Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPI 4000 Q-Trap
Instrument TypeTriple Quadrupole Linear Ion Trap Hybrid
Mass Range5–2000 m/z
Sensitivity<10 fg on-column for SRM (e.g., reserpine)
ResolutionUnit mass resolution (0.7 Da full width at half maximum)
Accurate Mass CapabilityNot applicable (nominal mass instrument)
Ion Source OptionsTurboIonSpray® and APCI® with plug-and-play interchangeability
Collision CellLINAC™ high-efficiency linear accelerator collision cell
Detection SystemPulse-counting electron multiplier
Dynamic Range1–4 × 10⁶ cps
Vacuum SystemDual-stage turbomolecular pumps with air-cooled design
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle-free compressed air)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI 3000
Instrument TypeTriple Quadrupole LC-MS/MS
Mass Range10–3000 Da
SensitivityS/N ≥ 100:1 for 1 pg on-column reserpine (ESI+)
Resolution0.5–0.7 Da (FWHM)
Mass Accuracy±0.1 Da
Ion SourcesElectrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle-filtered compressed air)
Vacuum SystemVarian DS602 dual-stage rotary vane pump with oil mist filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelXevo TQ-S
ConfigurationRefurbished System with Full Functional Validation
Ionization CompatibilityElectrospray (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., APPI, ESCi)
Mass Analyzer ArchitectureThree Sequential Quadrupole Stages (Q1 → Collision Cell → Q3)
Scan ModesMRM, Full Scan, Product Ion Scan, Precursor Ion Scan, Neutral Loss Scan, Selected Reaction Monitoring (SRM), RADAR™ Simultaneous Quantitation & Screening
Software PlatformMassLynx v4.2 or Later with TargetLynx XS, QuanLynx, and UNIFI Integration Capabilities
Regulatory Compliance Support21 CFR Part 11 Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (for reserpine, ESI+)
ResolutionFull Width at Half Maximum (FWHM) 0.5–0.7 m/z
Mass Accuracy±0.1 Da (internal calibration)
ConfigurationUsed / Refurbished System with HPLC Integration Capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI4000 Q-Trap
Instrument TypeHybrid Triple Quadrupole/Linear Ion Trap Mass Spectrometer
Mass Range5–2,000 m/z
Sensitivity<10 fg on-column for reserpine (MRM, ESI+)
ResolutionUnit mass resolution in Q1 and Q3
Mass Accuracy±0.2 Da (calibrated)
Scan SpeedUp to 6,000 Da/sec
Dynamic Range4 orders of magnitude (1–4 × 10⁶ cps)
Vacuum SystemDual-stage air-cooled turbomolecular pumps
Operating Temperature15–30 °C
Power Supply208–240 V AC, 50/60 Hz
Required GasesHigh-purity nitrogen (≥99.999%), zero-air (oil-free, particle- and hydrocarbon-free compressed air)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model1100-1956
Instrument TypeSingle Quadrupole
Mass Range10–3000 amu
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da (typical, calibrated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelXevo TQD
Instrument TypeTandem Quadrupole (QqQ)
Mass Range10–3000 Da
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 Da (FWHM)
Mass Accuracy±0.1 Da
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelXevo TQ-S
Instrument TypeTandem Quadrupole Mass Spectrometer
Ionization CompatibilityElectrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), and Optional Sources (e.g., ESCi, UniSpray)
Key TechnologyStepWave™ Ion Optics, ScanWave™ Collision Cell, RADAR™ Acquisition Mode
Regulatory AlignmentDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLCMS-2010EV
Instrument TypeSingle Quadrupole
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
Scan SpeedUp to 6000 amu/sec
Ionization ModesESI±, APCI± (optional)
Polarity SwitchingSimultaneous positive/negative ion acquisition
Acquisition ModesFull Scan, SIM, CID, Multi-Sequential Analysis (up to 64 methods per run)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeAuthorized Distributor
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTSQ Quantum Ultra
ConfigurationRefurbished & Fully Qualified System
Regulatory ComplianceDesigned for GLP/GMP environments
Software PlatformXcalibur 2.0.x or later with Tune 2.0.x
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLCMS-8045
Instrument TypeTriple Quadrupole (TQ)
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
Polarity Switching Time5 ms
Scan Speed30,000 u/sec
Step Size0.1 u
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTQD
ConfigurationIntegrated UPLC/MS/MS System
Ionization OptionsElectrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
Mass Range50–1200 m/z
Typical MRM Sensitivity<10 fg on-column for reserpine (S/N ≥ 20:1)
Scan SpeedUp to 8,000 Da/sec in MRM mode
Collision CellT-Wave™ RF-only quadrupole collision cell
Data Acquisition Rate≥20 MRM transitions/sec
Software PlatformMassLynx v4.1 with TargetLynx, QuanLynx, QCMonitor, RADAR, TrendPlot, InliStart, and Quanpedia modules
ComplianceFully compatible with 21 CFR Part 11 audit trail requirements and GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelTSQ Quantum Access MAX
Instrument TypeTriple Quadrupole (TQ)
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy≤ 0.1 Da (external calibration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelSCIEX 5500
Instrument TypeTriple Quadrupole Mass Spectrometer
ConfigurationLiquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Mass Rangem/z 5–2000 (typical for QqQ operation)
Polarity Switching Speed≤ 50 ms
MRM Dwell Timedown to 1 ms
Ion Source OptionsTurbo V™, DuoSpray™, PhotoSpray™
Ion GuideQJet™ 2 Collision Cell
Software PlatformAnalyst® 1.7.1 or later
Regulatory ComplianceDesigned for 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, user access control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI 4000
Instrument TypeTandem Quadrupole (QqQ)
Ionization ModesElectrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI)
Software PlatformAnalyst® 1.6.3 or later
Regulatory ComplianceDesigned for GLP/GMP environments
Mass Rangem/z 5–3,000 (typical operational range)
SensitivitySub-femtogram on-column detection for selected pharmaceutical compounds (e.g., ≤5 fg on-column for midazolam in MRM mode)
ResolutionUnit mass resolution (0.7 Da full width at half maximum, FWHM)
Mass Accuracy±0.2 Da (calibrated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Instrument TypeTriple Quadrupole (QQQ)
ModelLC-MS 1200-6410
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
Flow Rate Compatibility0.1–2.5 mL/min
Ion SourceJet Stream Electrospray Ionization (ESI)
Optional Ion SourcesAPCI, APPI
SoftwareMassHunter Workstation (Enhanced QQQ Edition)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeTandem Quadrupole (QqQ) LC-MS/MS
ModelXevo TQD
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
ConfigurationIncludes UPLC Binary Solvent Manager, Sample Manager, Sample Organizer, CH-A Column Heater, E2M28 Vacuum Pump, SB-C18 Column (50 mm × 2.1 mm, 1.8 µm), MassLynx Software Suite (InliStart, Quanpedia, QCMonitor, TargetLynx, TrendPlot), and RADAR™ Acquisition Mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelTriple Quad 5500
Instrument TypeTandem Quadrupole (QqQ) LC-MS/MS
Ionization SourcesTurbo V, DuoSpray, PhotoSpray
Key TechnologyeQ Electronics (50 ms polarity switching)
SoftwareAnalyst® 1.7 or later
ComplianceDesigned for GLP/GMP environments
Dimensions114 cm × 81 cm × 76 cm (W × D × H)
Weight~350 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLCMS-8080
Instrument TypeTriple Quadrupole (TQ)
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, ESI+)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da
ConfigurationLC-MS/MS system with heated electrospray ionization (HESI) source
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAB-4000
Instrument TypeTriple Quadrupole (QqQ)
Mass Range5–2,000 m/z
Sensitivity<10 fg on-column for reserpine (ESI+, 400 µL/min)
ResolutionUnit mass resolution (±0.13 u at full width at half maximum)
Accurate Mass Capability±0.13 u (calibrated, external standard)
Ionization SourcesTurbo V™ ESI/APCI dual-mode source with rapid switchable probe
Collision CellLinear Accelerator (LINAC™) collision cell
DetectorDigital Pulse Detection System with >5-decade dynamic range
SoftwareAnalyst® 1.7.2 or later (21 CFR Part 11 compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAB API 4000
Instrument TypeTriple Quadrupole (QqQ) with Linear Accelerator (LINAC) Collision Cell
Mass Range10–3000 Da
SensitivityS/N ≥ 100:1 for 1 pg on-column reserpine (ESI+)
Resolution0.5–0.7 Da (FWHM)
Mass Accuracy±0.1 Da
Ionization SourcesTurboIonSpray® and APCI® (plug-and-play interchangeable probes)
Vacuum SystemDual-stage air-cooled turbomolecular pumps
Dimensions (H×D×L)52 × 50 × 130 cm
Operating Environment15–30 °C, 208–240 V AC, High-Purity Nitrogen & Zero-Air
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTSQ Quantum Ultra
Mass Range10–3000 m/z
SensitivityS/N ≥ 100:1 (1 pg reserpine, SRM mode)
Resolution0.5–0.7 m/z (FWHM)
Mass Accuracy±0.1 Da (typical under calibrated conditions)
ConfigurationRefurbished, fully validated, factory-reconditioned system with dual ESI/APCI source
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
Instrument TypeTriple Quadrupole / Linear Ion Trap Hybrid System
Model3200 Q-TRAP
Mass Range5–2,000 m/z (typical operational range)
SensitivitySub-pg on-column for small molecules (e.g., <10 fg injected for reserpine S/N ≥ 50:1 in MRM)
ResolutionUnit mass resolution in both Q1 and Q3
Accurate Mass CapabilityNot applicable (non-high-resolution system)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Instrument TypeTandem Quadrupole (Triple Quadrupole)
Mass Rangem/z 10–3000
Quantitative CapabilityUp to 3000 Timed-SRMs per run
Polarity Switching Time≤25 ms
H-SRM Dwell Time2 ms
Ion SourceThermo Scientific Ion Max with HESI-II Probe
SoftwareThermo Scientific TraceFinder and/or QuanBrowser (v5.0+)
ComplianceDesigned for GLP/GMP environments
Show next