Water Quality Analysis
Filter
Showing 2911–2940 of 3694 results
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AquaChlor |
| Pricing | Upon Request |
| Measurement Principle | Amperometric Electrode (Gold Cathode / Silver Anode with Teflon Membrane) |
| Range | 0–5 ppm and 0–20 ppm |
| Resolution | 0.005 ppm |
| Accuracy | ±2% of reading or ±10 ppb, whichever is greater |
| Response Time (t₉₀) | 90 seconds |
| Units | ppm (Cl₂), °C / °F |
| Calibration | Single-point air calibration |
| Compensation | Automatic temperature compensation |
| Operating Temperature | 0–45 °C |
| Max Pressure | 15 PSIG (1.03 bar) at 40 °C |
| Flow Rate | 200–250 mL/min |
| Housing Material | Noryl |
| Electrode Materials | Gold cathode, silver anode |
| Selective Membrane | PTFE (Teflon®) |
| Communication Protocols | Modbus RTU, DeviceNet, USB, RS-232, CANopen |
| Data Interface | AV38 Local Display Unit or DataStick Network-Ready Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Aquakem 600 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Principle | Discrete Photometric Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem200 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | Up to 180 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Maximum Reagents per Test | 4 |
| Wavelength Range | 340–880 nm |
| Barcode Reader | Integrated |
| Sample Dilution | Auto pre-dilution and auto re-dilution |
| Cadmium Reduction Module | Optional (for nitrate analysis) |
| System Architecture | Open-platform, user-definable methods, reagents, and protocols |
| Probe Function | Dual-purpose pipetting probe with integrated mixing capability |
| Wash System | Automatic internal/external probe washing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem250 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | 250 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Maximum Reagents per Test | 4 |
| Cadmium Reduction Module | Optional |
| Barcode Reader | Integrated |
| Sample/Reagent Dispensing | Fully Automated with Internal/External Tip Washing |
| Dilution Capability | Auto Primary & Secondary Dilution |
| Stirring | Independent Stir Bars with Dedicated Wash Station |
| Reagent Flexibility | User-Defined Methods and Custom Reagent Preparation Supported |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | DO DataStick |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Ozone DataStick |
| Instrument Category | Online Analyzer |
| Measurement Principle | Polarographic Electrochemical Probe (Clark-type) |
| Range | 0–10 ppm |
| Accuracy | ±2% of reading |
| Resolution | 0.01 ppm |
| Response Time | t₉₀ ≤ 90 s |
| Calibration | Single-point air calibration |
| Compensation | Automatic temperature, atmospheric pressure, and salinity compensation |
| Operating Temperature | –5 to 50 °C |
| Max Pressure | 65 PSIG (4.5 bar) at 50 °C |
| Max Flow Rate | 10 ft/s |
| Housing Material | PEEK |
| Electrode System | Triple-electrode (Au cathode, Ag anode, Ag reference electrode) |
| Oxygen-permeable Membrane | PFA-coated Teflon |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial-Grade Water Quality Sensor Interface Platform |
| Model | AquaSensors DataStick |
| Communication Protocols | RS-232 (ASCII), Modbus RTU, Modbus RS-232, USB, DeviceNet, Ethernet, CANopen |
| Power Input | 10–36 V DC |
| Embedded Calibration Memory | Yes |
| Integrated Temperature Sensor | Yes |
| Compliance | CE, RoHS, IP68-rated housing (sensor head) |
| Software Compatibility | Thermo Fisher AquaLink Suite (v4.2+), third-party SCADA and PLC systems |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AquaSensors SST |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | BSB/BOD-OxiDirect |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–4000 mg/L |
| Detection Limit | 0.01 mg/L |
| Accuracy | ±0.5% of reading |
| Measurement Duration | Real-time, programmable incubation (1–28 days) |
| Repeatability | ±3% RSD |
| Sample Capacity | 6 independent channels |
| Display | Full-color LCD with real-time BOD trend graph and numeric mg/L readout |
| Data Storage | Internal memory with Bluetooth, USB 2.0, and SD card export |
| Environmental Compliance | Mercury-free operation, ISO 5815-1:2019 compliant methodology |
| Stirring System | Low-profile permanent-magnet stirrer with centering assurance |
| Accessories Included | Six 60-mL BOD amber glass bottles, six microprocessor-integrated pressure sensors, KOH absorbent pads, nitrification inhibitor (allylthiourea), 157 mL & 428 mL overflow calibration flasks, power supply, data cable, user manual, warranty card |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Reagent Shelf Life | 24 months (unopened) |
| Environmental Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Operating Temperature Range | Supports sample temperatures down to 4 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Chlorine XP |
| Instrument Type | Online Analyzer |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measured Parameters | Free Chlorine, Total Chlorine, Combined Chlorine |
| Range | 0.01–10 ppm |
| Accuracy | ±3% of reading |
| Repeatability | ±5% |
| Resolution | 0.01 ppm |
| Detection Limit | 0.01 ppm |
| Reagent Consumption | 0.03 mL per analysis |
| Calibration | Automatic blank calibration prior to each measurement |
| Light Source Management | Auto-adjusted LED intensity for extended lifetime |
| Cell Cleaning | Integrated automatic cuvette cleaning cycle |
| Enclosure Rating | IP65 (NEMA 4) |
| Communication Interface | RS-485 |
| Certifications | EPA Compliant, CSA Certified, ISO 9001 Certified |
| Reagent Shelf Life | 24 months (unopened), 60 days (in instrument) |
| Operating Temperature Range | Compatible with sample temperatures as low as 4°C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | C401 |
| Price | Upon Request |
| Chlorine Range | 0–1.99 ppm / 2.0–6.0 ppm |
| Chlorine Resolution | 0.01 ppm / 0.1 ppm |
| Chlorine Accuracy | ±0.02 ppm / ±0.2 ppm |
| pH Range | 5.9–8.2 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.1 |
| Cyanuric Acid Range | 5–90 ppm |
| Cyanuric Acid Resolution | 1 ppm |
| Cyanuric Acid Accuracy | ±4 ppm |
| Light Source | LED (525 nm) |
| Calibration | Single-point user-selectable per test |
| Operating Temperature | 0–50 °C |
| Power Supply | 4 × 1.5 V AAA batteries |
| Battery Life | >3000 measurements |
| IP Rating | IP67 |
| Dimensions (Instrument) | 15.5 × 6.8 × 4.6 cm |
| Weight (Instrument) | 200 g |
| Packaging Dimensions | 35.5 × 16.5 × 10.5 cm |
| Package Weight | 1170 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Ion 6+ |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 3-Star |
| Price | Upon Request |
| DO Range | 0.00–90.0 mg/L |
| DO Resolution | 0.1 / 0.01 mg/L |
| % Saturation Range | 0.0–600% |
| % Saturation Resolution | 1 / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| Calibration Methods | Air-saturated water, Water-saturated air, Winkler titration, Zero-point |
| Electrode Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Temp Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Input Interfaces | pH-BNC, temperature-miniDIN, stirrer-Phono-jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Logging | 1000 readings |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | Up to 10 user accounts |
| Power | 4×AA batteries |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | Benchtop—IP54 |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5-Star |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, US/NIST, DIN, or user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Units | M, mg/L, %, ppb, or unitless |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | down to 0.001 µS/cm (4-digit effective) |
| Conductivity Accuracy | ±0.5% ±1 digit or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | 2-electrode, 4-electrode, and planar conductivity cells |
| Conductivity Calibration | 1–5 points (manual) or 1–3 points (auto) |
| DO Range | 0.00–90.0 mg/L (0.0–600%) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration Methods | air-saturated water, water-saturated air, Winkler titration, zero-point |
| DO Sensor Type | polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temp Compensation | automatic or manual |
| Display | backlit LCD with icon-driven interface |
| Input Interfaces | pH–BNC, temperature–miniDIN, stirrer–phono jack (benchtop only) |
| Communication | bidirectional RS232, optional USB cable |
| Data Logging | 500 measurements |
| Calibration History | last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 user accounts |
| Power | 4×AA batteries (portable) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | benchtop–IP54 |
| Dimensions (benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Portable |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measurable Parameters | Free Chlorine, Total Chlorine, pH, Chlorine Dioxide, Cyanuric Acid |
| Free Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Total Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Chlorine Dioxide Range | 0–9 mg/L |
| pH Range | 5.9–8.2 |
| Cyanuric Acid Range | 5–90 mg/L |
| Sample Volume | 10 mL |
| Display | LCD |
| Power | 4×AAA batteries (≥3000 measurements, auto-off) |
| Ingress Protection | IP67 |
| Operating Environment | 0–50 °C, 0–90% RH (non-condensing at 30 °C) |
| Compliance | CE, TÜV, FCC Part 15 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Analyzer |
| Model | AQ3700 |
| Measurement Parameters | Total Phosphorus (TP), Total Nitrogen (TN), Chemical Oxygen Demand (COD) |
| Measurement Principle | Spectrophotometry |
| Measurement Range | 0.5–150 mg/L (TP/TN) |
| Accuracy | ≤ ±5% of reading |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Benchtop/Field Water Quality Analyzer |
| Model | AQ4000 |
| Wavelengths | 420 nm, 520 nm, 580 nm, 610 nm |
| Wavelength Accuracy | ±2 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Stray Light | <1.0% at 400 nm |
| Light Source | LED |
| Detector | Photodiode |
| Bandwidth | 10 ± 2 nm |
| Operating Temperature | 0.0–50.0 °C |
| Relative Humidity | ≤90% at 50.0 °C |
| Ingress Protection | IP67 |
| Power Supply | 4 × AA alkaline batteries (2500 h) or lithium batteries (10,000 h) |
| Data Storage | 100 test records |
| Interface | RS232 |
| Sample Cell Compatibility | 13 mm, 16 mm, 24 mm cuvettes |
| Auto-ID™ Support | 13 mm barcoded vials only |
| Preloaded Methods | 190 |
| User-Defined Methods | 10 |
| Display | LCD with unit support (g/L, mg/L, ppm, %T, Abs) |
| Auto-Zero & Blank Correction | Yes |
| Standby Mode | Yes |
| Firmware Update Capability | Yes |
| Memory Retention on Power Loss | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AQ4001 COD |
| Instrument Category | Portable |
| COD Range | 0–150 / 0–1500 / 0–15000 mg/L |
| Detection Limits | 1.5 / 15 / 150 mg/L |
| Detector | Photodiode |
| Wavelength Selection | 420, 520, 580, 610 nm (auto-selected) |
| Cuvette Sizes | 13 mm, 16 mm, 24 mm |
| Units | mg/L, ppm, Absorbance, % Transmittance |
| Ingress Protection | IP67 |
| Digestion Unit | AQUAfast COD165 |
| Power Supply | 100–220 V, 50–60 Hz |
| Heating Power | 400 W |
| Weight | 3.6 kg |
| Dimensions (L×W×H) | 155 × 95 × 275 mm |
| Temperature Control | PID microelectronic controller |
| Sensor | Pt100 Class A |
| Digestion Temperatures | 100, 120, 150, 160, 165 °C |
| Digestion Times | 30, 60, 120 min or continuous |
| Ramp Time | 10 min (20 → 165 °C) |
| Temp. Stability | ±0.5 °C |
| Temp. Accuracy | ±1 °C |
| Digestion Well Diameter | 16 mm |
| Number of Wells | 25 |
| Over-Temperature Protection | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AutoTration-500 |
| Price | Upon Request |
| Sample Capacity | 48 × 50 mL beakers or 28 × 150 mL beakers |
| Interface | RS232 |
| Operating Voltage | 90–240 V, 50/60 Hz |
| Positioning Accuracy | ±1.0 mm (all axes) |
| X-axis Travel / Accuracy | 510 mm / <0.1 mm |
| Y-axis Travel / Accuracy | 270 mm / <0.1 mm |
| Z-axis Travel / Accuracy / Zero Offset | 160 mm / <0.1 mm / 140 mm |
| Environmental Operating Range | 5–45 °C, 20–80 % RH |
| Certifications | CE |
| Power Consumption | 100 VA |
| Compatible Instruments | Thermo Fisher Orion Star Series Meters |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Dual Star |
| Pricing | Available Upon Request |
| Ammonia Electrode | 9512BNWP |
| Measurement Range | 0.01–17,000 ppm (as N) |
| Temperature Range | 0–50 °C |
| Electrode Slope | −54 to −60 mV/decade (at 25 ± 4 °C, ΔT < ±1 °C between solutions) |
| Repeatability | ±2% |
| Ion Concentration Resolution | 1–3 significant digits |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-02 |
| Electrode | 9502BNWP CO₂ Gas-Sensing Electrode |
| CO₂ Range | 4.4–440 ppm |
| pH Operating Range | 4.8–5.2 |
| Temperature Range | 0–50°C |
| Reproducibility | ±2% |
| Electrode Dimensions | 151 mm (L) × 17 mm (body Ø) × 22 mm (cap Ø) |
| Cable Length | 75 cm |
| Dual Channel Meter | pH/ISE Mode |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ISE Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| ORP Range | ±1999.9 mV |
| Temperature Range | −5 to 105°C |
| Temp Accuracy | ±0.1°C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Interface | Dual RS232 & optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-06 |
| Instrument Category | Sodium Ion Analyzer |
| Form Factor | Benchtop |
| Measurement Range | 0–19999 (in user-selectable units) |
| Detection Limit | 0.1 ppb (with 8411BNWP electrode and flow cell) |
| Response Time | < 30 s (t₉₀, typical) |
| Accuracy | ±0.1 mV (potential) or ±0.05% of reading (whichever is greater) |
| Temperature Range | −5 to 105 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | D10P-16 |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (Ag⁺) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±2% for Ag⁺, ±4% for S²⁻ |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Main Unit | Dual-channel pH/Ion Meter with GLP compliance, RS232 & USB connectivity, IP54 rating, 1000-data storage, 20 method memories |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-16N |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (S²⁻) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±4% for S²⁻, ±2% for Ag⁺ |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual Channel Capability | pH + ISE simultaneously |
| Ion Measurement Range | 0–19,999 units |
| Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temperature Accuracy | ±0.1°C (−5 to 99.9°C) |
| Display | Dual-channel LCD |
| Interfaces | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID) |
| Data Transfer | Bidirectional RS232 |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-17 |
| Instrument Category | Chloride Ion Analyzer |
| Electrode | 9617BNWP Chloride Composite Electrode |
| Measurement Range (Electrode) | 1.8–35,500 ppm Cl⁻ |
| pH Range | 2–12 |
| Temperature Range | 10–100 °C |
| Repeatability | ±2% |
| Minimum Sample Volume | 3 mL |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit | Dual Channel pH/ISE Meter |
| ISE Range | 0–19,999 (ppm, mg/L, M, %, or unitless) |
| ISE Resolution | 1–3 significant digits |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to +19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration Points | 1–6 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% |
| Temperature Range | −5 to +105 °C |
| Temp Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID support) |
| Data Interface | Bidirectional RS232, optional USB cable |
| Enclosure Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-19 |
| Instrument Category | Multi-Ion Analyzer |
| Electrode | 9719BNWP Potassium Composite Electrode |
| Measurement Range (K⁺) | 0.04–39,000 ppm |
| pH Compatibility | 2.5–11 |
| Temperature Range | 0–40 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit Ion Range | 0–19,999 (units: ppm, mg/L, M, %, or unitless) |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (instrument) | −5 to 105 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, dual reference electrode ports, dual MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Data Storage | 1,000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user passwords, method-level access control) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm H × 17.0 cm W × 22.4 cm D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-26 |
| Pricing | Available Upon Request |
| Electrode | 9606BNWP Cyanide Ion-Selective Electrode |
| Measuring Range (Cyanide) | 0.2–260 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | Length 110 mm, Body Diameter 13 mm, Cap Diameter 16 mm, Cable Length 1 m |
| Main Unit Ion Concentration Range | 0–19999, Resolution: 1–3 significant digits, Accuracy: ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999, Resolution: 0.1/0.01/0.001, Accuracy: ±0.001 pH |
| ORP Range | ±1999.9 mV, Resolution: 0.1 mV |
| Temperature Measurement | −5 to 105 °C, Accuracy: ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | Dual RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |