Empowering Scientific Discovery

Advanced Tech (Hong Kong) Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEO
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelTure8-based Integrated Glare Measurement System
PriceUSD 27,500 (approx. ¥200,000)
Imaging Luminance MeterTure8 (PR-930 equivalent)
SensorInstrument-grade monochrome CCD
Resolution3296 × 2472 (≥8.1 MP)
FOV (8 mm lens)150° × 120°
FOV (14 mm lens)60° × 50°
Luminance Range0.005–5×10⁶ cd/m² (with ND filters)
Luminance Accuracy±5% (8 mm lens, CIE 1931-weighted)
Calibration SuiteUniform-field, lens distortion, gradient, stray-light, illuminance, luminance/chrominance, and geometric scaling calibration
Compliant StandardsCIE 117:1995 (UGR), CIE 112:1994 (GR), CIE 140:2000 & CIE 150:2003 (TI), ISO/CIE joint guidance on glare assessment in lighting design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTEO
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelTEO
Price RangeUSD 70,000 – 112,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPHIR
OriginUSA
ModelHELIOS
Power Range200 W – 12 kW
Energy Range200 J – 5 kJ
Exposure Time0.3 s – 4 s
Wavelength Range750 nm – 1100 nm
Max Beam Diameter35 mm
Max Energy Density4 kJ/cm²
Accuracy±3%
Repeatability±1%
Response Time2.5 s
Measurement Interval12 s
Communication InterfacesPROFINET, RS232
Operating Temperature10–60 °C
Operating Humidity10–80% RH
Shutter ActivationAutomatic upon measurement initiation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabSphere
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTOCS-20
PricingAvailable Upon Request
Integration Options0.5 m, 1.0 m, 1.65 m, and 2.0 m integrating sphere configurations
Standards ComplianceIESNA LM-79-19, LM-80-15
Thermal ControlIntegrated TEC-based temperature stabilization with real-time junction/substrate temperature monitoring
Electrical MeasurementsCurrent (I), Voltage (V), Electrical Power (P)
Photometric MeasurementsLuminous Flux (lm), Luminous Efficacy (lm/W), Chromaticity Coordinates (CIE 1931 x,y
Thermal-Optical-Electrical CorrelationSimultaneous acquisition of L, V, I, and T under controlled thermal boundary conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginIsrael
ModelPD10-pJ-C
Detector TypeSilicon Photodiode
Minimum Measurable Pulse Energy10 pJ
Maximum Repetition Rate20 kHz
Spectral Range190–1800 nm
Output ConnectorSMA
Damage Threshold>100 MW/cm² (for 10 ns pulses at 1064 nm)
Active Area10 mm Ø
Rise Time<1 ns
InterfaceCompatible with Ophir StarLite, Juno, Vega, and Nova II meters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUPRtek
OriginTaiwan
ModelMD100N
Spectral Range380–780 nm
Spectral Resolution1 nm
FWHM~12 nm
Measurement AreaØ10 mm
Field of View±1°
Luminance Range0.001–5000 cd/m²
Luminance Accuracy±2% (100–5000 cd/m²), ±3% (0.2–100 cd/m²), ±4% (0.05–0.2 cd/m²)
Chromaticity Accuracy±0.002 CIE1931 x,y (100–5000 cd/m²), ±0.003 (0.2–100 cd/m²), ±0.005 (0.05–0.2 cd/m²)
Stray Light≤−25 dB
Polarization Error<2%
Integration Time100 µs–5000 ms
Digital Resolution16-bit
Flicker Sampling Rateup to 100 kS/s
Dimensions204 × 90 × 45 mm
Weight630 g ±10 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginIsrael
ModelPyrocam III / Pyrocam IV
Wavelength Range13–355 nm & 1.06–3000 µm
Detector TypeThermopile-based 2D array
InterfaceUSB 2.0 or GigE (model-dependent)
Active AreaUp to 12.5 × 12.5 mm²
Pixel Resolution128 × 128 (Pyrocam III), 320 × 320 (Pyrocam IV)
Damage Threshold≥500 MW/cm² (ns pulses), ≥10 kW/cm² (CW, with optional attenuators)
ComplianceCE, RoHS, ISO 17025 traceable calibration available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabsphere
OriginUSA
ModelRT/RTC
Coating OptionsSpectraflect® (300–2400 nm), Infragold® (0.7–20 µm)
ConfigurationRT (fixed 9°/h geometry), RTC (motorized or manual variable-angle sample stage)
Detector PortTop (RT), Bottom (RTC)
Standard ApertureFive 1-inch ports + 0.5-inch detector port
Mirror TrapIntegrated specular beam trap
Baffle DesignLow-profile, minimized obstruction for maximal wall visibility
Entrance GeometryKnife-edge apertures for wide-angle scatter collection
ComplianceASTM E1331, ISO 9050, ISO 13468, ISO 14782, CIE 110, USP <857>, FDA 21 CFR Part 11 (with optional software audit trail)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0