Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelAA-7000
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating (1800 lines/mm)
Optical SystemDouble-Beam
Detector TypeSolid-State Photodiode Array
Background CorrectionD₂ Lamp + Self-Reversal (Self-Absorption) Method
Wavelength Range190–900 nm
Spectral Bandwidth0.1 / 0.2 / 0.4 / 1.0 / 2.0 nm (motorized switching)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability≤±0.1 nm
Static Baseline Stability≤±0.002 A/30 min
Dynamic Baseline Stability≤±0.004 A/30 min
Resolution<0.3 nm
Cu Characteristic Concentration (Flame)≤0.02 µg/mL
Cu Detection Limit (Flame)≤0.005 µg/mL
RSD (Flame)≤1%
Atomizer Options50 mm & 100 mm Interchangeable Titanium Burner Heads
Graphite Furnace Power SupplyIntegrated (4 kW)
Dimensions (W×D×H)880 × 540 × 450 mm
Weight125 kg
Power Supply220 V, 50 Hz, Single Phase (Host: 200 W
GF Module4 kW)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionAutomatic D₂/Zeeman
Resolution0.3 nm
Sensitivity≥ 0.3 A for 5 ppm Cu solution
Repeatability (RSD)< 0.3%
Detection Limit (Cu)≤ 0.006 mg/L
ConditionFactory-Refurbished & Performance-Verified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelAAnalyst 600
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorConcave Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Self-Reversal
Resolution0.3 nm
SensitivityCu 5 ppm, Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection LimitCu ≤ 0.006 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelAA-7090
Price RangeUSD 4,200–7,000 (FOB)
Instrument TypeFlame and Graphite Furnace AAS (Parallel Configuration)
MonochromatorHolographic Grating
Optical SystemDual-Beam
DetectorSolid-State CCD Array
Background CorrectionAutomatic D₂ and Transverse AC Zeeman
Magnetic Field Strength0.6–1.1 T (0.1 T Adjustable Steps)
Lamp Turret8-Position Motorized
Lamp RecognitionEncoded Hollow Cathode Lamp Support
Graphite Furnace ImagingIntegrated Visual Monitoring System
Gas ControlDual-Path Programmable Gas Supply (Main + Auxiliary)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelAAnalyst 800
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionAutomatic Deuterium/Hollow Cathode Lamp (D₂/HCL)
Spectral Resolution0.3 nm
Sensitivity≥ 0.3 A for 5 ppm Cu solution
Precision (RSD)< 0.3%
Detection Limit (Cu)≤ 0.006 mg/L
ComplianceASTM E1921, ISO 7185, USP <731>, FDA 21 CFR Part 11–ready software environment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
Instrument TypeFlame/Graphite Furnace AAS
MonochromatorNot Specified (Grating-based)
Optical SystemDouble-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp
Resolution0.3 nm
Sensitivity5 µg/mL Cu
Repeatability (RSD)≤0.3%
Detection Limit (Cu)0.006 mg/L
ComplianceASTM D4294, ISO 11885, USP <231>, FDA Guidance for Elemental Impurities in Food
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelAA-7000
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorConcave Grating
Optical SystemDouble-Beam
DetectorSolid-State Detector
Background CorrectionDeuterium Lamp + Zeeman Effect
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
OriginBeijing, China
ModelAA990
Instrument TypeFlame and Graphite Furnace AAS
Optical SystemDual-Beam
ConditionProfessionally Refurbished & Fully Qualified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRD
ModelAA800
TypeFlame AAS
OriginBeijing, China
DetectorPhotomultiplier Tube (PMT)
Wavelength Range180–900 nm
Grating Density1800 lines/mm
MonochromatorCzerny-Turner
Spectral Bandwidths0.2 / 0.4 / 1.0 / 2.0 nm (auto-switching)
Wavelength Accuracy≤ ±0.1 nm
Wavelength Repeatability≤ ±0.025 nm
Baseline Drift≤ 0.003 ABS/30 min (static), ≤ 0.005 ABS/15 min (dynamic)
Resolution (Cu 324.7 nm, 0.2 nm BW)≤ 0.2 ± 0.01 nm
Characteristic Concentration (Cu)0.025 µg/mL / 1%
Detection Limit (Cu)0.006 µg/mL
Burner HeadTitanium, 0.5 mm × 100 mm
NebulizerHigh-efficiency glass-in-metal
Atomization ChamberCorrosion-resistant all-plastic
RSD (repeatability)≤ 0.5%
Safety FeaturesAuto-shutoff on acetylene leak detection, flame-out protection, gas flow monitoring
Power SupplyAC 220 V / 50 Hz, 150 W
Dimensions1000 × 400 × 470 mm (L×W×H)
Weight70 kg
SoftwareWindows XP/Vista/7 compatible, Chinese-language AAS control & quantitation suite with linear regression calibration, multi-point standard curve fitting, statistical reporting, and RS232/USB connectivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDongxifenxi
OriginBeijing, China
ModelAA-7000
Instrument TypeFlame and Graphite Furnace AAS
Optical SystemDual-beam
Monochromator TypeNot specified (standard grating-based)
DetectorSolid-state photodiode array
Background CorrectionAutomatic deuterium/hollow cathode lamp or Zeeman-based (configurable)
ConditionRefurbished & Factory-qualified used unit
ComplianceMeets GB/T 21187–2007 (Chinese national standard for AAS performance verification)
SoftwareDongxifenxi AAWin v3.x (GLP-compliant data handling, audit trail enabled)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0