Thermal Analysis Instruments
Filter
Showing 391–420 of 922 results
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | THB L56 |
| Thermal Conductivity Range | 0.005–1800 W/(m·K) |
| Sample Types | Solids, Powders, Gels, Liquids |
| Standards Compliance | ASTM D5930-01, ISO 22007-2, ASTM D5334 |
| Measurement Principle | Transient Hot Bridge (THB) |
| Temperature Range (Sensor) | −150 to 700 °C |
| Typical Measurement Time | 1–10 min (solids), 1–120 s (liquids) |
| Specific Heat Capacity Range | 0.1–5 J/(g·K) |
| Thermal Diffusivity Range | 0.05–1200 mm²/s |
| Minimum Sample Size | 1.5 × 1.5 × 2 mm |
| Sensor Materials | Polyimide, Ceramic |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TIM-Tester (TIM L58) |
| Measurement Principle | Laser Flash Method (ASTM D5470–17 compliant) |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature operation |
| Accuracy | ±0.1% at 50% stroke, ±0.25% at 100% stroke |
| Thermal Conductivity Range | 0.1–50 W/(m·K) (extendable upon configuration) |
| Sample Forms | Solid, powder, paste, liquid, adhesive, foil |
| Sample Dimensions | Circular Ø20/25/40 mm |
| Thermal Resistance Range | 0.01–8 K/W |
| Temperature Range | −30 °C to 300 °C (configurable) |
| Contact Pressure | 0–16 MPa (dependent on sample area) |
| Cooling System | External water-cooling unit |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TMA L71 (TMA PT1000) |
| Temperature Range | –260 to 1000 °C |
| Force Range | up to 1 / 5.7 / 20 N |
| Frequency Range | 1 Hz |
| Resolution | 0.125 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Static or Dynamic |
| Sample Dimensions | up to 30 mm × 30 mm |
| Interface | USB |
| Optional Modules | DTA Analysis Software, Rate-Controlled Sintering (RCS) Software |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | TMA L72 (TMA PT1600) |
| Temperature Range | RT to 1600 °C |
| Force Range | up to 1 N or 5.7 N |
| Frequency Range | 1 Hz or 5 Hz |
| Resolution | 0.125 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Static/Dynamic |
| Sample Max Height | 30 mm |
| Interface | USB |
| Optional Modules | DTA Analysis Software, Rate-Controlled Sintering (RCS) Software |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | M3350-MFI |
| Temperature Range | 50–350 °C |
| Calibration Accuracy | ±0.1 °C |
| Temperature Stability | ±0.5 °C |
| Standard Load Masses | 1.2, 2.16, 3.8, 5, 10, 21.6 kg |
| Test Modes | MFR (Melt Flow Rate) and MVR (Melt Volume Rate) |
| Heating Zones | Dual-zone PID-controlled |
| Interface | RS-485 / RS-232 |
| Power Supply | 230 V / 50 Hz |
| Pneumatic Actuation | Dry air, 3 bar |
| Dimensions (L×W×H) | 60×30×40 cm |
| Weight | 15 kg |
| Software Compatibility | Windows 98/ME/2000/XP |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682, USP <661>, DIN 53735 |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-G1A |
| Price Range | USD 14,000–28,000 (FOB) |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated Microwave TGA System |
| Temperature Range | 0–300 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Uniformity | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Maximum Sample Mass | 500 g |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Cavity Volume | ~20 L |
| Balance Resolution | 0.01 g |
| Exhaust Mode | Negative-Pressure Ventilation |
| Safety Leakage | <5 mW/cm² (per GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dedicated Microwave TGA |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (Continuously Adjustable, Non-Pulsed) |
| Balance Capacity | 50 g |
| Balance Resolution | 0.001 g |
| Chamber Volume | ~8 L |
| Microwave Leakage | <5 mW/cm² (Compliant with GB 10436 & IEC 62233) |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MKC-R1A |
| Price Range | USD 14,000–28,000 |
| Temperature Range | 0–900 °C |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Brand | MakeWave |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MKC-R1B |
| Price Range | USD 14,000–28,000 (FOB) |
| Temperature Range | 0–800 °C (up to 900 °C for short-term operation) |
| Temperature Accuracy | ±3 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | Up to 100 K/min |
| Microwave Frequency | 2450 MHz |
| Rated Microwave Power | 800 W (continuously adjustable, non-pulsed) |
| Balance Capacity | 50 g |
| Internal Cavity Volume | ~500 mL |
| Microwave Leakage | <5 mW/cm² |
| Compliance | ISO 9001 certified |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | MicroCal PEAQ-DSC Automated |
| Sample Throughput | Up to 50 samples per unattended run |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Sample Format | Standard 96-well microplate compatibility |
| Regulatory Compliance | Designed for 21 CFR Part 11 and EU GMP Annex 11 compliance support |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-DSC |
| Sample Throughput | Multiple samples per run (manual loading) |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –10 °C to 130 °C (expandable) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC Automated |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Volume Requirement | As low as 10 μg protein per experiment |
| Throughput | Fully automated operation supporting up to four 96-well plates per unattended run |
| Detection Sensitivity | Sub-micromolar to picomolar dissociation constants (KD = 10⁻² – 10⁻¹² M) |
| Cell Material | Chemically resistant nickel-based alloy |
| Cell Geometry | Optimized coin-shaped reaction cell for efficient mixing and minimal sample dispersion |
| Brand | Malvern PANalytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | MicroCal PEAQ-ITC |
| Measurement Mode | Isothermal Titration Calorimetry (ITC) |
| Temperature Range | 2 °C to 80 °C |
| Sample Consumption | As low as 10 µg protein per experiment |
| Affinity Range | 10² M⁻¹ to 10¹² M⁻¹ (K<sub>D</sub> = 10⁻² to 10⁻¹² M) |
| Compatibility | Aqueous and non-aqueous solvents |
| Cell Material | Chemically resistant nickel-based alloy |
| Upgrade Path | Compatible with MicroCal PEAQ-ITC Automated platform |
| Brand | MATHIS |
|---|---|
| Origin | Canada |
| Model | TC-30 |
| Measurement Principle | Transient Plane Source (TPS) or Modified Transient Hot Wire (THW) |
| Sample Measurement Time | 1–60 s |
| Inter-Test Interval | 0–10 min (typ. 2 min) |
| Operating Temperature Range | –20 °C to +60 °C (external sensor) |
| Compliance | Designed for GLP/QC environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC1 |
| Heating Rate | up to 2,400,000 K/min |
| Cooling Rate | up to 240,000 K/min |
| Sensor Type | UFS1 MEMS-based chip sensor with 16 thermocouple pairs (8 on sample side, 8 on reference side) |
| Time Constant | ~1 ms |
| Measurement Principle | Dynamic power-compensated differential scanning calorimetry |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+ 300 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –150 °C to +500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±150 N (peak-to-peak: 300 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (up to 1000 Hz with optional high-frequency module) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.05 µm |
| Stiffness Measurement Span | >7 decades (250 Pa to 3×10¹² Pa) |
| Environmental Control Options | O₂ concentration control (10 ppm–20% vol), cryogenic cooling (LN₂ or air-cooled to –150 °C) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+1000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | −500 N to +500 N (peak-to-peak: 1000 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.1 µm |
| Maximum Measurable Modulus | 3×10¹² Pa |
| Dynamic Modulus Range | 6 decades |
| Environmental Control Options | O₂ concentration control (10 ppm–20% O₂), forced-air cooling (−70 °C), liquid nitrogen cooling (−150 °C) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+1000 / DMA+2000 + Xpander |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Automation Level | Fully Automated Robotic System |
| Compliance | Designed for ISO 6721, ASTM D4065, ASTM D7028, ISO 11359-2, and USP <1031> compliant testing environments |
| Operating Modes | Tension, Compression, Dual Cantilever, Single Cantilever, Shear |
| Sample Capacity | Up to 120 specimens per rack (configurable) |
| Footprint | < 1.2 m² |
| Control Interface | Touchscreen HMI + Ethernet-connected PC workstation |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+2000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | −1000 N to +1000 N (peak-to-peak: 2000 N) |
| Displacement Range | ±6 mm (peak-to-peak: 12 mm) |
| Frequency Range | 1×10⁻⁵ Hz to 200 Hz (optional up to 1000 Hz) |
| Minimum Detectable Force | 0.01 N |
| Minimum Detectable Displacement | 0.1 µm |
| Modulus Measurement Range | 500 Pa to 3×10¹² Pa (6 decades) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA+NG |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) with Integrated Crack Growth Module |
| Temperature Range | −150 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 0.1–500 N |
| Displacement Range | 0.1–6000 µm |
| Frequency Range | 10⁻⁵–200 Hz |
| Crack Measurement Channels | 2 or 4 simultaneous crack tip tracking positions |
| In-situ Initial Crack Generation | Yes, inside climate-controlled chamber |
| Chamber Oxygen Control | 10 ppm–20% O₂ adjustable |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | DMA25/50 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 500 °C (upgradable to 600 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Ramp Rate | ±0.1 to ±10 °C/min |
| Dynamic Force Range | ±25/±50 N (peak-to-peak: 50/100 N) |
| Displacement Range | ±3/±6 mm |
| Frequency Range | 1×10⁻⁵ to 200 Hz |
| Modulus Range | 10⁵ to 10¹¹ Pa |
| Compliance | ASTM D4065, ISO 6721, ISO 11357-2, USP <1031>, FDA 21 CFR Part 11 (software-enabled) |
| Brand | Metravib |
|---|---|
| Origin | France |
| Model | VHF104 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −50 to 110 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–10 °C/min |
| Frequency Range | 100–10,000 Hz |
| Force Range | ±150 N |
| Displacement Range | ±10,000 µm |
| Strain Range | 10⁻⁶–30% |
| Deformation Modes | Tension, Compression, Annular Shear |
| Standard Masses | 5, 10, 20, 40, 80, 200 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861e |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Tan δ Range | 0.0001–100 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA1 |
| Temperature Range | −190 °C to 600 °C |
| Force Range | ±0.001 N to ±10 N |
| Displacement Range | ±1 mm |
| Frequency Range | 0.001 Hz to 300 Hz |
| Stiffness Range | 50 N/m to 10⁵ N/m |
| Tan δ Range | 0.0001 to 50 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DP70 / DP90 |
| Temperature Range | RT to 400 °C (DP70), –20 to 400 °C (DP90) |
| Accuracy | ±0.4 °C (–20 to 30 °C), ±0.2 °C (30 to 200 °C), ±0.5 °C (200 °C to max) |
| Heating Rate | 0.1–20 °C/min |
| Compliance | ASTM D3104, D3461, D36, D6089 |
| Data Output | PDF, CSV, video export, LIMS-compatible CSV |
| Sample Carrier | Standardized disposable cups per ASTM/DIN/Ph. Eur. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 1 |
| Temperature Range | –150 °C to 700 °C |
| Sensor Configuration | 56- or 120-pair star-arranged thermocouples |
| Optional Modules | UV-DSC, HP-DSC (up to 100 bar / down to 10 mbar), DSC-Microscopy System |
| Autosampler Capacity | Up to 34 samples |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 Excellence Series |
| Temperature Range | −150 °C to 700 °C |
| Data Acquisition Rate | Up to 50 data points per second |
| Sensor Type | MultiSTARe™ DSC sensor with 56 or 120 thermocouple pairs (Au/Au-Pd) |
| Cooling Rate | 0.02 K/min to 50 K/min |
| Calibration | FlexCal® (fully automated, multi-point, reference-based) |
| Compliance | Designed for GLP/GMP environments |