |
| Electrode Force | 0.5 ± 0.05 N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | 6.35 ± 0.1 mm (IEC), 6.0 ± 0.1 mm (ASTM) |
| Input Power | 220 V AC, 50 Hz |
| Transformer Capacity | 3 kVA |
| Output Voltage Range | 0–17.5 kV AC |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Series | ML Series |
| Actuation Type | Electro-Hydraulic Servo Fatigue Actuator |
| Maximum Test Force | 10–1000 kN |
| Frequency Range | 0.01–400 Hz |
| Host Weight | 35–1380 kg |
| Operating Pressure | 21–28 MPa |
| Peak Velocity (Standard) | 20 m/s |
| Bearing Type | Hydrostatic Journal Bearing (Sealless) |
| Compliance | ISO 6892-1, ASTM E4, ASTM E606, ASTM E2207 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #305 |
| Instrument Type | Portable Mechanical Impact Tester |
| Measuring Range | 0–90 N (continuously adjustable) |
| Indentor Diameter | 5 mm |
| Unstretched Length | 245 mm |
| Net Weight | Instrument: ~340 g |
| Enamel Test Plate Holder | ~25 g |
| Plastic Surface Test Fixture (Ø120 mm) | ~3000 g |
| Actuation Mechanism | Mechanical Spring-Loaded |
| Locking Mechanism | Mechanical Latch |
| Compliance | DIN 51155 |
| Brand | ENSOUL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETS-HPro / ETS-HTouch |
| Price | Upon Request |
| Torque Sensor Options | 0.1 / 0.2 / 0.3 / 1 / 1.5 / 3 / 6 N·m |
| Accuracy | ±0.5% of Full Scale |
| Resolution | 1:50,000 |
| Axial Load Capability | Yes (simultaneous axial force application during torsion) |
| Compliance | ISO 9001–certified manufacturing |
| Software | VPro with FDA 21 CFR Part 11–compliant audit trail and role-based user permissions |
| Brand | ENSOUL |
|---|---|
| Model | Orbis |
| Type | Manual Digital Torque Tester |
| Measurement Range | 0–6 N·m (0–50 lbf·in) |
| Display | High-resolution digital LCD |
| Sampling Rate | ≥1 kHz |
| Power Supply | AC adapter or rechargeable battery |
| Output Interface | RS232 serial port |
| Operating Direction | Bidirectional (clockwise & counterclockwise) |
| Construction | Rigid aluminum alloy frame with integrated load cell base |
| Weight | <2.5 kg |
| Dimensions | 180 × 120 × 240 mm (W × D × H) |
| Compliance | CE, RoHS |
| Software Compatibility | VectorPro Lite (data logging, real-time curve plotting, peak hold, statistical export) |
| Brand | ENSOUL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TVG Tornado |
| Torque Range | 1.5–10 N·m |
| Display | Full-Color Touchscreen LCD |
| Operation Mode | Manual Handwheel-Driven |
| Security | Password-Protected User Access |
| Alarm Configuration | 5 Programmable Threshold Alerts |
| Software Compatibility | VectorPro Lite (Data Visualization & Real-Time Curve Plotting) |
| Compliance | Designed for ASTM D3474, ISO 8504-2, and USP <1217> torque verification protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #304 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #494 |
| Price | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #525 Series |
| Pricing | Available Upon Request |
| Brand | Erichsen |
|---|---|
| Origin | Germany |
| Model | 145-60 / 145-100 |
| Maximum Punch Force | 600 kN / 1000 kN |
| Maximum Blank Holder Force | 600 kN / 1000 kN |
| Maximum Shearing Force | 700 kN / 1000 kN |
| Max. Punch Diameter | 100 mm |
| Max. Stroke | 150 mm (250 mm optional) |
| Blank Holder Stroke | 38 mm |
| Ejector Stroke | 150 mm |
| Max. Specimen Diameter | 220 mm |
| Punch Speed | up to 750 mm/min |
| Cupping Test Thickness Range | 0.1–6.0 mm |
| Deep Drawing Thickness Range | 0.2–3.0 mm (up to 6.0 mm for Model 145-100) |
| Hole Expansion Thickness Range | 0.2–3.0 mm |
| Operating Temperature | up to 550 °C (high-temp configuration available) |
| Brand | ERICHSEN |
|---|---|
| Origin | Germany |
| Model | 145-60 / 145-100 |
| Maximum Punch Force | 600 kN / 1000 kN |
| Maximum Blank Holder Force | 600 kN / 1000 kN |
| Maximum Shearing Force | 700 kN / 1000 kN |
| Max. Punch Diameter | 100 mm |
| Max. Stroke | 150 mm (250 mm optional) |
| Blank Holder Stroke | 38 mm |
| Ejection Stroke | 150 mm |
| Max. Specimen Diameter | 220 mm |
| Punch Speed | up to 750 mm/min |
| Cupping Test Thickness Range | 0.1–6.0 mm |
| Deep Drawing Thickness Range | 0.2–3.0 mm (up to 6.0 mm for 145-100) |
| Hole Expansion Thickness Range | 0.2–3.0 mm |
| Operating Temperature | up to 550 °C (high-temp module available) |
| Control Mode | Manual & PC-based real-time control |
| Safety Compliance | EN ISO 13857, EN 692 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 100–300 RPM (1.67–5 Hz) |
| Amplitude | 25.4 mm (1 inch) peak-to-peak |
| Max Load Capacity | 100 kg (customizable) |
| Timer Range | 0–9999 h/min/sec |
| Motor Power | 1 HP (746 W) |
| Max Current | 4 A |
| Table Dimensions | 100 cm × 120 cm (customizable) |
| Drive System | Synchronous toothed belt transmission |
| Mounting Interface | Linear rail-based fixture system |
| Base Construction | Heavy-duty C-channel frame with vibration-damping rubber mounts |
| Compliance | ASTM D999, ASTM D3580, ISTA 3A/3E/3H, EN 15308, ANSI/UL 60730, ISO 13374-2 |
| Brand | Fangyuan Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GB7706 |
| Quotation | Upon Request |
| Specimen Area | 60 × 210 mm |
| Rubbing Speed | 4 adjustable speeds (21 / 42 / 85 / 106 cycles per minute) |
| Applied Load | 4.5 lb (2.04 kg, 20 N) |
| Stroke Length | 60 mm |
| Cycle Count Range | 0–999,999 (auto-stop) |
| Rubbing Contact Area | 50 × 100 mm |
| Power Consumption | 40 W |
| Dimensions (W×D×H) | 300 × 325 × 300 mm |
| Net Weight | 20 kg |
| Input Voltage | AC 220 V, 1 A |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Model | PZY-200 |
| Cutting Display Resolution | 0.01 mm |
| Dimensional Accuracy | ±1 mm |
| Worktable Dimensions | 1000 × 700 mm |
| Effective Travel of Movable Worktable | 500 mm |
| Power Supply | 380 V AC |
| Rated Power | 2.2 kW |
| Specimen Size | 25 × 25 × 10 mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Formastor-F |
| Price | USD 280,000 (FOB Japan) |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-1209 |
| Price Range | USD 1,400–7,200 (based on configuration) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN, 2 kN, 5 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.3% of reading |
| Travel Resolution | 0.005 mm |
| Crosshead Speed Range | 0.5–500 mm/min (software-controlled) |
| Maximum Travel | 350 mm |
| Test Width | 420 mm |
| Control Interface | PC-based with USB connectivity |
| Data Acquisition | Real-time force/displacement sampling with curve plotting |
| Compliance Standards | ISO 7500-1, ASTM E4, DIN 51221, JIS B7721/B7733, EN 10002-1, GB/T 228.1, JJG 475 |
| Brand | YUELIAN / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PW-6603 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 480V & 490V |
| Torque Range | 0.071–1.412 N·m |
| Output | ±5 V DC (clockwise/counterclockwise) |
| Accuracy (combined) | ±0.15% FS |
| Nonlinearity | ±0.1% FS |
| Hysteresis | ±0.1% FS |
| Nonrepeatability | ±0.06% FS |
| Rotational Effect on Zero | ±0.05% FS |
| Remote Calibration Accuracy (75°F, NIST-traceable) | ±0.05% FS |
| Temperature Effect (Zero) | ±0.003% FS/°F |
| Temperature Effect (Span) | ±0.003% reading/°F |
| Compensated Temp Range | +75 to +175°F |
| Operating Temp Range | −25 to +185°F |
| Storage Temp Range | −65 to +225°F |
| Bandwidth (High-Freq Output) | DC–500 Hz |
| Bandwidth (Low-Freq Output) | DC–1 Hz |
| Input Power | 10.5–24 VDC @ 85 mA nominal |
| EMI Immunity | Enhanced against IGBT-based ASD noise |
| Max Speed Rating | 25,000 rpm |
| Optional Encoder | Dual-track 512 PPR with line driver |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FY-LLWF |
| Pricing | Available Upon Request |
| Reciprocating Stroke | 75 mm |
| Lateral Clamp Width | 25 mm |
| Longitudinal Clamp Mass | 0.28–0.34 kg |
| Center-to-Center Distance Between Clamps | 6.35 mm |
| Sample Opening Angle | 60° |
| Sample Meshing Angle | 30° |
| Counter | LCD, 0–999,999 cycles |
| Power Supply | 1-phase AC 220 V, 3 A |
| Test Speed | 30 cycles/min (constant velocity) |
| Compliance Standard | CNS 1083 |
| Brand | Galdabini |
|---|---|
| Origin | Italy |
| Model | Impact25 |
| Maximum Impact Energy | 25 J |
| Test Configurations | Charpy (simply supported beam), Izod (cantilever beam), and Tensile Impact |
| Compliant Standards | ASTM D256, ASTM D6110, ISO 180, ISO 179, DIN 53438, EN ISO 8256, JIS K7111 |
| Control System | Microprocessor-based with automatic friction compensation |
| Data Interface | RS-232 serial port |
| Software Support | GraphWork data analysis suite |
| Certification | Manufactured in accordance with ISO 9001 quality management system |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-762DQ |
| Price Range | USD 14,000–42,000 |
| Instrument Type | Specialized Fatigue Tester for Footwear |
| Frequency Range | 60 cycles/min |
| Test Angle | 45° ± 1° |
| Sample Capacity | 2 shoes simultaneously |
| Actuation Mechanism | Dual Humanoid Metal Foot Formers |
| Control System | PLC-based with Touchscreen HMI |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 110 kg |
| Memory Function | Power-Failure Resume Capability |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Equipment Co., Ltd. |
| Model | GBD-I1 |
| Instrument Type | Dart Impact Tester |
| Impact Mass Range | 50–2000 g (5 g increments, mass tolerance ≤ ±0.5%) |
| Dart Tip Diameter | A-method: 38 ± 1 mm |
| B-method | 50 ± 1 mm |
| Clamp Dimensions | Outer Ø 150 mm, Inner Ø 125 mm |
| Maximum Drop Height | 1500 mm (standard), 660 mm (low-height configuration) |
| Force Sensor Capacity | 50 kg |
| Test Accuracy | ±1 g |
| Compliance Standards | ISO 7765-1, ASTM D1709, GB/T 9639, GB/T 15267, JIS K7124 |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 650 × 650 × (2200–2600) mm |
| Net Weight | 50 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GBG-L2 |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 5 J (8 J optional) |
| Energy Resolution | 0.001 J |
| Pendulum Lift Angle | 90° |
| Pendulum Radius | 285 mm |
| Impact Tip Diameter | Φ19 mm and Φ25.4 mm |
| Clamp Aperture | Φ60 mm and Φ89 mm |
| Specimen Size | 100 mm × 100 mm |
| Dimensions (L×W×H) | 773 mm × 378 mm × 606 mm |
| Power Consumption | 75 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 5 J (8 J optional) |
| Resolution | 0.001 J |
| Pendulum Lift Angle | 90° |
| Pendulum Radius | 285 mm |
| Impact Tip Diameter | Φ19 mm / Φ25.4 mm |
| Clamp Aperture | Φ60 mm / Φ89 mm |
| Specimen Size | 100 mm × 100 mm |
| Dimensions (L×W×H) | 773 mm × 378 mm × 606 mm |
| Power Consumption | 75 W |
| Supply Voltage | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBH-1AT |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Load | 1.5 kN |
| Force Range | 0–500 N (optional 0–1500 N) |
| Elongation Capacity | up to 1400% |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Crosshead Travel | 750 mm |
| Displacement Resolution | ±0.5% of reading |
| Effective Specimen Width | 30 mm (customizable to 50 mm) |
| Test Speed | 0–500 mm/min (infinitely variable) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Dimensions (W×D×H) | 600 × 600 × 1300 mm |
| Weight | 70 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GBH-1C |
| Maximum Test Load | 0.5 kN (500 N) |
| Force Measurement Range | 0–500 N |
| Elongation Capacity | up to 1500% |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Crosshead Travel | 750 mm |
| Displacement Resolution | ±0.5% of reading |
| Test Speed Range | 0–500 mm/min (infinitely variable) |
| Specimen Width Limit | ≤30 mm |
| Dimensions (W×D×H) | 600 × 600 × 1300 mm |
| Weight | 70 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance Standards | GB 8808, GB 13022, GB/T 1040, ASTM D882, ASTM D1938, ISO 37, JIS P8113, YBB pharmaceutical packaging standards, and others |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBH-1D |
| Instrument Type | Electronic Tensile Tester |
| Max Test Load | 0.5 kN |
| Force Range | 0–500 N, 1500% Elongation |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Travel Distance | 750 mm |
| Displacement Resolution | ±0.5% of reading |
| Speed Range | 0–500 mm/min (infinitely variable) |
| Specimen Width Capacity | ≤30 mm |
| Dimensions | 600 × 600 × 1300 mm |
| Weight | 70 kg |
| Power | 1000 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GBH-1F |
| Max Test Load | 1.5 kN |
| Force Range | 0–500 N (optional 0–1500 N) |
| Extension Capacity | up to 1400% |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Crosshead Travel | 750 mm |
| Displacement Resolution | ±0.5% of reading |
| Effective Sample Width | 30 mm (customizable to 50 mm) |
| Test Speed | 0–500 mm/min, continuously variable |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 1000 W |
| Dimensions (W×D×H) | 600 × 600 × 1300 mm |
| Weight | 70 kg |
| Sampling Rate | 100 Hz |
| Compliance | ASTM D882, ASTM D1938, ASTM F88, ISO 37, GB/T 1040, GB/T 8808, YY/T 0681, YBB pharmaceutical packaging standards, JJG 139 |
| Brand | GBPI |
|---|---|
| Model | GBH-1G |
| Type | Electronic Tensile Testing Machine |
| Max Test Load | 1.5 kN |
| Force Range | 0–500 N (optional 0–1500 N) |
| Force Accuracy | ±0.5% of reading (Class 0.5) |
| Elongation Capacity | up to 1400% |
| Crosshead Travel | 750 mm |
| Displacement Resolution | ±0.5% of reading |
| Effective Specimen Width | 30 mm (customizable to 50 mm) |
| Test Speed | 0–500 mm/min, continuously variable |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 1000 W |
| Dimensions (W×D×H) | 600 × 600 × 1300 mm |
| Weight | 70 kg |