Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7694
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Vial Heating Range15 °C above ambient to 220 °C (±1 °C accuracy)
Valve Heating Range15 °C above ambient to 220 °C (±1 °C accuracy)
Sample Loop Volumes0.5 mL, 1 mL, or 3 mL nickel tubing (user-selectable)
Vial Capacity44 positions
Vial Sizes10 mL and 20 mL standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelG1888
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity40 vials
Vial Size10 mL
Vial Heating Range35–210 °C (1 °C increments)
Valve & Transfer Line Temperature ControlAmbient to 210 °C
Loop Volume1 mL
ComplianceFDA 21 CFR Part 11, GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelTurboMatrix 40
Sample Capacity40 positions
Vial Size10 mL
Injection Valve Quantitative Loop Volume1 mL
Headspace Vial Heating Range35–210 °C (1 °C increments)
Injection Valve Temperature Control RangeAmbient to 210 °C
Sampling TechniquePressure-Balanced Static/Dynamic Headspace with Optional Trap Enrichment
Automation LevelFully Automated
CompatibilityUniversal GC interface (all major GC brands)
Regulatory Compliance Support21 CFR Part 11-ready software architecture (when paired with TurboMass or Chromera CDS)
Data Integrity FeaturesAudit trail, user access levels, electronic signatures (software-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (Kyocera)
OriginBeijing, China
ModelJK-O1
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity12 positions
Vial Sizes Supported10 mL and 20 mL
Valve Oven Temperature RangeAmbient to 180 °C (1 °C increments, ±0.3 °C stability)
Transfer Line Temperature RangeAmbient to 180 °C (1 °C increments, ±0.5 °C stability)
Sample Loop Volume1.0 mL (configurable)
Sample Loop MaterialStainless steel with 0.2 mm inner diameter tubing
ComplianceCompatible with global GC systems per ASTM D3699, USP <467>, ISO 11843-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelHS-40
Instrument TypeDynamic Headspace Sampler
Automation LevelFully Automatic
Vial Heating Range35–210 °C
Valve Temperature Control Range35–210 °C
Loop Volume1 mL
Sample Tray Capacity16 / 40 / 110 positions
Vial Sizes Supported10 mL and 20 mL
Sampling TechniquePressure-Balanced Headspace Injection
Compatible GC InterfacesUniversal (via standard GC inlet septumless or split/splitless ports)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyocera
OriginBeijing, China
ModelTP-6000
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Heating RangeAmbient to 450 °C
Valve & Transfer Line Temperature Control RangeAmbient to 210 °C (1 °C increment)
Quantitative Loop Volume1 mL
Vial Capacity9 positions
Vial Size10 mL
Temperature Stability< ±0.5 °C
RSD for Peak Area≤1.5% (under optimized conditions)
Equilibration/Injection/Clean Time Range0–60 min (user-programmable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7694E
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Vial Heating Range15 °C above ambient to 200 °C (±1 °C)
Valve Heating Range15 °C above ambient to 200 °C (±1 °C)
Sample Loop Volume1 mL
Vial Capacity44 positions
Compatible Vial Sizes10 mL and 20 mL
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0