| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7694 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | 15 °C above ambient to 220 °C (±1 °C accuracy) |
| Valve Heating Range | 15 °C above ambient to 220 °C (±1 °C accuracy) |
| Sample Loop Volumes | 0.5 mL, 1 mL, or 3 mL nickel tubing (user-selectable) |
| Vial Capacity | 44 positions |
| Vial Sizes | 10 mL and 20 mL standard |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | G1888 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 40 vials |
| Vial Size | 10 mL |
| Vial Heating Range | 35–210 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control | Ambient to 210 °C |
| Loop Volume | 1 mL |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 40 |
| Sample Capacity | 40 positions |
| Vial Size | 10 mL |
| Injection Valve Quantitative Loop Volume | 1 mL |
| Headspace Vial Heating Range | 35–210 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 210 °C |
| Sampling Technique | Pressure-Balanced Static/Dynamic Headspace with Optional Trap Enrichment |
| Automation Level | Fully Automated |
| Compatibility | Universal GC interface (all major GC brands) |
| Regulatory Compliance Support | 21 CFR Part 11-ready software architecture (when paired with TurboMass or Chromera CDS) |
| Data Integrity Features | Audit trail, user access levels, electronic signatures (software-dependent) |
| Brand | Jingke Ruida (Kyocera) |
|---|---|
| Origin | Beijing, China |
| Model | JK-O1 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Valve Oven Temperature Range | Ambient to 180 °C (1 °C increments, ±0.3 °C stability) |
| Transfer Line Temperature Range | Ambient to 180 °C (1 °C increments, ±0.5 °C stability) |
| Sample Loop Volume | 1.0 mL (configurable) |
| Sample Loop Material | Stainless steel with 0.2 mm inner diameter tubing |
| Compliance | Compatible with global GC systems per ASTM D3699, USP <467>, ISO 11843-2 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 35–210 °C |
| Valve Temperature Control Range | 35–210 °C |
| Loop Volume | 1 mL |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Sampling Technique | Pressure-Balanced Headspace Injection |
| Compatible GC Interfaces | Universal (via standard GC inlet septumless or split/splitless ports) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | TP-6000 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 450 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 210 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 9 positions |
| Vial Size | 10 mL |
| Temperature Stability | < ±0.5 °C |
| RSD for Peak Area | ≤1.5% (under optimized conditions) |
| Equilibration/Injection/Clean Time Range | 0–60 min (user-programmable) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7694E |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 15 °C above ambient to 200 °C (±1 °C) |
| Valve Heating Range | 15 °C above ambient to 200 °C (±1 °C) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 44 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |