- All
- Favorite
- Popular
- Most rated
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | JK-JG9000 |
| Price | USD 22,500 (FOB Beijing) |
| Dispersion Method | Wet Dispersion |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Measuring Range | 1–10,000 nm |
| Accuracy | <1% (D50, NIST-traceable standard reference material) |
| Repeatability | <1% (D50, same sample, 3 runs) |
| Laser Source | Fiber-coupled semiconductor laser, λ = 532 nm, lifetime >25,000 h |
| Detector | Hamamatsu high-sensitivity photomultiplier tube (PMT) |
| Scattering Angle | 90° |
| Sample Cell Volume | 4 mL |
| Temperature Control Range | 5–40 °C (±0.1 °C stability) |
| Test Duration | <5 min per run |
| Dimensions | 480 × 270 × 170 mm |
| Weight | 12 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-JG8000 |
| Price | USD 10,800 (FOB Beijing) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–2000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard) |
| Measurement Time | <2 min per run |
| Standard Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Detector Channels | 127 |
| Primary Laser | He–Ne, 632.8 nm, >3.0 mW |
| Auxiliary Laser | Semiconductor, 650 nm, >2.0 mW |
| Ultrasonic Dispersion | 40 kHz, 50 W |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 30 L/min |
| Sample Cell Volume | 1000 mL |
| Auto-Alignment System | Quadruple Hybrid Stepper Motor Drive, <1 µm positioning resolution |
| Dimensions | 1040 × 440 × 540 mm |
| Weight | 58 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-SZ2000 |
| Instrument Type | Scott Volumeter |
| Instrument Category | Benchtop Laboratory Densitometer |
| Sample Type | Free-Flowing Metallic Powders |
| Standard Compliance | GB/T 5060–1985 (equivalent to ISO 3923-2) |
| Measurement Principle | Gravimetric Volumetric Method with Controlled Flow Damping |
| Configuration | Integrated Funnel Assembly, Quadruple Baffle System, Cylindrical Receiving Cup (25.0 mL nominal volume), Stainless Steel Straightedge & Tapping Platform |
| Brand | Jingke Ruida (Kyocera-associated distribution channel) |
|---|---|
| Origin | Beijing, China |
| Model | JK-JG7000 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–780 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference materials) |
| Laser Source | He-Ne laser (632.8 nm, >2 mW) + auxiliary diode laser (650 nm, >2 mW) |
| Detector Channels | 77 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Auto-alignment | Four-phase hybrid stepper motor system |
| Analysis Modes | Free distribution, Rosin-Rammler, log-normal, and sieve-based grading |
| Output Formats | BMP, TXT, DOCX, XLSX |
| Software Interface | English & Chinese (localization-ready) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | JL-9100 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.001–3500 µm |
| Repeatability | >1% |
| Measurement Time | 10 seconds |
| Optical Principle | Laser Diffraction |
| Number of Size Channels | 32 |
| Sample Concentration Range | 0.002–0.2 vol% |
| Data Output | D10, D50, D90, Mode Diameter, Number/Volume/Weight-Average Diameters, Specific Surface Area, Histograms, Cumulative Curves, Fitting Accuracy |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JK-B4000 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Number of Analysis Stations | 1–6 |
| Specific Surface Area Range | 0.0001 m²/g (measured with Kr) to unlimited |
| Pore Size Range | 0.35 nm – 500 nm |
| Pressure Range | 0–133 kPa |
| Measurement Principle | Static Volumetric Method |
| Vacuum Base Pressure | ≤1×10⁻⁸ Torr |
| Relative Pressure Resolution (P/P₀) | down to 1×10⁻¹⁰ |
| Adsorption Gas Compatibility | N₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Minimum Detectable Pore Volume | 0.0001 cm³/g (N₂ at 77 K) |
| BET Repeatability | < ±1% |
| Analysis Time | ~25 min per BET surface area |
| Data Interface | USB or Ethernet (supports remote control & multi-instrument management) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤200 W |