Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelTOC-5000A
Instrument TypeLaboratory TOC Analyzer
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0–50,000 ppm C
Accuracy±4%
Detection Limit0.005 ppm C
Resolution0.001 ppb C
Repeatability≤3% RSD
Sample TypesLiquid (aqueous), Solid (soil, sludge, sediment, wipe samples), Suspended Solids-Rich Water
ComplianceDesigned for GLP/GMP environments with audit-ready operation
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelHach IL550
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleDirect Conductivity
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0–50,000 ppm TOC
Accuracy±3% of reading
Resolution0.001 ppb
Detection Limit0.05 ppm
Repeatability≤3% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOI Analytical
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDI1000
Power SupplyAC 220 V ± 10%, 50 Hz ± 1 Hz
Rated Power100 W (max), 40 W (standby)
Dimensions440 mm × 180 mm × 260 mm
Weight10 kg
Detection Limit0.001 mg/L
Quantification Range0.001–1.000 mg/L
Accuracy±5%
Repeatability≤3%
Zero Drift±5%
Span Drift±5%
Linearity±5%
Analysis Time4 min per sample
Response Time≤15 min
Sample Temperature Range1–95 °C
Internal Flow Rate0.5 mL/min
Relative Humidity≤85% RH
Display320 × 234 pixel full-color TFT LCD
Communication InterfacesRS-232, built-in thermal printer port
Data Storage12-month continuous logging with date/time stamping
ComplianceUSP <643>, Ph. Eur. 2.2.44, ChP TOC method
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelTOC-V
Instrument TypeLaboratory TOC Analyzer
Oxidation MethodHigh-Temperature Catalytic Combustion at 680 °C
Measurement Range0–50,000 ppm C
Accuracy±4%
Resolution0.001 ppb C
Detection Limit0.005 ppm C
Repeatability≤3% RSD
Detection PrincipleCatalytic Combustion Oxidation + NDIR Detection
Sample IntroductionProgrammable 8-Channel Syringe Pump
IC RemovalAutomated Acidification + Sparging (NPOC Mode)
Blank Water GenerationOnboard Deionized Water Purification System
ComplianceDesigned to support ASTM D7573, ISO 8245, USP <643>, and EPA Method 415.3 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyocera
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSP690
PriceUSD 2,100 (FOB Beijing)
Standard ComplianceJB/T 6244–1992, JJG 700–1990
Temperature Control ZonesColumn Oven, TCD Detector, FID Detector, Methanizer
Temperature Range7 °C above ambient to 399 °C
Temperature Stability±0.1 °C at 200 °C
Detection ModesTCD, FID (with optional methanizer)
Sample IntroductionSplit/splitless injector, compatible with headspace, purge-and-trap, vacuum degassing, and shaking degassing systems
Analytical CapabilitySimultaneous quantification of C₁–C₂ hydrocarbon gases (H₂, O₂, N₂, CH₄, CO, CO₂, C₂H₄, C₂H₆, C₂H₂) in transformer oil per IEC 60599 and ASTM D3612
Data AcquisitionDual-channel auto-switching, baseline correction, peak integration, retention time locking
Show next