| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WQF-510 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.85 cm⁻¹ |
| Scan Velocity | 0.2–2.5 cm/s |
| Signal-to-Noise Ratio (S/N) | 15,000:1 |
| Brand | Gangdong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTIR-650 |
| Pricing | Available Upon Request |
| Optical System | Michelson Interferometer with KBr Beamsplitter |
| Detector | DTGS (Deuterated Triglycine Sulfate) |
| Spectral Range | 4000–400 cm⁻¹ (standard), extendable to 7800–375 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ (user-selectable down to 0.25 cm⁻¹) |
| Signal-to-Noise Ratio | >15,000:1 (at 4 cm⁻¹, 1 min scan, peak height) |
| Scan Speed | 0.2–2.0 cm/s (interferometer mirror velocity) |
| Aperture | Adjustable iris (2–10 mm) |
| Data Format | Standard JCAMP-DX v5.0 compliant |
| Compliance | Certified per JJG 812–2019 (China National Metrology Verification Regulation), Meets ISO/IEC 17025 requirements for spectral calibration traceability |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR Spectrometer |
| Model | Tensor 27 |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Condition | Professionally Refurbished |
| Compliance | Meets ISO/IEC 17025 calibration traceability standards for used analytical instrumentation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Nicolet iS10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 0.4 cm⁻¹ |
| Scan Speed | 40 spectra/sec |
| Signal-to-Noise Ratio | >50,000:1 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | IRPrestige-21 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.85 cm⁻¹ |
| Scan Velocity | 0.2–2.5 cm/s |
| Signal-to-Noise Ratio | 15,000:1 |
| Brand | Jingke Ruida |
|---|---|
| Model | WQF-520 |
| Type | Laboratory FTIR Spectrometer |
| Spectral Range | 400–7800 cm⁻¹ |
| Resolution | <0.85 cm⁻¹ |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Scan Speed | 0.2–2.5 cm/s (motor-controlled, continuously adjustable) |
| SNR | >15,000:1 (RMS, at 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition, DTGS detector) |
| Beamsplitter | Ge-coated KBr |
| Detector | Standard DTGS, optional MCT |
| Source | Air-cooled infrared source |