Empowering Scientific Discovery

Advanced Tech (Hong Kong) Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS/Stanford Research Systems
OriginUSA
ModelPG108
TypePortable Vacuum Measurement System
Operating TemperatureUp to 150 °C
SealingAll-metal construction with copper knife-edge gasket
Pressure Range1 × 10⁻⁸ Torr to 1000 Torr (dependent on ion gauge configuration)
Controller CompatibilityFully compatible with SRS IGC100 Intelligent Gauge Controller
Filament OptionsThO₂/Ir or tungsten, single- or dual-filament
Ion Gauge Types SupportedGlass-envelope, metal-envelope, and ultra-high-vacuum (UHV)-rated Bayard-Alpert gauges
ComplianceDesigned for integration into GLP/GMP-compliant vacuum systems requiring traceable, stable pressure monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS (Stanford Research Systems)
OriginUSA
ModelUGA Series
TypePortable Residual Gas Analyzer
Mass Range Options100 amu / 200 amu / 300 amu
ResolutionBetter than 0.5 amu (at 10% peak height)
Detection Limit<1 ppm
Operating Pressure Range1×10⁻⁶ Torr to 760 Torr (via configurable inlet)
Inlet ConfigurationsStainless-steel capillary (1–760 Torr), tubular channel (10⁻¹–10⁻⁴ Torr), 2.75" CF flange (<10⁻⁴ Torr)
Flow Rate1–10 sccm (at STP)
DetectorFaraday Cup & Electron Multiplier
Vacuum Pumping SystemIntegrated Turbo-Molecular Pump + Low-Pressure Diaphragm Pump
InterfaceGPIB, RS-232
SoftwareWindows-based RGA Control Suite with Real-Time Spectral Acquisition, Leak Detection Mode, Time-Pressure Plotting, and Multicomponent Quantitative Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS (Stanford Research Systems)
OriginUSA
ModelBGA244
PrincipleNon-dispersive Infrared (NDIR) Absorption
Form FactorPortable
Response Time<5 s
Repeatability±0.1% of full scale
Measurement Frequency4 Hz
Interface OptionsUSB, RS-232, RS-422
DisplayCapacitive Touchscreen
SoftwareBGAMon Data Acquisition & Control Suite
ComplianceCE, RoHS, NIST-traceable calibration support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
ModelGuardian Plus
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Measurable GasesCO₂ (0–3000 ppm to 0–100% vol), CH₄ (0–5% to 0–100% vol)
Output Options4–20 mA, RS-232/RS-485, Modbus RTU/TCP
Enclosure RatingIP65
Operating Temperature–10 °C to +50 °C
Power Supply24 VDC ±10%
ComplianceCE, UKCA, RoHS, EMC Directive 2014/30/EU
CalibrationFactory-calibrated with optional user-accessible zero/span adjustment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS/Stanford Research Systems
OriginUSA
ModelRGA
Mass Range100 amu / 200 amu / 300 amu
Resolution< 0.5 amu
Dynamic Range6 decades
Detection Limit5 × 10⁻¹⁴ Torr (with EM detector)
Sensitivity2 × 10⁴ A/Torr (FC), >200 A/Torr (EM)
Operating Pressure Range10⁻⁴ Torr to UHV (FC)
Max. Probe Temperature300 °C (without ECU)
Max. ECU Temperature70 °C
Detector OptionsFaraday Cup (standard), Electron Multiplier (optional)
InterfaceRS-232
SoftwareReal-time RGA Windows & LabVIEW drivers
Replaceable ComponentsFilament and electron multiplier in situ
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0