Thickness Gauge
Filter
Showing 121–150 of 254 results
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDLM |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Sample Positioning | Motorized Z-axis (standard) |
| Collimators | 4 interchangeable (diameters: 0.1, 0.2, 0.3, 0.5 mm) |
| Primary Filters | 3 interchangeable Al, Cu, Ti |
| Detector | Proportional counter with high-count-rate capability |
| Measurement Distance | 0–80 mm (adjustable via motorized Z-axis) |
| Optical Alignment | Integrated high-resolution color CCD camera with 10× digital zoom |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Instrument Weight | 100–120 kg |
| PC Interface | PCI/PCIe expansion slot required for spectrometer control and data acquisition |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDLM-PCB 220 |
| X-ray Tube | Tungsten anode microfocus tube with beryllium window |
| Tube Voltage | 3 adjustable high-voltage settings (up to 50 kV) |
| Detector | Proportional counter detector |
| Collimators | Motorized, multiple interchangeable apertures |
| Primary Filters | 3 motorized basic filters |
| Sample Stage | Motorized XYZ stage with programmable XY positioning and pop-up function |
| Optical Alignment | High-resolution color camera + laser pointer for precise targeting |
| Measurement Geometry | Horizontal sample chamber with bottom-access gap for large PCBs |
| Analysis Method | Fundamental Parameters (FP) quantification without calibration standards |
| Compliance | Designed for ISO 3497, ASTM B568, IPC-4552A, and RoHS/WEEE screening workflows |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XUL220 |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Detector Type | Proportional Counter |
| Count Rate Capability | High |
| Imaging System | High-Resolution Color CCD Camera with Manual Focus and Adjustable LED Illumination |
| Sample Chamber Dimensions | Extra-Large (Enabling Large-Part Measurement) |
| Stage | Manual XY Translation Stage |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (Non-Condensing) |
| Compliance | Designed for ISO 3497, ASTM B568, DIN 50982, and RoHS/WEEE Screening Applications |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XULM |
| Detector Type | Proportional Counter |
| Optical System | High-Resolution CCD Color Camera with Manual Focus |
| Collimators | 4 Switchable (e.g., 0.1 mm, 0.2 mm, 0.3 mm, 0.5 mm) |
| Primary Filters | 3 Switchable |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Form Factor | Benchtop with Manual XY Stage |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDVM-W |
| Measurement Principle | X-ray fluorescence (XRF) |
| Standards Compliance | DIN 50987, ISO 3497, ASTM B568 |
| Cabinet Dimensions (H×W×D) | 720 × 660 × 950 mm |
| Weight | ~135 kg |
| Internal Chamber (H×W×D) | 160 × 560 × 530 mm |
| X-ray Tube | Adjustable high voltage (30/40/50 kV), current up to 0.8 mA |
| Detector | Xenon-filled proportional counter with 4096-channel ADC (displayed as 256-channel spectrum) |
| Collimator Options | Standard Set I (0.1 mm, 0.2 mm, 0.05×0.05 mm², 0.03×0.2 mm² slot), optional Sets II & III |
| XY Stage Travel | 250 × 250 mm (XDVM-W standard configuration) |
| Z-axis Travel | 145 mm |
| Camera | High-resolution color CCD with dual magnification (×40 / ×80), crosshair + metric grid + spot size indicator |
| Software Platform | Native Win32 application for Windows 2000 and later |
| Language Support | English, German, French, Italian, Spanish, Chinese, Japanese |
| Data Interface | RS-232 serial port, remote command control via script files or network environment |
| Calibration | Automated beam centering, “Application Toolbox” with calibration standards and parameter disk |
| Reporting | User-defined report editor with embedded images (BMP), company logos, charts, font selection |
| Statistical Tools | SPC charts, probability plots, histogram analysis |
| Security | Customizable “short menu” lockout for critical system functions |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Excitation Source | Micro-focus Tungsten X-ray Tube with Beryllium Window |
| Adjustable Tube Voltage | 3 kV / 15 kV / 50 kV |
| Filter Options | 6 interchangeable primary filters |
| Collimators | Motorized, switchable |
| Elemental Range | Al (13) to U (92), up to 24 elements simultaneously quantifiable |
| Sample Stage | Motorized, programmable X/Y translation stage + motorized Z-axis lift |
| Safety | Interlocked top-hinged measurement door with automatic sample-stage egress |
| Imaging System | Integrated high-resolution video camera with 10× digital zoom, crosshair overlay, and real-time positioning feedback |
| Software Platform | WinFTM® v8.x (compliant with ISO 3497, ASTM B568, DIN 50981, and EN ISO 3497 for coating thickness measurement) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDV-μ |
| Excitation Optics | Polycapillary X-ray Lens System |
| Detector | Silicon Drift Detector (SDD) |
| Elemental Range | Al (13) to U (92) |
| Max. Simultaneous Elements | 24 |
| Sample Stage | Motorized X/Y Table + Motorized Z-axis Lift |
| Filtration | 4 Switchable Primary Filters |
| High Voltage | 3 Adjustable kV Settings |
| Software | WinFTM® |
| Compliance | ISO 3497, ASTM B568, DIN EN ISO 3497, RoHS/WEEE Directive Support |
| Optional Accessories | Large-area PCB Stage, Custom Collimators |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | XDVM-u |
| Measurement Principle | X-ray Fluorescence (XRF) |
| Compliance | DIN 50987, ISO 3497, ASTM B568 |
| Max. Measurable Layers | 23 |
| Elements Analyzed | Cl (Z=17) to U (Z=92) |
| Element Quantification Range | x ppm to 100% |
| Spectral Channels | 1024 (raw: 4096) |
| Minimum Spot Size | 50 × 100 µm |
| Focal Depth Range | 2.5 mm |
| X-ray Tube | Adjustable HV (30/40/50 kV), Current up to 0.8 mA |
| Detector | Peltier-cooled semiconductor with high energy resolution |
| XY Stage Travel | X=250 mm, Y=220 mm, Positioning Accuracy: ±0.005 mm |
| Z-Axis Travel | 95 mm |
| Camera Magnification | 30×–1108× with crosshair & scale grid |
| Software | WinFTM® V6 with PDM (Product Data Management) |
| Interface | RS232, Ethernet, removable storage |
| Languages | English, German, French, Italian, Spanish, Chinese |
| Origin | Greece |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FR-pOrtable |
| Pricing | Upon Request |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SGC-10 |
| Price | USD 14,000 (FOB Tianjin) |
| Thickness Range | 20 nm – 50 µm (thickness only) |
| Accuracy | <1 nm or <0.5% |
| Repeatability | 0.1 nm |
| Wavelength Range | 380–1000 nm |
| Max. Layers | 4 |
| Minimum Spot Diameter | 1.2 mm |
| Adjustable Spot Size | 1.2–10 mm |
| Sample Stage | 290 × 160 mm |
| Light Source | Long-life tungsten-halogen lamp (2000 h lifetime) |
| Optical Fiber | Fused silica broadband fiber |
| Detector | Imported fiber-coupled spectrometer |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Dimensions | 300 × 300 × 350 mm |
| Weight | 18 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GH-D |
| Price | Upon Request |
| Measurement Range | 0–5 mm |
| Resolution | 0.1 µm |
| Sample Feed Interval | 0–1000 mm |
| Measurement Points per Scan | 1–10 |
| Display | LCD with Real-Time Statistical Output (Max/Min/Avg/Current) |
| Interface | RS-232 or USB for PC Connectivity |
| Operating Mode | Manual & Motorized Auto-Scan |
| Data Export | CSV, TXT, or via Optional GBPI ThicknessMaster™ Software |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Strata920 |
| Price Range | USD 68,000 – 136,000 |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG-02 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (±2 mm tolerance) |
| Operating Temperature | 0°C to 45°C |
| IP Rating | IP65 |
| Sample Surface Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminum (polished & EDT), ZnMg-coated, aluzinc |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, and other organic lubricants (with custom calibration) |
| Power Supply | Internal rechargeable battery (≥12 h operation) |
| Data Documentation | Integrated photo-capture via smartphone interface |
| Auto-validation | Onboard self-check and drift compensation |
| Rolling Direction Detection | Real-time automatic recognition |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG02 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Power Supply | Internal rechargeable battery (≥12 h runtime) |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed, Al, ZnMg, aluzinc |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, waxes, hot-melt adhesives, and other organics (with custom calibration) |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG03 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Standoff Distance | 8 mm (+5/−2 mm) |
| Operating Temperature | 0–45 °C |
| IP Rating | IP65 |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), Al, ZnMg, aluzinc |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG1 |
| Measurement Principle | Dual-Wavelength Near-Infrared Absorption Spectroscopy |
| Typical Measurement Range | 0.1–20 g/m² (oil equivalent on metal substrates) |
| Accuracy | ±0.05 g/m² (calibrated against reference standards) |
| Repeatability | <±0.02 g/m² |
| Response Time | <1 second per measurement |
| Power Supply | Rechargeable NiMH battery (included) |
| Interface | USB 2.0 with proprietary PC software |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |
| Operating Temperature | 10–40 °C |
| Weight | 0.85 kg (with battery) |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG1 / NG2 / NG3 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminum (polished & EDT), ZnMg-coated steel |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG2 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Power Supply | Internal rechargeable battery (≥12 h runtime) |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminized (Al, Al-Zn, ZnMg), bare and pre-treated surfaces |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, waxes, hot-melt adhesives, and other organic lubricants (with custom calibration) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NG2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Infralytic NG2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Infralytic NG2 |
| Pricing | Upon Request |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG2 / NG3 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminized (Al, ZnMg), bare aluminum (polished & EDT) |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Power | Battery-operated (≥12 h runtime) |
| Compliance | Designed for ISO/IEC 17025-aligned QA workflows, supports GLP/GMP audit trails via optional software logging |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NG2 / NG3 / NGO3 |
| Price Range | USD 68,000 – 136,000 |
| Measurement Principle | Quad-Wavelength Infrared Spectrophotometry |
| Measuring Range | 0.1–6 g/m² (oil), 0.1–10 g/m² (water) |
| Resolution | 0.1 mg/m² |
| Accuracy | ±10% (±5° angular tolerance) |
| Angular Drift Sensitivity | < 0.4% |
| Standoff Distance | 200 mm |
| Strip Height Tolerance | ±20 mm |
| Dimensions | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Operating Temperature | 0 °C to +55 °C |
| Measurement Frequency | ≤120 Hz |
| IP Rating | IP65 |
| Compatible Substrates | Ferrous & non-ferrous metals, ceramics |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| Surface Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated, aluzinc (ZnMg), bare aluminum, pre-treated substrates |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Operating Temperature | 0–45 °C |
| IP Rating | IP65 |
| Power Supply | Internal rechargeable battery (≥12 h operation) |
| Compliance | Designed for ISO/IEC 17025-aligned QA workflows, supports GLP/GMP traceability via timestamped digital logs |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO02 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| Operating Temperature | 0 °C to 45 °C |
| IP Rating | IP65 |
| Power Supply | Internal rechargeable battery (≥12 h runtime) |
| Sample Surface Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminum (polished & EDT-treated), ZnMg-alloy coated, bare or pre-treated substrates |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, and other organics (with custom calibration) |
| Compliance | Designed for ISO/IEC 17025-aligned QC environments |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO1/2/3 |
| Measurement Principle | Infrared Spectroscopy |
| Measurement Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | Up to 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| Operating Temperature | 0°C to 45°C |
| IP Rating | IP65 |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized, electrogalvanized, phosphated, annealed galvanized, aluminum (polished & EDT), ZnMg-coated, aluzinc |
| Lubricant Types | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Power | Battery-operated (≥12 h runtime) |
| Compliance | Designed for GLP/GMP-aligned production environments |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO3-W |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measuring Distance | 200 mm |
| Strip Height Tolerance | ±20 mm |
| Dimensions | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Operating Temperature | 0 °C to +55 °C |
| Measurement Frequency | ≤120 Hz |
| Substrate Compatibility | All metallic and ceramic strip materials |
| Output Units | g/m², mg/m² |
| Display Resolution | 0.1 mg/m² |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO3-W |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measuring Distance | 200 mm |
| Measurement Range | Water & Emulsion Residue (0.1–500 mg/m²) |
| Accuracy | ±5% of reading (typical, dependent on surface uniformity and substrate emissivity) |
| Repeatability | <±2 mg/m² |
| Sampling Frequency | Up to 120 Hz |
| Standoff Tolerance | ±20 mm vertical deviation |
| Operating Temperature | 0 °C to +55 °C |
| Enclosure Rating | IP65 |
| Dimensions (L×W×H) | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Substrate Compatibility | Ferrous & non-ferrous metals, ceramic-coated strips |
| Output Interface | Analog 4–20 mA, RS-485, Ethernet (Modbus TCP / optional OPC UA) |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGO3-WATER |
| Price Range | USD 65,000 – 130,000 |
| Brand | Jinhuatester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CHY-01 |
| Measurement Range | 0–5 mm (custom fixtures available) |
| Measurement Pressure | 17.5 ± 1 kPa (for films), 100 ± 1 kPa (for paper, optional fixture required) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode) |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions (W×D×H) | 454 × 352 × 500 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 30 kg |
| Interface | RS232 serial port |
| Standard Accessories | Main unit, calibration gauge blocks, thermal micro-printer |
| Optional Accessories | PC-based measurement software, RS232 communication cable, calibrated weight kits, automated multi-point sample feeder |