Thickness Gauge
Filter
Showing 91–120 of 254 results
| Brand | Fangyuan Instruments |
|---|---|
| Origin | Guangdong, China |
| Model | DR9000 |
| Measurement Principles | Magnetic Induction (for Fe substrates) & Eddy Current (for non-Fe substrates) |
| Measurement Range | 0–1250 µm (Fe), 0–1250 µm (non-Fe) |
| Resolution | 0.1 µm (≤100 µm), 1 µm (>100 µm) |
| Accuracy | ±(1–3)% of reading or ±2 µm (whichever is greater) |
| Substrate Compatibility | Ferrous (steel, iron) and non-ferrous (aluminum, stainless steel, copper, zinc, brass) |
| Display | 2.4" TFT LCD with backlight |
| Data Storage | Up to 10,000 readings (grouped by batch ID) |
| Interface | USB-C for data export |
| Compliance | ISO 2178, ISO 2360, ASTM B499, ASTM D7091, DIN EN ISO 1461 |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | Filmetrics (a KLA company) |
| Type | Benchtop Spectroscopic Reflectometry System |
| Model | F3-sX |
| Wavelength Options | 980 nm / 1310 nm / 1550 nm |
| Thickness Range | 15 nm – 3 mm (depending on configuration and film type) |
| Spot Size | 10 µm |
| Material Library | >130 preloaded optical constants |
| Software | FILMeasure 8 (local acquisition & analysis), FILMeasure Standalone (remote data processing) |
| Compliance | Designed for semiconductor fab, R&D, and QC environments supporting GLP/GMP traceability workflows |
| Brand | KLA |
|---|---|
| Origin | USA |
| Model | Filmetrics F50 |
| Measurement Principle | Broadband Spectral Reflectometry |
| Maximum Sample Diameter | 450 mm |
| Stage Type | Motorized R-Theta Platform |
| Scan Patterns | Polar, Rectangular, Linear, and User-Defined |
| Wavelength Options | UV–NIR (model-dependent, e.g., F50-UV: 190–1100 nm |
| F50-NIR | 900–1700 nm) |
| Measurement Speed | Up to 2 points per second |
| Predefined Scan Templates | >30 built-in |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, supports audit-ready data logging per FDA 21 CFR Part 11 requirements when integrated with validated software configuration |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | CMS2/STEP |
| Measurement Principle | Coulometric (Anodic Dissolution) per DIN EN ISO 2177 & ASTM B764-94 |
| Application Scope | Single/Multi-layer Metallic Coatings on Conductive or Non-conductive Substrates (e.g., Fe, Cu, ABS, PCB) |
| Thickness Range | 0.05–50 µm |
| Electrolytic Rate Selection | 0.1–10 µm/min |
| Measured Area | 0.6–3.2 mm² (via interchangeable O-rings) |
| STEP Function | Simultaneous Thickness & Potential Difference Measurement (Ni multilayer systems) |
| Display | High-resolution color LCD |
| Software Features | Graphical voltage curve display, statistical analysis, multi-language UI, configurable units |
| Compliance | DIN EN ISO 2177, ASTM B764-94, DIN 50022 |
| Accessories | V18 semi-automated stand with spherical support & rotating sample plate, 3-position electrolyte bottle holder (100 mL each) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | MP10E |
| Measurement Principle | Electromagnetic Induction (DIN EN ISO 2178, ASTM B499) |
| Display | 60 × 30 mm LCD, dual-line alphanumeric (16 characters per line) |
| Probe Interface | Plug-in connector supporting up to 30 probe types (E- and VxE-series, e.g., EGAB1.3) |
| Auto-Probe Recognition | Yes |
| Data Storage | None |
| Connectivity | None |
| Power Supply | Replaceable or rechargeable batteries |
| Compliance | DIN EN ISO 2178, ASTM B499 |
| Included Accessories | Protective cap, carrying case, batteries, operating manual |
| Excluded | Probes, calibration standards |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fischerscope PMP10 |
| Pricing | Available Upon Request |
| Measurement Principle | Phase-Sensitive Eddy Current Method |
| Compliance | DIN EN ISO 21968 |
| Standard Probe Frequencies | 60 kHz, 240 kHz, 1.25 MHz |
| Software | FISCHER DataCenter (PC-based, supports data transfer, statistical analysis, graphical evaluation, and report generation) |
| Probe Options | ESD20Cu (for planar PCB copper), ESL080 (for through-hole copper plating), ESD20ZN/ESD2.4/ESD20NI (for Zn/Ni on steel) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XAN500 |
| Detector Type | Silicon Drift Detector (SDD) |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Portability | Handheld & Benchtop-Convertible Configuration |
| Compliance | CE, RoHS, ISO 3497, ASTM B568, DIN EN ISO 3497, ISO 2178 (for magnetic substrates), ISO 2360 (for non-magnetic substrates) |
| Software | WinFTM® v8.x with GLP/GMP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Price Range | USD 25,000 – 65,000 (FOB Hamburg) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FMP10 |
| Price Range | USD 27,000 – 68,000 |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FMP10–FMP40 |
| Measurement Principles | Magnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous conductive substrates) |
| Compliance Modes | IMO PSPC, SSPC-PA2, QUALANOD, QUALICOAT |
| Memory Capacity | Thousands of measurement records |
| Probe Interface | Interchangeable probe system |
| Operating Principle | Dual-method substrate-agnostic thickness quantification via calibrated electromagnetic field perturbation analysis |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FMP100 / FMP150 |
| Measurement Principle | Magnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous substrates) |
| Operating System | Windows CE |
| Display | High-Resolution Graphical Touchscreen |
| Onboard Memory | Supports >10,000 measurements |
| Compliance Modes | IMO PSPC, SSPC-PA2, QUALANOD, QUALICOAT |
| Probe Interface | Interchangeable probe design |
| Data Management | Compatible with DataCenter IP inspection planning software |
| Regulatory Context | Designed for GLP/GMP-aligned workflows |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMSPC-2 |
| Price Range | USD 28,000 – 70,000 |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | MP0/MP0R |
| Measurement Principle | Dual-mode electromagnetic induction (for ferrous substrates) and eddy current (for non-ferrous substrates) |
| Display | Dual independent pivotable LCD screens with backlight |
| Housing | IP65-rated ruggedized enclosure |
| Probe | Wear-resistant integrated probe |
| Compliance Modes | IMO PSPC, SSPC-PA2 |
| Operating Temperature | −10 °C to +50 °C |
| Battery Life | Up to 30,000 measurements per charge (standard alkaline AA batteries) |
| Data Output | USB interface for PC transfer |
| Calibration | Factory-calibrated with traceable NIST-equivalent reference standards |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PCB200 |
| Price Range | USD 68,000 – 136,000 |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | PMP10 |
| Measurement Principle | Phase-Sensitive Eddy Current |
| Operating Frequencies | 60 kHz / 240 kHz / 1.25 MHz |
| Probe Compatibility | ESD20Cu, ESD20Ni, ESD20Zn, ESD2.4, ESL080 |
| Max Data Storage | 20,000 measurements across 4,000 data groups |
| Applications | 100 user-defined programs |
| Display Resolution | 3-level precision |
| Measurement Modes | Automatic, Continuous, External Trigger |
| Analysis Modes | Scientific, Statistical, Limit (Hi/Lo), Analog Simulation |
| Security | Password protection & key lock |
| Power Management | Auto-off |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fischer PHASCOPE PMP10 |
| Price | Upon Request |
| Measurement Principle | Phase-Sensitive Eddy Current |
| Compliance | DIN EN ISO 21968 |
| Probe Options | ESD20Cu (60/240 kHz), ESL080 (via-hole Cu), ESD20Ni, ESD20Zn, ESD2.4 |
| Software | FISCHER DataCenter v5.x |
| Data Capacity | 20,000 measurements, 4,000 data sets, 100 application configurations |
| Display Resolution | 3-level precision |
| Operating Modes | Manual, Continuous, External Trigger |
| Analysis Modes | Scientific, Statistical, Limit Check, Analog Simulation |
| Security | Password Protection, Keypad Lock |
| Power Management | Auto-Shutdown |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Models | PMP10, RMP30-S, MPO, FMP |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMP10 |
| Pricing | Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | RMP30-S |
| Measurement Principle | Micro-resistive Method per EN 14571:2004 |
| Display | Dual-line, 16-character LCD (2 × 16) |
| Memory Capacity | Up to 100 application setups |
| Data Storage | Up to 10,000 measurements across 1,000 data blocks with timestamp (date/time stamping) |
| Interface | Bidirectional RS232 port |
| Probe Recognition | Automatic probe identification |
| Audio Feedback | Audible limit alarm |
| Statistical Functions | Mean, Std. Dev., Min/Max, Cp/Cpk, histogram generation |
| Compatible Probes | ERCU-N, ERCU-D10 |
| Power Supply | Rechargeable battery or AC adapter |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FISCHERSCOPE X-RAY Series |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fischer X-RAY XULM |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDL-B Series |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| X-ray Tube Voltage | Adjustable up to 50 kV |
| Collimator Options | 0.3 mm Ø standard |
| Measurement Chamber Dimensions (H×W×D) | 650 × 570 × 740 mm |
| Chamber Internal Dimensions (H×W×D) | 300 × 460 × 500 mm |
| Mass | ~105 kg |
| Viewing System | Integrated color CCD camera with real-time zoom and focus control |
| Distance Control Method | DCM (Distance Correction Method) for automated spectral intensity compensation across 3 fixed source-to-sample distances (standard: mid-position) |
| Sample Height Adjustment | Fixed-height X-ray head with removable support plate for oversized parts |
| Interface | RS-232, Ethernet-ready for remote command control |
| Software Platform | Native Win32 application for Windows 2000/XP |
| Language Support | English, German, French, Italian, Spanish, Chinese |
| Reporting & SPC | Embedded statistical engine with SPC charts, probability plots, histogram analysis, and customizable report generation including annotated sample images |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDLM Series |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| X-Ray Tube | Microfocus, adjustable high voltage (30/40/50 kV) |
| Collimator Set | Circular (0.1 / 0.2 / 0.3 mm) and rectangular (0.05 × 0.3 mm) |
| Sample Chamber Dimensions (W×D×H) | 570 × 740 × 650 mm |
| Internal Chamber Volume (W×D×H) | 460 × 500 × 300 mm |
| Z-Axis Travel Range | 144 mm (motorized) |
| Camera System | Integrated color CCD camera with live imaging and on-screen crosshair overlay |
| Beam Spot Visualization | Real-time X-ray beam size indicator synchronized with focal distance |
| Distance Correction Method | DCM (Distance Control Measurement), effective up to 80 mm |
| Software Platform | WinFTM® v6 (Windows-based, 32-bit), multilingual UI (EN/DE/FR/IT/ES/ZH) |
| Data Interface | RS-232, Ethernet-compatible remote command protocol |
| Reporting & SPC | Embedded statistical engine with control charts (X̄/R, X̄/S), probability plots, histogram analysis, and customizable PDF/Excel report generation |
| Regulatory Support | Audit trail, user access levels, electronic signature readiness per FDA 21 CFR Part 11 and GLP/GMP requirements |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | Fischer XDLM-PCB 200 / 210 / 220 |
| Price Range | USD 70,000 – 140,000 |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XUL Series |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| X-ray Tube Voltage | Adjustable to 30 kV / 40 kV / 50 kV |
| Collimator Options | Ø0.3 mm circular or 0.05 × 0.3 mm rectangular (optional) |
| Sample Chamber Dimensions (W×D×H) | 455 × 580 × 510 mm |
| Internal Chamber Dimensions (W×D×H) | 360 × 380 × 240 mm |
| Manual X-Y Stage Travel | 50 mm (X) × 50 mm (Y) |
| Imaging System | Integrated color CCD camera with real-time magnified view and auto-focus |
| Beam Indicator | On-screen X-ray beam size overlay synchronized with focal distance |
| Software Platform | WinFTM® v6 (base) or Super WinFTM® (optional, order no. 602-950) |
| Language Support | English, German, French, Italian, Spanish, Chinese |
| Reporting | Graphical reports with embedded sample images, SPC charts, probability plots, histogram analysis |
| Regulatory Readiness | Supports GLP/GMP documentation workflows |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XULM Series |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| X-Ray Tube | Microfocus, adjustable high voltage (30/40/50 kV) |
| Collimator Options | Ø0.1 mm / Ø0.2 mm circular |
| Sample Chamber Dimensions (W×D×H) | 375 × 580 × 480 mm |
| Internal Chamber Dimensions (W×D×H) | 360 × 460 × 240 mm |
| Manual X-Y Stage Travel | 50 mm (X) × 50 mm (Y) |
| Stage Platform Size | 360 × 240 mm |
| Viewing System | Integrated color CCD camera with real-time zoom and auto-focus |
| Beam Alignment | On-screen calibrated crosshair + dynamic X-ray beam size indicator |
| Software Platform | WinFTM® v6 (Win32 native, multilingual UI) |
| Reporting | Embedded sample image capture, SPC charts (X̄/R, X̄/S), probability plots, histogram analysis |
| Regulatory Support | Audit trail, user access levels, electronic signature readiness per FDA 21 CFR Part 11 & GLP/GMP requirements |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MMS PC2 BU |
| Price Range | USD 27,000 – 68,000 (based on configuration and probe selection) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMS PC2 |
| Pricing | Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | MMS PC2 |
| Operating System | Windows CE |
| Connectivity | LAN, USB |
| Measurement Principles | Eddy Current (amplitude & phase-sensitive), Magnetic Induction, Beta Backscatter, X-ray Fluorescence (via optional modules) |
| Supported Properties | Coating thickness (non-conductive on non-ferrous, non-conductive on ferrous, conductive on non-ferrous), Ferrite content in austenitic steels, Electrical conductivity of non-ferrous metals |
| Compliance | ISO 2178, ISO 2360, ASTM B244, ASTM B536, DIN 50981, DIN 50982, EN ISO 2178, EN ISO 2360 |
| Data Management | Onboard storage, CSV export, GLP-compliant audit trail (via software), FDA 21 CFR Part 11 ready (with validated software package) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADLM-PCB |
| Pricing | Available Upon Request |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDL |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Elemental Range | Cl (Z=17) to U (Z=92) |
| Sample Positioning Options | Fixed or Motorized X/Y/Z Stages (XDL 210–240 variants) |
| Collimator Options | Circular or Rectangular |
| Detector Type | Proportional Counter |
| Measurement Distance | 0–80 mm |
| DCM Technology | Patented Distance Compensation Method |
| Camera System | High-Resolution CCD Color Imaging |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Weight | 100–120 kg |
| Compliance | Designed for ISO 3497, ASTM B568, DIN 50987, and EN ISO 3497-compliant measurement workflows |
| Software | FISCHER WinFTM® v8+ with GLP/GMP audit trail, 21 CFR Part 11 optional modules |