| Brand | Marzhauser |
|---|---|
| Origin | Germany |
| Model | SCAN IM |
| Travel Range | 30 mm to 300 mm (X/Y) |
| Compatibility | Upright, Inverted & Stereo Microscopes |
| Mounting Interface | Standard dovetail and screw-hole patterns per DIN/ISO microscope stage specifications |
| Drive Type | Stepper motor with closed-loop position verification |
| Positioning Resolution | ≤ 0.1 µm (dependent on controller and microstepping configuration) |
| Repeatability | ±0.5 µm |
| Load Capacity | Up to 1.5 kg (static, centered) |
| Environmental Rating | Designed for ISO Class 5–7 laboratory environments |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | Hamilton Thorne |
|---|---|
| Origin | USA |
| Model | XYClone |
| Laser Wavelength | 1480 nm (Infrared) |
| Laser Power | 300 mW (Class I) |
| Pulse Duration | 1–3000 µs adjustable |
| Laser Intensity | 1–100% adjustable |
| Objective Magnification | 20× or 40× |
| Imaging System | High-resolution color digital or monochrome analog camera |
| Software Functions | Zona pellucida thickness measurement, embryo/nucleus/laser-hole diameter quantification, statistical reporting, temperature-ring visualization (50–100 °C), image/video capture & export |
| Compatibility | Universal mounting for inverted microscopes |
| Brand | Prior |
|---|---|
| Origin | United Kingdom |
| Model | OpenStand® |
| Type | Motorized Electrophysiology-Compatible Optical Platform |
| Z-Axis Travel | 100 mm |
| Throat Depth | 200 mm |
| Condenser Adjustment Range | 35 mm |
| Brand | Norpix |
|---|---|
| Origin | Canada |
| Model | StreamPix |
| Interface Compatibility | GigE Vision, USB3 Vision, 10/25 GigE, Camera Link, CoaXPress |
| Camera & Frame Grabber Support | >200 manufacturers (via native SDKs and APIs) |
| Multi-Computer Synchronization | Yes (hardware- and software-triggered exposure sync across distributed systems) |
| External Signal Integration | TTL, analog, and digital I/O for synchronized acquisition with ECG, EEG, temperature, pressure, or other physiological sensors |
| Trigger Modes | Pre-trigger, post-trigger, and loop-buffer recording with IR/NIR camera support |
| Remote Control | HTTP/HTTPS-based web interface (RESTful endpoints) |
| Operating System | Windows 10/11 (64-bit), Windows Server 2019/2022 |
| Brand | Cairn |
|---|---|
| Origin | United Kingdom |
| Model | OPENFRAME |
| Category | Fluorescence Stereo Microscope |
| Compatibility | Nikon & Olympus Infinity-Corrected Objectives |
| Control Software | Micro-Manager (Open Source) |
| Structural Architecture | Industrial-Grade Rack-and-Pinion Mounts on All Ports |
| Optical Access | Direct, Unobstructed Path to Objective Back Focal Plane |
| Serviceability | Field-Serviceable by Trained Microscopists |
| Calibration Kit | Integrated Laser Pointer Test Suite for Optical Alignment Verification |
| Expandability | Component-Level Procurement (No Bundling Required) |
| Interoperability | Compatible with Third-Party Light Sources, sCMOS/EMCCD Cameras, Motorized Stages, Filter Wheels, Tube Lenses, and Dichroics |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −196 °C to +600 °C |
| Temperature Stability | < 0.01 °C |
| Temperature Resolution | 0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X/Y Translation Range | 16 mm |
| Heating Zone Diameter | 22 mm |
| Window Thickness (Cover Slip) | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Kissei |
|---|---|
| Origin | Japan |
| Model | SleepSign |
| Device Type | Electrophysiological Sleep Stage Monitoring and Closed-Loop Deprivation System |
| Regulatory Classification | Research-Use-Only (RUO) Instrument for Preclinical Neuroscience |
| Brand | PRIME TECH |
|---|---|
| Origin | Japan |
| Model | PIEZO PMM6 |
| Drive Unit Options | MB-D-2 (Medium Output) / MB-U-2 (High Output) |
| Minimum Positioning Resolution | 0.1 µm |
| Touchscreen Modes | 3 (STANDARD, Piezo-ICSI, EXPART) |
| Operational States | 6 (3 modes × 2 states) |
| Piezo Intensity Levels | 16-step adjustable (1, 1/2, 2/3 increments) |
| Speed Settings | 16-step adjustable |
| Onboard Program Storage | 8 (EXPART mode only) |
| Cleaning Function | Enabled in Piezo-ICSI & EXPART modes |
| Footswitch Configuration | Dual-pedal (PMM actuation + mode/state toggle) |
| Controller Dimensions | 132.5(W) × 280(L) × 210(H) mm, 3.5 kg |
| PMM Drive Unit Weight | 110 g (MB-D-2) / 200 g (MB-U-2) |
| Touchscreen Unit Dimensions | 105(W) × 145(L) × 38(H) mm, 600 g |
| Footswitch Dimensions | 132.5(W) × 110(L) × 35(H) mm, 620 g |
| Power Supply | AC 100–240 V (±10%), 50/60 Hz, 30 VA |
| Operating Environment | 0–40 °C, ≤85% RH (non-condensing) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS350V |
| Temperature Range | −196 °C to +350 °C (with LN₂ cooling) |
| Vacuum Range | Down to 10⁻³ mbar |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | < ±0.1 °C |
| Sensor | 100 Ω Pt RTD |
| Sample Area | Ø22 mm |
| XY Translation Range | 16 mm |
| Optical Aperture | Ø1.3 mm |
| Brand | Prior |
|---|---|
| Origin | United Kingdom |
| Model | PLW20 |
| Capacity | 20 microplates (2 racks × 10) |
| Motion Axes | 3 independently controlled and encoded axes (X, Y, Z/rotation) |
| Plate Height Compatibility | Up to 19 mm (with or without lid) |
| Construction | Stainless steel rack assembly |
| Controller Compatibility | ProScan II, ProScan III, and Focus Controllers via DLL interface |
| Safety & Sensing | Integrated plate presence detection sensors |
| Microscope Integration | Designed for inverted microscopes |
| Compliance | Compatible with GLP/GMP workflows requiring audit-trail-capable automation |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | RH95 |
| Compatible Stages | THMSG600, MFS, LTS420, HFS600 |
| Max Controlled Volume | 2000 cm³ |
| RH Range | 5–90% RH |
| RH Stability | ±0.5% RH at setpoint |
| RH Ramp Rate | ~7% RH/min |
| Sensor Response Time | ~8 s |
| Sensor Type | Integrated Digital Capacitive T/RH Sensor |
| Inert Gas Input | Up to 5 bar (optional regulator module) |
| Brand | Chroma |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Component |
| Model Series | Chroma |
| Price Range | USD 1,400 – 7,000 (based on configuration) |
| Component Type | Precision Interference Optical Filter |
| Brand | Prior |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Queensgate OP400 / NanoScan SP |
| Component Category | Optical Positioning Actuators |
| Travel Range | 400 nm / 600 nm |
| Resolution | Sub-nanometer (via integrated capacitive sensing) |
| Load Capacity | Up to 500 g |
| Settling Time | Optimized for high-speed z-stacking |
| Compatibility | Prior, Nikon, Olympus, Zeiss, Leica, Okolabs, Tokai Hit microscopes |
| Controller | Queensgate NPC Series |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Optical Component |
| Model | UIS2 |
| Component Type | Optical Element |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | DIPP-Macro II |
| Instrument Type | Static Image Analysis System |
| Compliance | ASTM E2457, ISO 13322-1, USP <429> (Image Analysis) |
| Data Output Formats | CSV, TIFF, AVI, PNG, PDF |
| Software Architecture | Windows 64-bit (Windows 10/11), GPU-accelerated processing |
| License Type | Perpetual node-locked or floating license |
| Regulatory Support | Audit trail, user access control, electronic signature readiness (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | HAS-DX |
| Resolution | 1920 × 1080 (Full HD, 2 MP) |
| Maximum Frame Rate | 100,000 fps (at reduced ROI) |
| Standard Frame Rate | 2,000 fps (at full resolution) |
| Interface | USB 3.0 |
| Pixel Size | 5.86 µm |
| Sensor Type | Global Shutter CMOS |
| Compliance | CE, RoHS |
| Operating System Support | Windows 10/11 (64-bit), Linux (SDK available) |
| Brand | Teledyne Lumenera |
|---|---|
| Origin | Canada |
| Model | INFINITY |
| Image Resolution | 2752 × 2192 |
| Pixel Size | 6.5 µm |
| Sensor Format | 1″ |
| Frame Rate | 27 fps |
| Dynamic Range | 16-bit |
| Quantum Efficiency | 95% |
| Interface | USB 3.1 |
| Monochrome/Color | Selectable |
| Key | Brand: Marzhauser |
|---|---|
| Origin | Germany |
| Model | Liquid Dispenser |
| Delivery Principle | Pressure-driven dispensing |
| Volume Control | Time-programmable |
| Max Reservoir Capacity | 100 mL (interchangeable borosilicate glass reservoir) |
| Fluid Path Material | Chemically inert PTFE capillary tubing |
| Compatibility | Custom lens adapters for oil-immersion and water-immersion objectives |
| Actuation Modes | Manual, USB 2.0 (Type-B), TTL trigger, TANGO controller interface (5-pin female), remote control port (7-pin female) |
| Weight | 1.5 kg |
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Model | Visoria M |
| Optical Configuration | Encoded, Motorized Illumination Control |
| Observation Modes | Brightfield, Darkfield, Polarized Light, Differential Interference Contrast (DIC), Oblique Illumination, Fluorescence (optional) |
| Macro Objective | Optional 0.7× Objective (FOV ≈ 36 mm) |
| Software Platform | Enersight |
| Compliance | Designed for ISO/IEC 17025-compliant labs, supports audit-trail–enabled workflows per GLP/GMP requirements |
| Imaging Interface | Integrated tablet display (no PC required), HDMI output |
| Ergonomics | Adjustable height stand, tilting monitor arm, low-fatigue observation posture |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | MMO-203 / MMO-4 / UMM-3FC |
| Component Type | Precision Optical Manipulation Assembly |
| Positioning Resolution | 1 µm (MMO-203), Continuous Fine/Coarse Dual-Stage Control (UMM-3FC) |
| Actuation Method | Manual Mechanical Drive with Ergonomic Knob or Joystick Interface |
| Sample Interaction Modes | Electrostatic Pickup, Pneumatic Aspiration/Dispensing, Mechanical Dissection & Retrieval |
| Brand | KISSEI |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Kinema Tracer |
| Pricing | Upon Request |
| Brand | Cairn |
|---|---|
| Origin | United Kingdom |
| Model | Optosplit |
| Component Type | Optical Beam-Splitting Assembly |
| Wavelength Separation | Dual-band, adjustable via rotating dichroic prism |
| Spatial Registration | Precise co-aligned imaging via fixed optical path difference |
| Field Selection | Optional variable-field iris for ROI definition and inter-channel crosstalk suppression |
| Compliance | Designed for integration into ISO 17025-compliant microscopy workflows |
| Interface | Standard C-mount and SM1-threaded optical mounts |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Image-Pro |
| Price Range | USD 25,000 – 62,500 (based on configuration and modules) |
| Brand | Rofin |
|---|---|
| Origin | Australia |
| Model | PL550XL |
| Lamp Type | 500 W Xenon Arc |
| Input Voltage | 85–265 VAC, 50–60 Hz auto-sensing |
| Optical Output | UV–Visible Liquid Light Guide (2 m standard), optional IR Liquid Light Guide (2 m) with IR bandpass filters (>610 nm, >715 nm, >780 nm, >830 nm) |
| Wavelength Selection | Blank, White, 350 nm, 415 nm, 450 nm, 470 nm, 490 nm, 505 nm, 530 nm, 555 nm, 590 nm, 620 nm, 650 nm |
| Power Settings | P1–P8 continuous |
| User Interface | Three rotary dials (wavelength, power, fine adjustment), LED display, three programmable memory buttons, intelligent standby/power button, integrated light guide mounting points |
| Cooling System | Microprocessor-controlled variable-speed fan |
| Compliance | Designed for forensic laboratory environments compliant with ISO/IEC 17025 documentation practices and compatible with GLP/GMP audit trail requirements in evidence handling workflows |
| Standard Accessories | Camera filter set (OG475, OG515, OG550, OG590), high-pass camera adapters, 52/58 mm & 49/58 mm step-up rings, amber/red/neutral/yellow protective eyewear |
Show next