Empowering Scientific Discovery

Advanced Tech (Hong Kong) Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
ModelT-10
ComplianceJIS C 1609-1:2006 Class AA (except f₂), DIN 5032-7 Class B
Measurement Range0.01–299,900 lx
Cosine Error (f₂)≤3%
Spectral Mismatch (f₁′)≤6%
OutputUSB + Analog (1 mV/digit, max 3 V)
Operating Temp−10–40°C
Battery Life≥72 h (alkaline)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
ModelMulti-Channel Calibration & Inspection System
OriginBeijing, China
TypeIntegrated Optical Calibration Platform
Core ComponentsIntegrating Sphere + Light-Tight Enclosure + Fiber-Optic Spectrometer + Precision Linear Motion Stage + Industrial Control Computer + Custom Calibration Software
Measurement ParametersLuminance (cd/m²), Chromaticity (CIE x,y / u'v'), Luminous Flux (lm), CCT (K), CRI (Ra), Dominant Wavelength (nm)
Positioning Accuracy±0.01 mm
Operation ModesIn-line and Off-line
ComplianceISO/CIE Standard Illumination Geometry (4π/2π), ASTM E308, CIE 15:2018, IEC 62471 (Photobiological Safety)
Data TraceabilityFull audit trail with timestamped measurement records, sample ID linkage, and user-access logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
ModelCL-200A
Illuminance Range0.1–99,990 lx
Luminance Range0.01–9,999 fcd
Chromaticity Accuracy (xy)±0.002 at 800 lx (Standard Illuminant A)
Repeatability (xy)±0.0005 (2σ)
Cosine Correction Error (f₂)<3%
f₁' Error vs. CIE Photopic Luminosity Function<6%
Response Time0.5 s (continuous measurement)
Operating Temp.−10–40°C, RH ≤85% (non-condensing)
Battery Life>72 h (alkaline, continuous use)
Dimensions69 × 174 × 35 mm
Weight215 g (without batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
ModelCL-500A
Spectral Range360–780 nm
Wavelength Interval1 nm
Spectral Bandwidth (FWHM)~10 nm
Wavelength Accuracy±0.3 nm (at 435.8, 546.1, 585.3 nm per JIS Z8724)
Illuminance Range0.1–100,000 lx
Illuminance Accuracy±2% ±1 digit (Std A source)
Chromaticity Accuracy (xy)±0.0015 (10–100,000 lx), ±0.002 (5–10 lx)
Repeatability (2σ, Std A)Ev: 0.5% + 1 digit
xy0.0005 (500–100,000 lx) to 0.004 (5–30 lx)
f₁′ (Relative Spectral Responsivity)≤1.5%
f₂ (Cosine Correction Error)≤3%
fₜ / fₕ (Temp./Humidity Drift)Ev: ±3%
xy±0.003
Measurement Time0.2 s (Ultra-fast, PC-connected), 0.5–27 s (Auto-exposure)
Dimensions70 × 165 × 83 mm
Weight350 g
Battery Life6 h (fully charged)
ComplianceJIS C 1609-1:2006 Class AA, DIN 5032-7 Class B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginJapan
ModelCS-200
Measurement PrincipleGrating-based spectral radiometry with linear photodiode array
Luminance Range0.01–20,000,000 cd/m² (angle-dependent)
Measurement Angles1°, 0.2°, 0.1°
Spectral MatchingCIE 1931 2° standard observer (V(λ), x(λ), y(λ), z(λ))
Accuracy (Lv, 1°)±2% ±1 digit
Chromaticity Accuracy (xy, 1°)±0.002–±0.007 (luminance-dependent)
Repeatability (Lv, 1°)±0.1% +1 digit to ±0.5% +1 digit
Minimum Measured Area0.1 mm (with close-up lens)
Minimum Working Distance296 mm
Measurement ModesLv xy, Lv u'v', Lv TΔuv, XYZ, Dominant Wavelength
SynchronizationVertical sync input (40.00–200.00 Hz)
InterfaceUSB 1.1
PowerAA alkaline batteries (≈3 h continuous operation)
Dimensions95 × 127 × 334 mm
Weight1.8 kg (body only)
Operating Environment0–40°C, ≤85% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhoto Research
OriginUSA
ModelPR1050
Dynamic Range500,000,000:1
Spectral Bandwidth2, 5, or 8 nm (auto-selectable)
DetectorBack-illuminated CCD, 512 pixels, thermoelectrically cooled
Color Accuracy (CIE 1931 x,y)±0.0015 at 5.14E−4 cd/m² (A-source, 2856 K, 2° FOV, 8 nm BW)
Color Repeatability±0.0005 at 1.19E−2 cd/m² (A-source, 2° FOV)
Luminance Sensitivity1.71E−5 cd/m² (10:1 SNR, 2° FOV, 8 nm BW)
Luminance Accuracy±2% (NIST-traceable A-source, 5.14E−4 cd/m²)
Luminance Repeatability≤1% (NIST-traceable A-source, 5.14E−4 cd/m²)
Exposure Time7 ms – 120 s
Polarization Error<0.2% (at 3.34 cd/m², 2° FOV)
Stray Light<0.06%
Wavelength Accuracy<0.4 nm
Spectral Resolution1 nm
Digital Resolution16-bit
InterfacesUSB, RS-232
Apertures2°, 1°, 0.5°, 0.25°, 0.2°, 0.125°, 0.1°, 0.1°×1° (vertical slit), 0.5°×1.5° (horizontal slit)
PowerRechargeable Li-ion battery or 90–240 VAC adapter
Battery LifeUp to 8 hours
Weight6.01 kg
Dimensions28.0 × 17.0 × 20.3 cm
Operating Temperature1–35 °C
Relative Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKonica Minolta
OriginJapan
ModelCL-70F
Illuminance Range (Continuous)1–200,000 lx
CCT Range1,563–100,000 K (xy display ≥5 lx)
Flash Mode20–20,500 lx·s
Spectral Range380–780 nm
Resolution1 nm
SensorCMOS linear image sensor
ComplianceJIS C1609-1:2006 Class AA, DIN 5032-7 Class C
Repeatability (2σ)EV ±1%+1 digit (30–200,000 lx), xy ±0.001 (500–200,000 lx)
InterfaceUSB 2.0 Mini-B
PowerUSB bus-powered
Operating Temp.−10 to +40 °C, RH ≤85% (non-condensing)
Dimensions73 × 183 × 27 mm (W×H×D, excluding protrusions)
Data Storage999 readings
SoftwareCL-SU1w (included)