Empowering Scientific Discovery

Advanced Tech (Hong Kong) Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCSTM-VCSEL-PW-060-LIVT
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRadiant Vision Systems
ModelTrueTest™
OriginUSA
TypeImaging Photometer-Based AOI System
ComplianceCIE 1931 Standard Observer, ISO 9241-307, ASTM E308, USP <1058> (for instrument qualification), FDA 21 CFR Part 11 (software audit trail enabled)
Detection CapabilitiesPixel defects, line defects, Mura (JND-mapped), luminance uniformity, chromaticity uniformity, contrast ratio, gamma, and spatial nonuniformity analysis
Software PlatformTrueTest™ Suite v6.0+ with JND-based defect quantification engine, GLP/GMP-compliant reporting, and automated pass/fail classification
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelZLPID-201
Price RangeUSD 700 – 1,400 (FOB)
Detection Range0–100,000 ppm (configurable spans)
Detection Limit1 ppb (typical, for isobutylene)
Response Time (T90)≤5 s
Operating Voltage3–5 V DC
Output Signal0.02–2.0 V (max 3.3 V)
Humidity Range0–99% RH (non-condensing)
Operating Temperature−40 to +60 °C
Storage Temperature0 to +25 °C
Pressure Range800–1200 mbar
Zero Voltage (U₀)>20 mV
Sensitivity≥40 mV/ppm (at low range, e.g., 0–100 ppm) down to ≥0.1 mV/ppm (at high range, e.g., 10,000–100,000 ppm)
Lifetime>24 months (typical continuous operation)
Calibration Gas RecommendationIsobutylene at ~50% of full scale
ComplianceRoHS-compliant construction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginIsrael
ModelL100(500)A-PF-120
Aperture Diameter120 mm
Spectral Range0.19–20 µm
Power Range20 W–120 kW
Position Accuracy±0.1 mm
Beam Size Accuracy±5%
CoolingActive Water Cooling
CalibrationMulti-wavelength NIST-traceable
Compatible MetersVega, Nova II, StarLite, Juno Interface
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeDistributor
Origin CategoryImported
ModelGonio-2Pi
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOPHIR
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFluxGage
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginIsrael
Model30(150)A-BB-18
CoolingConductive
Power Range30 mW–150 W (CW up to 50 W, Intermittent up to 150 W)
Wavelength Range0.15–20 µm
Absorber TypeBroadband BB Coating
OutputAnalog via BNC
Optional AccessoriesFiber Adapters, IPL-Specific Absorbers, Calibration Certificates (NIST-traceable)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCLAS-2D
PriceUSD 48,500 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRS (Stanford Research Systems)
OriginUSA
Model(s)SR280, SR250, SR255, SR240A, SR245, SR270, SR200, SR235
Key SpecificationsGate Width Range: 2 ns – 150 µs (SR250), down to 100 ps (SR255)
Sampling Averages1–10,000 cycles
RMS Jitter<2 ps (SR255)
Bandwidth350 MHz (SR240A)
Rise/Fall Time1.2 ns (SR240A)
InterfaceGPIB, RS-232, TTL I/O, 8-bit DIO, 8-channel analog I/O
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOphir
OriginIsrael
ModelPD10/30A-P-RP series
Sensor TypesPhotodiode & Pyroelectric Energy Sensors, RP (Real-time Pulse) Sensors
Wavelength Range0.15–20 µm (depending on model)
Energy Range10 pJ – 40 J
Avg. Power Range30 mW – 1500 W
Max. Repetition Rate25 kHz
Aperture SizesΦ10 mm to Φ96 mm
ComplianceISO 17025 traceable calibration, CE, RoHS
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0