Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginItaly
ModelHT200H Headspace Autosampler
Sample Capacity40 positions (for 10 mL or 20 mL headspace vials)
Sample Heating BlockSimultaneous heating of up to 6 vials
Heating Temperature Range40–150 °C
Heating Time Range0–23 h 59 min
Agitation Duration0–99 min
Agitation SpeedAdjustable
Syringe VolumeStandard 2.5 mL, optional 5 mL
Minimum Injection Volume0.01 mL
Injection Flow Rate0.1–100 mL/min
Equilibration Delay0–60 s
Needle Temperature Control40–150 °C
Carrier/Purge GasInert gas (N₂ or He)
Extraction ModeMultiple Headspace Extraction (MHE), up to 15 cycles
Software CompatibilityHT-Comsoft-H and Clarity Chromatography Data Systems
Position FlexibilityRemovable sample tray configurable for left- or right-side installation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelSIL-10AF
Instrument TypeGas Chromatography Autosampler
Sample Capacity100 × 1.5 mL vials (60 × 4 mL vials with cooling
Injection Volume Range1–50 µL (standard), up to 5000 µL (with optional loops)
Injection PrecisionRSD ≤ 0.5% at 10 µL (standard mode)
Needle WashProgrammable pre- and post-injection washing
Cooling Module CompatibilityOptional SIL-10C S/L cooler units
Temperature Control Range4–70 °C (cooler operation), Ambient Operating Range: 4–35 °C
pH Compatibility1–10
Dimensions (W×H×D)260 × 280 × 150 mm
Weight19 kg
Power SupplyAC 220 V, 59/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelSIL-10A
Instrument TypeGas Chromatography Autosampler
Sample CapacityUp to 192 positions (96-well microtiter plates × 2)
Standard Sample Volume Range1–50 µL
Optional Volume Rangeup to 5000 µL
Injection Accuracy≤0.5% RSD (10 µL, standard mode)
Sample Cooling Range4–70 °C
Operating Temperature4–35 °C
pH Compatibility1–10
Dimensions260 × 280 × 150 mm (W×H×D)
Weight19 kg
Power SupplyAC 220 V, 59/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyocera
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelAMTK Multifunctional HPLC Autosampler
PricingAvailable Upon Request
Sample Capacity120 × 2 mL vials (2 × 60-position racks)
Injection Volume Range0.1–1000 µL
PrecisionRSD < 0.5% (full-loop & partial-loop modes)
Carryover< 0.01%
LinearityR² > 0.999
Injection ModesFull-loop, Partial-loop, Needle-Over-Loop (NOL), and Zero-Dead-Volume (ZDV)
Quantitative Loop Options20, 50, 100 (standard), 200, 500 µL
Syringe Pump Options100, 250 (standard), 1000 µL
Valve Switching Time< 100 ms
Positioning Accuracy< 0.3 mm (XYZ 3-axis stepper motor control)
Wash ProtocolDual-wall (inner + outer needle) wash with unlimited cycles
Dimensions300 × 230 × 505 mm (L × H × W)
PowerAC 220 V, 50 Hz
CommunicationLAN & RS-232
SoftwareAMTK Chromatography Workstation
pH Compatibility1–14
System IntegrationFully compatible with Agilent, Waters, Shimadzu, Thermo Fisher, PerkinElmer, Elite, and other HPLC/UHPLC/IC platforms
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0