| Brand | StellarNet |
|---|---|
| Origin | USA |
| Model | Blue-Wave |
| Spectral Range | 280–900 nm |
| Detector Type | CCD |
| Optical Resolution | 0.75–6 nm (FWHM) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | 0.02% at 435 nm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-750 |
| Focal Length | 500 mm |
| F/# | F/9.7 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.02 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±10 pm |
| Stray Light Suppression | ≤2.6×10⁻⁵ |
| Grating Size | 68 mm × 68 mm |
| Dispersion | 2.6 nm/mm (at 300 nm, 2400 g/mm) |
| Slit Input Options | 1 or 2 |
| Detector Output Ports | 1 or 2 CCD ports + optional slit output |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Turret | 3-position, fully documented per unit |
| Brand | Andor |
|---|---|
| Origin | Israel |
| Model | SR193i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Range | 200–1100 nm |
| F/# | 3.6 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Focal Length | 193 mm |
| Imaging Optics | Aplanatic toroidal mirrors |
| Spectral Reproducibility | ±75 pm |
| Grating Turret | RFID-enabled, quick-release dual-grating turret |
| Detector Compatibility | Dual-output port for simultaneous CCD/EMCCD or sCMOS detector coupling |
| Slit Output Option | Configurable monochromator mode |
| Microscope Integration | C-mount and SM1-threaded interfaces compliant |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | MK350N Premium |
| Price Range | USD 2,800 – 7,000 |
| Brand | WITec |
|---|---|
| Origin | Germany |
| Model | Alpha 300S |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-163 |
| Optical Design | Czerny-Turner |
| Focal Length | 163 mm |
| F/# | f/3.6 |
| Wavelength Range | 300–500 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Wavelength Accuracy | ±0.25 nm |
| Wavelength Repeatability | ±0.05 nm |
| Stray Light | ≤0.3% T |
| Dispersion | 2.0 nm/mm (with specified grating) |
| Entrance Slit Options | Multiple fixed and adjustable slit widths |
| Grating Mount | Dual-grating turret (standard), up to 3 gratings optional |
| Detector Compatibility | Full integration with Andor CCD, ICCD, and EMCCD cameras |
| Imaging Plane Dimensions | 28 mm × 10 mm |
| Grating Size | 40 mm × 40 mm |
| Coupling Options | SMA fiber port, kinematic flange, motorized shutter, dynamic slit, silver-coated optics (SR-163-SIL variant) |
| Brand | Spectral Industries |
|---|---|
| Origin | Netherlands |
| Model | SPECTRAL LIBS |
| Type | Online, Integrated |
| Spectrometer | IRIS Echelle (UV/Deep-UV & NIR) |
| Laser | Actively Q-Switched Nanosecond Pulsed |
| Spectral Range | 180–800 nm & 880–1100 nm (N₂-purged option for DUV) |
| Resolution | 0.1–0.45 nm (@ 180–800 nm, 25 µm slit) |
| F/# | f/2 |
| Delay Jitter | <10 ns |
| Working Distance | 50–500 mm (customizable) |
| Spot Size | ≤100 µm |
| Detector | Deep-UV-enhanced CMOS, Integration Time: 28 µs – 30 s |
| Stage | Motorized 3-Axis Translation (50 × 50 mm travel) |
| Software | Full Hardware Control + MATLAB-Based Data Processing & Visualization |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-303i |
| Application Systems | Transmission & Reflectance Spectroscopy |
| Grating Turret | Triple-grating (motorized) |
| Spectral Resolution | 0.08 nm @ 2400 g/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Wavelength Range | 303–800 nm |
| F-number | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light Rejection | ≤0.3% T (typical), <2.2×10⁻⁵ (peak-to-valley) |
| Focal Length | 303 mm |
| Image Plane Dimensions | 28 mm × 14 mm |
| Slit Width Range | Motorized dynamic slit, up to 12 mm |
| Weight | 20 kg |
| Dimensions (L×W×H) | 394 × 238 × 208 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR303i |
| Spectral Range | 303–800 nm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Wavelength Repeatability | ±0.004 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Stray Light Suppression | ≤2.2×10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Input/Output Ports | Configurable (1 or 2 CCD outputs, motorized slit) |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Size | 68 mm × 68 mm |
| Slit Width | Dynamic, up to 12 mm |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR193i |
| Spectral Range | 200–1100 nm |
| F/# | 3.6 |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Grating Configuration | Dual-grating turret with RFID-enabled auto-identification |
| Optical Design | Imaging-corrected with toroidal mirrors |
| Detector Interfaces | Dual-output ports for simultaneous UV–NIR CCD/EMCCD/ICCD and InGaAs array or single-point detectors |
| Optional Coating | Silver-coated optics for enhanced NIR/SWIR throughput |
| Interface | USB 2.0, plug-and-play |
| Software Integration | Micro-Manager SDK-compatible spectral acquisition and analysis suite |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR-500i |
| Spectral Resolution | 0.05 nm |
| Wavelength Range | 180 nm – IR |
| Dispersion | 1.44 nm/mm |
| F/# | f/6.5 |
| Wavelength Accuracy | ±0.04 nm |
| Stray Light | 2.6 × 10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Focal Length | 500 mm |
| Entrance/Exit Ports | Up to 2 input and 2 output ports |
| Image Plane Dimensions | 28 mm × 14 mm |
| Physical Dimensions | 550 mm × 343 mm × 206.5 mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Omni-iSpecT Fiber-Coupled Raman Spectroscopy System |
| Laser Options | 532 nm (100 mW), 785 nm (350 mW) |
| Raman Shift Range | 200–4000 cm⁻¹ (532 nm) |
| Spectral Resolution | <10 cm⁻¹ (typical, @50 µm slit) |
| CCD Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm pixel size, -60 °C cooling, read noise <5 e⁻/pixel |
| Probe Working Distance | 3 mm / 7 mm (standard), customizable |
| Operating Temperature | 0–325 °C (customizable up to 400 °C) |
| Max Pressure Rating | 6000 psi |
| Probe Material | Hard-anodized aluminum + 316 stainless steel |
| Sealing | Perfluoroelastomer (FFKM) O-rings standard |
| Fiber Core | 100/100 µm (standard), SMA/MPO/10 mm cylindrical interface |
| Optical Throughput | F/1.8 (532 nm), F/2.3 (785 nm) |
| Grating | 1800 l/mm VPH (532 nm), 1200 l/mm VPH (785 nm) |
| Weight | 5.0 kg (spectrometer), 5.8 kg (full system) |
| Brand | ZOLIX |
|---|---|
| Model | Lifetime Aging Test System |
| Type | Integrated Automated OLED Degradation Monitoring Platform |
| Origin | Beijing, China |
| Power Supply | 5 kW / 380 V AC |
| Temperature Range Options | −40 °C to 150 °C, −20 °C to 150 °C, or 0 °C to 150 °C |
| Heating Rate | 2–4 °C/min (nonlinear, no-load) |
| Cooling Rate | 0.7–1.0 °C/min (nonlinear, no-load) |
| Temp. Resolution | ±0.01 °C |
| Humidity Range | 20–98% RH (within 25–85 °C) |
| Humidity Resolution | ±0.1% RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.0% RH |
| Humidity Deviation | ±3% RH (at >75% RH) |
| Channel Configurations | Up to 128 independent current/voltage monitoring channels |
| Control Interface | Touchscreen HMI with programmable temperature/humidity profiles |
| Compliance | Designed for GLP-aligned operational traceability and ASTM D7602-22 (Standard Practice for Accelerated Aging of Organic Light-Emitting Diode Devices) support |
| Brand | WITec |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alpha 300 Access |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 90–9000 cm⁻¹ |
| Spectral Resolution | ≤0.2 cm⁻¹ |
| Spatial Resolution | Lateral 350 nm, Axial 800 nm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤±0.02 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED/QLED Device Lifetime Testing System |
| Price Range | USD 14,000 – 28,000 |
| Channel Capacity | 32 / 64 / 128 (scalable to 512 channels) |
| Operating Modes | Constant Current, Constant Voltage, Constant Luminance (user-selectable) |
| Current Output Range | 0.03 µA – 100 mA (accuracy ±1% of reading) |
| Voltage Output Range | 1.0 – 20 V (accuracy <±1%) |
| Device Architecture Support | Bottom-emission, top-emission, inverted, and standard stack configurations (customizable per device architecture) |
| Substrate Compatibility | Standard 5 cm × 5 cm |
| Temperature Range | RT+10°C to 100°C (standard) |
| Environmental Options | Inert atmosphere testing (N₂/Ar), glovebox-integrated operation, UPS-backed power supply |
| Software Platform | LabVIEW-based control and data acquisition with real-time logging, timestamped event tracking, and export-ready CSV/Excel output |