Water Quality Analysis
Filter
Showing 1441–1470 of 3714 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LO-300 |
| Instrument Type | Online |
| Measurement Principle | Laser Circular Area Scanning Reflectometry |
| Accuracy | ≤2.0% FS |
| Detection Range | 0–10 ppm (as oil film coverage equivalent) |
| Flow Rate Compatibility | Up to 100 L/min |
| Detection Distance | 0.3–4.0 m (up to 6.0 m on still water) |
| IP Rating | IP66 |
| Operating Temperature | −10 to +50 °C |
| Power Supply | AC 100 V ±10%, 50/60 Hz, ≤100 VA |
| Dimensions | Ø185 × 547 mm (H) |
| Weight | ~11 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9520-10D |
| Cable Length | 1 m |
| Operating Temperature Range | 0–45 °C |
| IP Rating | IP67 (per electrode housing specification) |
| Compatible With | HORIBA DO meters (e.g., D-55, LAQUA DO series) |
| Electrode Type | Clark-type polarographic membrane electrode |
| Replacement Module | 7541 (for 9520-series) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-310 / OCMA-315 |
| Detection Method | Solvent Extraction + Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–200 mg/L (dynamic, single-range) |
| Sample Matrix | Freshwater, Seawater, Wastewater |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Extractant | OCMA-310 → S-316 (trichloroethylene substitute) |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OCMA-350 |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350 / OCMA-355 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameter | Oil Content (Hydrocarbon) |
| Measurement Principle | Infrared Absorption Spectrophotometry at ~3.4 µm |
| Solvent Compatibility | S-316 (perchlorotrifluoroethane) |
| Detection Range | 0–200 mg/L (water), 0–200 mg/kg (soil), Absorbance mode |
| Detection Limit | 0.1 ppm (as hydrocarbon) |
| Calibration | Automatic zero calibration post initialization |
| Optional Accessory | SR-305 Solvent Regenerator |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Covered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL syringe, 25 µL syringe |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port & parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Weight | Approx. 8.5 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Optical Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C port & parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Sample Cell | 200-mm pathlength quartz cuvette |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-Dispersive Infrared (NDIR) Absorption |
| Extractant | S-316 (OCMA-350) / H-997 (OCMA-355) |
| Measurement Range | 0–200 mg/L, 0–1000 mg/kg, 0–1 Abs |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Detector Type | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C serial port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Sample Cell | 200 mm pathlength quartz cuvette |
| Minimum Detectable Concentration | 0.1 ppm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-350/355 |
| Detection Method | Non-dispersive Infrared (NDIR) Absorption |
| Extraction Solvent | OCMA-350 — S-316 |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Repeatability | ±0.4 mg/L ±1 digit (0–9.9 mg/L), ±2.0 mg/L ±1 digit (10.0–99.9 mg/L), ±4 mg/L ±1 digit (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Sensitivity | 1% of full-scale lower limit |
| Detector | Thermoelectric sensor |
| Display | Backlit LCD with timestamping |
| Interface | RS-232C port, parallel printer port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 mm (W) × 200 mm (H) × 285 mm (D) |
| Sample Cell | 200 mm pathlength quartz cuvette |
| Minimum Detection Limit | 0.1 ppm (as oil) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OCMA-355 |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Detection Limit | < 0.1 mg/L (as defined per ASTM D7066 and ISO 9377-2) |
| Accuracy | ±1 mg/L (at 10–100 mg/L range) |
| Resolution | 0.01 mg/L (0–99.9 mg/L) |
| Measurement Frequency | One analysis per 60 seconds (typical cycle time including extraction, separation, and quantification) |
| Solvent | S-316 (1,1,2-trichloro-1,2,2-trifluoroethane) |
| Sample-to-Solvent Ratio | 2:1 (v/v) |
| Data Storage Capacity | 300 measurement records with timestamp, operator ID, and calibration history |
| Compliance | Designed to meet EPA Method 1664A, ISO 9377-2, JIS K 0102, and supports GLP/GMP audit trails when paired with optional PC software |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-555 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extraction Solvent | S-316 (trichloroethylene-free, certified for oil-in-water analysis) |
| Sample Throughput | Fully automated extraction + NDIR quantification per cycle |
| Compliance | Designed to support EPA Method 1664A (modified), ISO 9377-2, and JIS K 0102 reference frameworks |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption after Solvent Extraction |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | S-316 (trichloroethylene-free chlorinated solvent) |
| Compliance | ASTM D7066, ISO 9377-2 (aligned), EPA Method 1664B (extraction protocol compatible) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Fluorometric Detection (S-316 solvent extraction followed by non-dispersive infrared absorption) |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B-aligned workflows |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | S-316 (trichloroethylene-free chlorinated solvent) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L |
| Resolution | 0.1 mg/L |
| Extraction Solvent | S-316 (Tetrachloroethylene) |
| Repeatability | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500 / OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction + Non-Dispersive Infrared (NDIR) Absorption |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging) |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±0.1 mg/L (at low range), ±4 mg/L (at 100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Sampling Frequency | 1 measurement per minute |
| Extractant | S-316 (OCMA-500) or H-997 (OCMA-505) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-500/505 & OCMA-550/555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared Absorption (NDIR) at ~3.4 µm |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs (absorbance) |
| Detection Limit | < 0.1 ppm (equivalent to < 0.1 mg/L) |
| Accuracy | ±0.2 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L) |
| Sampling Frequency | 1 measurement per 2 minutes (0.5 Hz) |
| Extractant Compatibility | S-316 or H-997 chlorinated solvents |
| Calibration | Automatic zero and span calibration (OCMA-500/505) |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption after Solvent Extraction |
| Measurement Range | 0–200 mg/L |
| Detection Limit | Not Specified |
| Accuracy | ±0.1 mg/L (0–99.9 mg/L) |
| Resolution | 0.1 mg/L (0–9.9 mg/L) |
| Measurement Cycle | One analysis per minute |
| Extractant | HORIBA H-997 solvent |
| Sample-to-Extractant Ratio | 2:1 (v/v) |
| Data Storage Capacity | 300 measurements |
| Display | 3.5-inch backlit color LCD |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 200 × 313 × 342 mm |
| Weight | 7 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extractant | HORIBA H-997 Solvent |
| Integrated Sample Extraction | Yes |
| Compliance | ASTM D7066, ISO 9377-2, EPA Method 1664 (compatible), GLP/GMP-ready data logging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 / OCMA-555 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging), 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1 mg/L |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 Solvent |
| Optional Accessory | SR-305 Solvent Regenerator |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Spectrophotometry (with solvent extraction and non-dispersive infrared detection) |
| Measurement Range | 0–200 mg/L (dynamic full-scale range) |
| Detection Method | Solvent extraction followed by non-dispersive infrared (NDIR) absorption analysis |
| Sample Matrix | Freshwater, seawater, and industrial wastewater |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Compatible Extraction Solvents | S-316 (for OCMA-550 configuration) or H-997 (for OCMA-555 configuration) |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column-based regeneration system) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, single-range), 0–1000 mg/kg, 0–1 Abs |
| Accuracy | ±1 mg/L (at 200 mg/L full scale) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Extractant | HORIBA H-997 solvent |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction Followed by Non-Dispersive Infrared (NDIR) Absorption |
| Measurement Range | 0–200 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±1% of reading or ±0.1 mg/L (whichever is greater) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 Solvent |
| Optional Accessory | SR-305 Solvent Regenerator |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 / OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic full-scale) |
| Accuracy | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Resolution | 0.1 mg/L |
| Extraction Solvent | HORIBA H-997 |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic full-scale) |
| Resolution | 0.1 mg/L |
| Detection Method | Solvent Extraction Followed by NDIR Absorption Analysis |
| Extractant for OCMA-505 | H-997 |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L), ±2 mg/L ±1 digit (10–100 mg/L), ±4 mg/L ±1 digit (100–200 mg/L) |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Solvent Extraction + Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–200 mg/L |
| Extractant | H-997 |
| Repeatability | ±0.2 mg/L (0–10 mg/L), ±2 mg/L (10–100 mg/L), ±4 mg/L (100–200 mg/L) |
| Compliance | Designed for ASTM D7066, ISO 9377-2, and EPA Method 1664B alignment |
| Optional Accessory | Solvent Regenerator SR-305 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (oil in water), 0–1000 mg/kg (oil in soil/sludge), 0–1 Abs (absorbance) |
| Accuracy | ±1 mg/L (at 10–100 mg/L range) |
| Resolution | 0.1 mg/L (0–99.9 mg/L), 1 mg/L (100–200 mg/L) |
| Repeatability | ±0.2 mg/L ±1 digit (0–10 mg/L) |
| Extractant | HORIBA H-997 solvent |
| Optional Accessory | Solvent Regenerator SR-305 (activated carbon + activated alumina column) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-505 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectrophotometry |
| Measurement Range | 0–200 mg/L (dynamic, auto-ranging), 0–1000 mg/kg, 0–1 Abs |
| Detection Limit | < 0.2 mg/L |
| Accuracy | ±1% of reading (mg/L) |
| Resolution | 0.1 mg/L (0–99.9 mg/L) |
| Sampling Frequency | 0.2 samples/min |
| Extractant | HORIBA H-997 solvent |
| Compliance | ASTM D7066, ISO 9377-2 (oil-in-water), EPA Method 1664 (modified), JIS K 0102 |