| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | API 4000 Q-Trap |
| Instrument Type | Triple Quadrupole Linear Ion Trap Hybrid |
| Mass Range | 5–2000 m/z |
| Sensitivity | <10 fg on-column for SRM (e.g., reserpine) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (nominal mass instrument) |
| Ion Source Options | TurboIonSpray® and APCI® with plug-and-play interchangeability |
| Collision Cell | LINAC™ high-efficiency linear accelerator collision cell |
| Detection System | Pulse-counting electron multiplier |
| Dynamic Range | 1–4 × 10⁶ cps |
| Vacuum System | Dual-stage turbomolecular pumps with air-cooled design |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-free compressed air) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3000 |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | 10–3000 Da |
| Sensitivity | S/N ≥ 100:1 for 1 pg on-column reserpine (ESI+) |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Ion Sources | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle-filtered compressed air) |
| Vacuum System | Varian DS602 dual-stage rotary vane pump with oil mist filter |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | DRC-e |
| Mass Analyzer Type | Quadrupole |
| Resolution (FWHM at m/z 202) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity | Be ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹) |
| Vacuum System | Dual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Gas Options | H₂, He, CH₄, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Efficiency | > 10⁷-fold |
| Chemical Resolution | > 150,000 |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | < 0.08% RSD |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | Xevo TQ-S |
| Configuration | Refurbished System with Full Functional Validation |
| Ionization Compatibility | Electrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., APPI, ESCi) |
| Mass Analyzer Architecture | Three Sequential Quadrupole Stages (Q1 → Collision Cell → Q3) |
| Scan Modes | MRM, Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan, Selected Reaction Monitoring (SRM), RADAR™ Simultaneous Quantitation & Screening |
| Software Platform | MassLynx v4.2 or Later with TargetLynx XS, QuanLynx, and UNIFI Integration Capabilities |
| Regulatory Compliance Support | 21 CFR Part 11 Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (for reserpine, ESI+) |
| Resolution | Full Width at Half Maximum (FWHM) 0.5–0.7 m/z |
| Mass Accuracy | ±0.1 Da (internal calibration) |
| Configuration | Used / Refurbished System with HPLC Integration Capability |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B-5977B |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate or chlorobenzene (typical electron ionization, EI) |
| Scan Speed | 15,000 u/s |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC) |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Detection Limit (FID) | <5 pg C/s (propane) |
| Autosampler | Agilent 7683 with 100-position tray |
| Injection Volume | 0.1–100 µL |
| Total Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 7890A-5975C |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (at 10% valley, peak width at half height) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, using octafluoronaphthalene) |
| Scan Speed | 15,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8050 |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (unit mass) |
| Sensitivity | >300:1 (S/N, at 1 pg OFN, MRM mode) |
| Scan Speed | 15,000 u/s |
| Ion Source | High-brightness, low-contamination EI source |
| Detector | Ultra-high-gain electron multiplier with triple-noise-reduction architecture |
| Vacuum System | Dual-inlet, high-capacity turbomolecular pump (oil-free forepump, 3-year maintenance interval) |
| Software | LabSolutions Insight with Smart MRM and audit-trail-enabled precision management |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Quadrupole Mass Spectrometer (Single Quadrupole) |
| GC Compatibility | Agilent 6890 Series GC |
| Mass Range | Up to 1050 u |
| Ion Source | Inert, Temp-Controlled to 350 °C |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with AutoCI |
| Scan Speed | Up to 4.8 scans/sec (typical) |
| Resolution | Unit mass resolution (R = 1000, 10% valley) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI full-scan mode (S/N ≥ 20:1) |
| Data System | MSD ChemStation (G1701DA) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1.6–800 u (amu) |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (Full Scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| PCI Sensitivity | ≥75:1 S/N for 100 pg Benzophenone at m/z 183.1 |
| NCI Sensitivity | ≥500:1 S/N for 1 pg OFN at m/z 272 |
| Ion Source | Electron Ionization (EI), Chemical Ionization (CI), and Negative Chemical Ionization (NCI) capable |
| Ion Source Material | Molybdenum alloy, temperature-controlled |
| Quadrupole | Gold-coated quartz, hyperbolic rod set, heated and independently temperature-regulated |
| GC Oven Temperature Range | Ambient to 400 °C |
| Injector Types | Programmable Temperature Vaporizer (PTV) and Split/Splitless Capillary Injector |
| Mass Scan Modes | Full Scan, Selected Ion Monitoring (SIM), and Tuning |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2020 |
| Mass Range | 1–1000 u |
| Resolution | 1000–2000 (FWHM) |
| Sensitivity | >300:1 (S/N, full-scan, octafluoronaphthalene) |
| Scan Speed | 15,000 u/sec |
| Ion Source | Shielded high-efficiency electron ionization (EI) source with OD lens technology |
| Vacuum System | Dual 200 L/sec turbomolecular pumps (ion source + quadrupole) |
| Maximum Column Flow | 15 mL/min |
| Compliance | FDA 21 CFR Part 11, GLP/GMP audit trail capable via GCMS Insight software |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API4000 Q-Trap |
| Instrument Type | Hybrid Triple Quadrupole/Linear Ion Trap Mass Spectrometer |
| Mass Range | 5–2,000 m/z |
| Sensitivity | <10 fg on-column for reserpine (MRM, ESI+) |
| Resolution | Unit mass resolution in Q1 and Q3 |
| Mass Accuracy | ±0.2 Da (calibrated) |
| Scan Speed | Up to 6,000 Da/sec |
| Dynamic Range | 4 orders of magnitude (1–4 × 10⁶ cps) |
| Vacuum System | Dual-stage air-cooled turbomolecular pumps |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, 50/60 Hz |
| Required Gases | High-purity nitrogen (≥99.999%), zero-air (oil-free, particle- and hydrocarbon-free compressed air) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010SE |
| Instrument Type | Quadrupole GC-MS (not Orbitrap) |
| GC Type | Conventional Capillary GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (unit mass resolution at peak top) |
| Sensitivity | >300:1 (S/N, full-scan, 1 pg OFN) |
| Scan Speed | 15,000 u/s |
| Column Flow Capacity | Up to 4 mL/min He or N₂ |
| Ionization Mode | EI (electron ionization), optional CI |
| Detector | Electron multiplier |
| Data System | GCMSsolution v2.x or later |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | CP3800–2200 |
| Instrument Type | Ion Trap Mass Spectrometer |
| GC Configuration | Conventional Capillary GC |
| Mass Range | 1–1000 u |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | >300:1 (S/N, 1 pg octafluoronaphthalene, full scan, RMS) |
| Scan Speed | 15,000 u/s |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI), software-switchable without source exchange |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1100-1956 |
| Instrument Type | Single Quadrupole |
| Mass Range | 10–3000 amu |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da (typical, calibrated) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQD |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Mass Range | 10–3000 Da |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 Da (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-S |
| Instrument Type | Tandem Quadrupole Mass Spectrometer |
| Ionization Compatibility | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., ESCi, UniSpray) |
| Key Technology | StepWave™ Ion Optics, ScanWave™ Collision Cell, RADAR™ Acquisition Mode |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCMS-2010EV |
| Instrument Type | Single Quadrupole |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Scan Speed | Up to 6000 amu/sec |
| Ionization Modes | ESI±, APCI± (optional) |
| Polarity Switching | Simultaneous positive/negative ion acquisition |
| Acquisition Modes | Full Scan, SIM, CID, Multi-Sequential Analysis (up to 64 methods per run) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 Plus |
| GC Platform | GC-2010 Plus AF |
| Mass Analyzer Type | Quadrupole (not Orbitrap) |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (unit mass resolution at peak top) |
| Sensitivity | >300:1 (S/N, octafluoronaphthalene, full scan, 1 pg injected) |
| Scan Speed | 15,000 u/s |
| Detector | Electron Multiplier |
| Ion Source | EI/CI (dual-mode, standard) |
| Column Oven Cooling Rate | ≤3.5 min (from 300 °C to 50 °C) |
| Advanced Flow Technology (AFT) | Yes |
| Compliance | ASTM D5845, ISO 17025, USP <621>, FDA 21 CFR Part 11 (software-enabled) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | TSQ Quantum Ultra |
| Configuration | Refurbished & Fully Qualified System |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Software Platform | Xcalibur 2.0.x or later with Tune 2.0.x |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LCMS-8045 |
| Instrument Type | Triple Quadrupole (TQ) |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Polarity Switching Time | 5 ms |
| Scan Speed | 30,000 u/sec |
| Step Size | 0.1 u |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1.2–1050 amu (0.1 amu increment) |
| Resolution | Unit Mass Resolution |
| Sensitivity | Auto-tune Mode |
| Scan Speed | 150,000 u/s |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | TQD |
| Configuration | Integrated UPLC/MS/MS System |
| Ionization Options | Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Range | 50–1200 m/z |
| Typical MRM Sensitivity | <10 fg on-column for reserpine (S/N ≥ 20:1) |
| Scan Speed | Up to 8,000 Da/sec in MRM mode |
| Collision Cell | T-Wave™ RF-only quadrupole collision cell |
| Data Acquisition Rate | ≥20 MRM transitions/sec |
| Software Platform | MassLynx v4.1 with TargetLynx, QuanLynx, QCMonitor, RADAR, TrendPlot, InliStart, and Quanpedia modules |
| Compliance | Fully compatible with 21 CFR Part 11 audit trail requirements and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TSQ Quantum Access MAX |
| Instrument Type | Triple Quadrupole (TQ) |
| Mass Range | 10–3000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine, ESI+) |
| Resolution | 0.5–0.7 m/z (FWHM) |
| Mass Accuracy | ≤ 0.1 Da (external calibration) |