BrandSCIEX
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPI 4000 Q-Trap
Instrument TypeTriple Quadrupole Linear Ion Trap Hybrid
Mass Range5–2000 m/z
Sensitivity<10 fg on-column for SRM (e.g., reserpine)
ResolutionUnit mass resolution (0.7 Da full width at half maximum)
Accurate Mass CapabilityNot applicable (nominal mass instrument)
Ion Source OptionsTurboIonSpray® and APCI® with plug-and-play interchangeability
Collision CellLINAC™ high-efficiency linear accelerator collision cell
Detection SystemPulse-counting electron multiplier
Dynamic Range1–4 × 10⁶ cps
Vacuum SystemDual-stage turbomolecular pumps with air-cooled design
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle-free compressed air)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI 3000
Instrument TypeTriple Quadrupole LC-MS/MS
Mass Range10–3000 Da
SensitivityS/N ≥ 100:1 for 1 pg on-column reserpine (ESI+)
Resolution0.5–0.7 Da (FWHM)
Mass Accuracy±0.1 Da
Ion SourcesElectrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle-filtered compressed air)
Vacuum SystemVarian DS602 dual-stage rotary vane pump with oil mist filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelDRC-e
Mass Analyzer TypeQuadrupole
Resolution (FWHM at m/z 202)≤ 0.8 amu
Detection Limitsub-ppq ng·L⁻¹
SensitivityBe ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹)
Vacuum SystemDual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min)
Linear Dynamic Range9 orders of magnitude
DRC Gas OptionsH₂, He, CH₄, NH₃, O₂, N₂O, CO₂
Interference Reduction Efficiency> 10⁷-fold
Chemical Resolution> 150,000
Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag)< 0.08% RSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelXevo TQ-S
ConfigurationRefurbished System with Full Functional Validation
Ionization CompatibilityElectrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., APPI, ESCi)
Mass Analyzer ArchitectureThree Sequential Quadrupole Stages (Q1 → Collision Cell → Q3)
Scan ModesMRM, Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan, Selected Reaction Monitoring (SRM), RADAR™ Simultaneous Quantitation & Screening
Software PlatformMassLynx v4.2 or Later with TargetLynx XS, QuanLynx, and UNIFI Integration Capabilities
Regulatory Compliance Support21 CFR Part 11 Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (for reserpine, ESI+)
ResolutionFull Width at Half Maximum (FWHM) 0.5–0.7 m/z
Mass Accuracy±0.1 Da (internal calibration)
ConfigurationUsed / Refurbished System with HPLC Integration Capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Model7890B-5977B
Instrument TypeIon Trap Mass Spectrometer
Chromatography TypeConventional Gas Chromatography-Mass Spectrometry
Mass Range1–1000 m/z
Resolution1000–2000 (full width at half maximum, FWHM)
Sensitivity>300:1 signal-to-noise ratio (S/N) for methyl stearate or chlorobenzene (typical electron ionization, EI)
Scan Speed15,000 u/s
Inlet Pressure Range0–100 psi (optional 0–150 psi)
Carrier Gas Flow ControlElectronic Pressure Control (EPC)
Oven Temperature Range4 °C above ambient to 450 °C
Detection Limit (FID)<5 pg C/s (propane)
AutosamplerAgilent 7683 with 100-position tray
Injection Volume0.1–100 µL
Total Flow Range0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
Model7890A-5975C
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ConfigurationConventional GC-MS
Mass Rangem/z 1–1000
Resolution1000–2000 (at 10% valley, peak width at half height)
Sensitivity>300:1 (Signal-to-Noise Ratio, SIM mode, using octafluoronaphthalene)
Scan Speed15,000 u/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-TQ8050
Mass Range1–1000 m/z
Resolution1000–2000 (unit mass)
Sensitivity>300:1 (S/N, at 1 pg OFN, MRM mode)
Scan Speed15,000 u/s
Ion SourceHigh-brightness, low-contamination EI source
DetectorUltra-high-gain electron multiplier with triple-noise-reduction architecture
Vacuum SystemDual-inlet, high-capacity turbomolecular pump (oil-free forepump, 3-year maintenance interval)
SoftwareLabSolutions Insight with Smart MRM and audit-trail-enabled precision management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Instrument TypeQuadrupole Mass Spectrometer (Single Quadrupole)
GC CompatibilityAgilent 6890 Series GC
Mass RangeUp to 1050 u
Ion SourceInert, Temp-Controlled to 350 °C
Ionization ModesElectron Ionization (EI) and Chemical Ionization (CI) with AutoCI
Scan SpeedUp to 4.8 scans/sec (typical)
ResolutionUnit mass resolution (R = 1000, 10% valley)
Sensitivity<10 fg OFN (octafluoronaphthalene) in EI full-scan mode (S/N ≥ 20:1)
Data SystemMSD ChemStation (G1701DA)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ConfigurationConventional Capillary GC-MS
Mass Range1.6–800 u (amu)
Mass Accuracy±0.1 u
EI Sensitivity≥20:1 S/N for 1 pg OFN at m/z 272 (Full Scan)
SIM Sensitivity≥10:1 S/N for 20 fg OFN at m/z 272
PCI Sensitivity≥75:1 S/N for 100 pg Benzophenone at m/z 183.1
NCI Sensitivity≥500:1 S/N for 1 pg OFN at m/z 272
Ion SourceElectron Ionization (EI), Chemical Ionization (CI), and Negative Chemical Ionization (NCI) capable
Ion Source MaterialMolybdenum alloy, temperature-controlled
QuadrupoleGold-coated quartz, hyperbolic rod set, heated and independently temperature-regulated
GC Oven Temperature RangeAmbient to 400 °C
Injector TypesProgrammable Temperature Vaporizer (PTV) and Split/Splitless Capillary Injector
Mass Scan ModesFull Scan, Selected Ion Monitoring (SIM), and Tuning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelGCMS-QP2020
Mass Range1–1000 u
Resolution1000–2000 (FWHM)
Sensitivity>300:1 (S/N, full-scan, octafluoronaphthalene)
Scan Speed15,000 u/sec
Ion SourceShielded high-efficiency electron ionization (EI) source with OD lens technology
Vacuum SystemDual 200 L/sec turbomolecular pumps (ion source + quadrupole)
Maximum Column Flow15 mL/min
ComplianceFDA 21 CFR Part 11, GLP/GMP audit trail capable via GCMS Insight software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI4000 Q-Trap
Instrument TypeHybrid Triple Quadrupole/Linear Ion Trap Mass Spectrometer
Mass Range5–2,000 m/z
Sensitivity<10 fg on-column for reserpine (MRM, ESI+)
ResolutionUnit mass resolution in Q1 and Q3
Mass Accuracy±0.2 Da (calibrated)
Scan SpeedUp to 6,000 Da/sec
Dynamic Range4 orders of magnitude (1–4 × 10⁶ cps)
Vacuum SystemDual-stage air-cooled turbomolecular pumps
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle- and hydrocarbon-free compressed air)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelQP2010SE
Instrument TypeQuadrupole GC-MS (not Orbitrap)
GC TypeConventional Capillary GC-MS
Mass Rangem/z 1–1000
Resolution1000–2000 (unit mass resolution at peak top)
Sensitivity>300:1 (S/N, full-scan, 1 pg OFN)
Scan Speed15,000 u/s
Column Flow CapacityUp to 4 mL/min He or N₂
Ionization ModeEI (electron ionization), optional CI
DetectorElectron multiplier
Data SystemGCMSsolution v2.x or later
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVarian
OriginUSA
ModelCP3800–2200
Instrument TypeIon Trap Mass Spectrometer
GC ConfigurationConventional Capillary GC
Mass Range1–1000 u
Resolution1000–2000 (FWHM at m/z 502)
Sensitivity>300:1 (S/N, 1 pg octafluoronaphthalene, full scan, RMS)
Scan Speed15,000 u/s
Ionization ModesElectron Ionization (EI) and Chemical Ionization (CI), software-switchable without source exchange
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model1100-1956
Instrument TypeSingle Quadrupole
Mass Range10–3000 amu
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da (typical, calibrated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelXevo TQD
Instrument TypeTandem Quadrupole (QqQ)
Mass Range10–3000 Da
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 Da (FWHM)
Mass Accuracy±0.1 Da
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelXevo TQ-S
Instrument TypeTandem Quadrupole Mass Spectrometer
Ionization CompatibilityElectrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., ESCi, UniSpray)
Key TechnologyStepWave™ Ion Optics, ScanWave™ Collision Cell, RADAR™ Acquisition Mode
Regulatory AlignmentDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLCMS-2010EV
Instrument TypeSingle Quadrupole
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
Scan SpeedUp to 6000 amu/sec
Ionization ModesESI±, APCI± (optional)
Polarity SwitchingSimultaneous positive/negative ion acquisition
Acquisition ModesFull Scan, SIM, CID, Multi-Sequential Analysis (up to 64 methods per run)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelQP2010 Plus
GC PlatformGC-2010 Plus AF
Mass Analyzer TypeQuadrupole (not Orbitrap)
Mass Rangem/z 1–1000
Resolution1000–2000 (unit mass resolution at peak top)
Sensitivity>300:1 (S/N, octafluoronaphthalene, full scan, 1 pg injected)
Scan Speed15,000 u/s
DetectorElectron Multiplier
Ion SourceEI/CI (dual-mode, standard)
Column Oven Cooling Rate≤3.5 min (from 300 °C to 50 °C)
Advanced Flow Technology (AFT)Yes
ComplianceASTM D5845, ISO 17025, USP <621>, FDA 21 CFR Part 11 (software-enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeAuthorized Distributor
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTSQ Quantum Ultra
ConfigurationRefurbished & Fully Qualified System
Regulatory ComplianceDesigned for GLP/GMP environments
Software PlatformXcalibur 2.0.x or later with Tune 2.0.x
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLCMS-8045
Instrument TypeTriple Quadrupole (TQ)
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
Polarity Switching Time5 ms
Scan Speed30,000 u/sec
Step Size0.1 u
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model7890A-7000B
Instrument TypeTriple Quadrupole Mass Spectrometer
Chromatography TypeConventional GC-MS
Mass Range1.2–1050 amu (0.1 amu increment)
ResolutionUnit Mass Resolution
SensitivityAuto-tune Mode
Scan Speed150,000 u/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTQD
ConfigurationIntegrated UPLC/MS/MS System
Ionization OptionsElectrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
Mass Range50–1200 m/z
Typical MRM Sensitivity<10 fg on-column for reserpine (S/N ≥ 20:1)
Scan SpeedUp to 8,000 Da/sec in MRM mode
Collision CellT-Wave™ RF-only quadrupole collision cell
Data Acquisition Rate≥20 MRM transitions/sec
Software PlatformMassLynx v4.1 with TargetLynx, QuanLynx, QCMonitor, RADAR, TrendPlot, InliStart, and Quanpedia modules
ComplianceFully compatible with 21 CFR Part 11 audit trail requirements and GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelTSQ Quantum Access MAX
Instrument TypeTriple Quadrupole (TQ)
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy≤ 0.1 Da (external calibration)