Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRD
OriginUSA
ModelBGC-4500
Detection PrincipleGas Chromatography with Thermal Conductivity Detection (TCD)
Sample InterfaceDirect Pipeline Coupling
Analysis Cycle<10 min
Quantitative RepeatabilityRSD ≤ 1%
Temperature Control Accuracy±0.1°C
Operating Environment5–50°C, 10–85% RH
Power SupplyAC 220 V / DC 12 V / 24 V
Carrier GasHigh-Purity H₂ (≥99.995%), 0.3 MPa
Certified Standards ComplianceGB/T 13610–2020, GB/T 11062–2014, GB/T 12206–2006, ASTM D1945, ISO 6974–2, EN 16726
Data Output ProtocolModbus RTU
Software FeaturesReal-time Wobbe Index, Higher/Lower Heating Value (HHV/LHV), Density, Relative Density, Combustion Potential Calculation
Detector SensitivityTCD S ≥ 4500 mV·mL/mg (benzene), Noise ≤ 0.02 mV
Column3 mm ID Passivated Stainless Steel Capillary Column
Valve SystemImported VICI 10-Port Rotary Valve (≥5×10⁶ actuation cycles)
Sample RequirementsDust-free, Water-free, Oil-free Gas Stream
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (JKRD)
OriginUSA
ModelJK-8000
Detection PrincipleFlame Photometric Detection (FPD) with Dual FPD Configuration
Detection Wavelength394 nm
Minimum Detectable Sulfur Concentration≤0.02 ppm (v/v)
Sensitivity (as sulfur)≤8×10⁻¹² g/s
Baseline Noise≤0.5 mV/h
Oven Temperature RangeAmbient to 400 °C ±1 °C
Column Material CompatibilityPTFE-lined flow path
Sample TypesNatural gas, coal gas, coke oven gas, LPG, food-grade CO₂, flue gas, biogas
Regulatory ComplianceASTM D6667, ISO 8573-5, USP <621>, GLP/GMP-ready data handling
SoftwareIntegrated chromatography workstation with audit trail, peak integration, calibration curve generation, and report export (PDF/CSV)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJianghuan
OriginBeijing, China
ModelRPP-200A
Measurement PrincipleMicrocoulometric Titration (ASTM D3227, D5808, D7042
Analyte RangeS: 0.02–10,000 mg/L (up to wt%) / Cl: 0.1–10,000 mg/L (up to wt%)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Combustion TempAmbient to 1000 °C ±3 °C
RepeatabilityCV ≤ ±0.1 mg/L (X < 1.0 mg/L)
ComplianceASTM, ISO, IP, GB/T 11141, GB/T 17040, SH/T 0253, SH/T 0254
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (Kyocera)
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelJK-8000
PricingUpon Request
Detection PrincipleFlame Photometric Detection (FPD) with Dual FPD Configuration
Detection Wavelength394 nm (S-specific emission)
Minimum Detectable Sulfur≤0.02 ppm (v/v)
Sensitivity (S)1–8 × 10⁻¹² g/s
Baseline Noise≤0.5 mV/h
Oven Temperature RangeAmbient to 400 °C ±1 °C
Column CompatibilityReversible packed & wide-bore capillary columns
System MaterialsPTFE-lined flow path throughout
Regulatory ComplianceASTM D6667, ISO 8573-5, USP <232>/<233>, GLP-compliant data handling
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0