BrandBeifen Ruili
OriginBeijing, China
ModelWQF-510
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–400 cm⁻¹
Spectral Resolution0.85 cm⁻¹
Scan Velocity0.2–2.5 cm/s
Signal-to-Noise Ratio (S/N)15,000:1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGangdong
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFTIR-650
PricingAvailable Upon Request
Optical SystemMichelson Interferometer with KBr Beamsplitter
DetectorDTGS (Deuterated Triglycine Sulfate)
Spectral Range4000–400 cm⁻¹ (standard), extendable to 7800–375 cm⁻¹
Spectral Resolution0.5 cm⁻¹ (user-selectable down to 0.25 cm⁻¹)
Signal-to-Noise Ratio>15,000:1 (at 4 cm⁻¹, 1 min scan, peak height)
Scan Speed0.2–2.0 cm/s (interferometer mirror velocity)
ApertureAdjustable iris (2–10 mm)
Data FormatStandard JCAMP-DX v5.0 compliant
ComplianceCertified per JJG 812–2019 (China National Metrology Verification Regulation), Meets ISO/IEC 17025 requirements for spectral calibration traceability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Instrument TypeLaboratory FTIR Spectrometer
ModelTensor 27
Instrument CategoryFourier Transform Infrared Spectrometer
ConditionProfessionally Refurbished
ComplianceMeets ISO/IEC 17025 calibration traceability standards for used analytical instrumentation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelNicolet iS10
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–350 cm⁻¹
Spectral ResolutionBetter than 0.4 cm⁻¹
Scan Speed40 spectra/sec
Signal-to-Noise Ratio>50,000:1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelIRPrestige-21
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–400 cm⁻¹
Spectral Resolution0.85 cm⁻¹
Scan Velocity0.2–2.5 cm/s
Signal-to-Noise Ratio15,000:1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida
ModelWQF-520
TypeLaboratory FTIR Spectrometer
Spectral Range400–7800 cm⁻¹
Resolution<0.85 cm⁻¹
Wavenumber Accuracy±0.01 cm⁻¹
Scan Speed0.2–2.5 cm/s (motor-controlled, continuously adjustable)
SNR>15,000:1 (RMS, at 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition, DTGS detector)
BeamsplitterGe-coated KBr
DetectorStandard DTGS, optional MCT
SourceAir-cooled infrared source