Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelGM-0.50
Instrument TypeCirculating Water-Free Vacuum Pump
Product TypeOil-Free Diaphragm Pump
Flow Rate30 L/min
Ultimate Vacuum Pressure≤ −0.08 MPa (≤ −80 kPa)
Positive Pressure Output≥ 0.03 MPa (≥ 30 psi)
Noise Level< 55 dB(A)
Inlet/Outlet Port DiameterØ6 mm
Dimensions (W×D×H)215 × 165 × 270 mm
Motor Power120 W, Single-Phase
Operating Temperature Range7–40 °C
Weight8 kg
CoolingIntegrated Self-Cooling Exhaust System
Membrane MaterialFluoroelastomer (FKM)
BearingImported High-Precision Ball Bearings
ComplianceCE-marked design principles
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelMCP1
PriceUSD 85
Plate Capacity10
Pipetting Accuracy±2% at 10 µL
Pipetting Volume Range10–10,000 µL
Sample Throughput5 samples per run
Dimensions (W×D×H)70 × 80 × 90 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
Model1810C
PriceUpon Request
Input WaterMunicipal tap water (high hardness), 1.0–5.0 kg/cm² pressure, 5–40 °C
Power Supply220 V / 50 Hz, 80 W
Ambient Operating Conditions5–40 °C, 10–80% RH
Production Rate10 L/h
Continuous Dispense Flow1.5 L/min
Type III Water Conductivity<10 µS/cm (meets GB/T 6682–1992 Grade III & ASTM CAP/NCCLS standards)
Type I Water Resistivity18.25 MΩ·cm @ 25 °C (meets GB/T 6682–1992 Grade I & ASTM CAP/NCCLS standards)
TOC<10 ppb
Silica Rejection>99.9%
UV Absorbance (254 nm, 1 cm path)≤0.001
Soluble Silica (as SiO₂)<0.01 ppm
Particles (>0.22 µm)<1 /mL
Heavy Metals (total)<0.01 ppm
Cationic Impurities (Fe, Cu, Al, Ni, Zn, Cr, Na, K)<0.001–0.02 ppb
Anionic Impurities (Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻)<0.01–0.02 ppb
Display4-line color LCD
HousingMatte black ABS
ControlTouch keypad with self-diagnostic boot sequence
Integrated FunctionsAuto-flush timer, RO antiscalant algorithm, manual RO flush, low-water alarm, power-fail safeguard, full-tank standby mode, real-time resistivity monitoring, manual recirculation, scheduled ultrapure water recirculation
Purification PathwayTap water → Pre-filter → Water softener → Coarse filter → Fine filter → Activated carbon filter → Booster pump → RO membrane → Pure water tank → Membrane pump → Ultra-purification cartridge → Final 0.22 µm terminal filter → Type I outlet / Type III outlet
Accessories30 L polyethylene pure water storage tank
DocumentationUser manual, installation guide, maintenance manual, warranty card
ServiceOn-site commissioning, system validation, and operator training included
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (Kyocera-branded distribution)
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelJK-2L (2 L/min) / JK-5L (5 L/min)
Air PurityOil-Free, Triple-Stage Purification
Output Flow Rate0–2 L/min (JK-2L) / 0–5 L/min (JK-5L)
Output Pressure0–0.4 MPa (for GC instruments) or 0–0.5 MPa (for air inlet of nitrogen generators)
Noise Level≤42 dB(A)
Power Supply220 V, 50 Hz
Operating Temperature15–40 °C
Relative Humidity≤70% RH (non-condensing)
Rated Power150 W
Dimensions (L×W×H)490 × 240 × 380 mm
Weight23 kg
Safety FeaturesDual-stage pressure relief protection, thermal cut-off control, manual drain valve
Filtration StagesPre-filter + activated carbon chamber + color-indicating silica gel chamber
Regulatory ComplianceDesigned for GLP-compliant laboratory environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelWelch DV-58
PriceAvailable Upon Request
Max Vacuum Level2 Torr
Max Flow Rate58 L/min
ConstructionPTFE-Coated Gas Path
Noise Level<45 dB(A)
PortabilityBenchtop, Compact Footprint
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRD
OriginUSA
ModelCH2-500
Hydrogen Generation PrinciplePure Water Electrolysis
Output Flow Rate500 mL/min (up to 1300 mL/min customizable)
Output Pressure11.9 bar (0–100 PSI / 0–0.7 MPa)
Hydrogen Purity99.999995%
Power Supply220 V, 50 Hz
Dimensions40 × 40 × 45 cm
Weight23 kg
CertificationsCSA, UL, IEC 61010, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyocera
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelJUPT-IV Series
QuotationAvailable Upon Request
Control InterfaceTouch-key with LCD display
Safety FeaturesLow-water alarm, power-failure protection
RO SystemIntegrated anti-scaling program + manual RO membrane flush button
Control CoreIC-based microcomputer controller
MonitoringReal-time online water quality monitoring
Dual-Outlet DesignGrade III purified water + Grade I ultrapure water
Auto-StopFull-tank shutdown
Auto-StartActivated by inlet supply or user demand
UV SterilizationDual-wavelength (185 nm + 254 nm) UV lamp with TOC reduction capability
Final Filtration0.45 µm / 0.22 µm pre-filtered high-flux terminal filter
Pre-desalinationTwo-stage pre-desalting system (optional for high-TDS feedwater)
ScalabilityUpgradable for enhanced water quality and flow capacity
Feed WaterMunicipal tap water, pressure 0.1–0.5 MPa
RO Production Rate5–20 L/h
Continuous Dispensing Flow1.5 L/min
Grade III Water Conductivity2–10 µS/cm (meets GB/T 6682–1992 Class III & ASTM CAP/NCCLS standards)
Grade I Ultrапure Water Resistivity≥18.20 MΩ·cm @ 25 °C (meets GB/T 6682–1992 Class I & ASTM CAP/NCCLS standards)
Silica Rejection Rate>99.9%
Absorbance (254 nm, 1 cm path)≤0.01
Soluble Silica [as SiO₂]<0.01 ppm
Particles (>0.22 µm)<1/mL
Power Supply220 V AC, 50 Hz
Operating Environment5–40 °C
Optional AccessoriesSediment pre-filter, water softener (for hardness >200 mg/L as CaCO₃), desalinator (for TDS >400 ppm)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelSolvent Filtration System with Diaphragm Vacuum Pump
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelMolelement 1810v
PricingAvailable Upon Request
Feed WaterDistilled or RO Water (5–40 °C)
Continuous Flow Rate1.5 L/min
Production Rate10 L/h
Resistivity18.25 MΩ·cm @ 25 °C
TOC<10 ppb
Silica Rejection>99.9%
UV Absorbance (254 nm, 1 cm)≤0.001
Particles (>0.22 µm)<1 /mL
Heavy Metals<0.01 ppm (max)
Cation Limits (ppb)Fe <2, Cu <2, Al <3, Ni <1, Zn <5, Cr <1, Na <20, K <20
Anion Limits (ppb)Cl⁻ <10, NO₂⁻ <20, NO₃⁻ <20, SO₄²⁻ <10
Compliant WithGB/T 6682–1992 Grade I, ASTM D1193–2020 Type I, NCCLS/CLSI EP21-A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRDA
OriginUSA
ModelCH2-260
Hydrogen Generation PrinciplePure Water Electrolysis
Output Flow Rate260 mL/min
Output Pressure11.9 bar
Hydrogen Purity99.999995%
CertificationsCSA, UL, IEC 61010, CE
Dimensions40 × 40 × 45 cm
Weight23 kg
Power Supply220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelCWY-3KVA
Unit PriceUSD 495 (FOB)
Rated Capacity3 kVA
Phase ConfigurationSingle-Phase
Net Weight106 kg
Dimensions (W×D×H)510 × 365 × 695 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelMultiwave 3000
PriceUSD 14,000 (FOB)
Cavity ClassIndustrial-Grade
Sample Capacity48-position rotor
Microwave SourceDual 2D Magnetron (1400 W, non-pulsed)
Max Temperature300 °C
Max Pressure1500 psi
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelJK-500Y
PriceUSD 420 (approx.)
Input Voltage220 V AC, 50/60 Hz
Oxygen Purity99.995 %
Output Flow Rate0–800 mL/min
Output Pressure0.4 MPa (customizable upon order)
Max Power Consumption500 W
Operating Temperature0–40 °C
Relative Humidity<85 % RH
Dimensions (L×W×H)520 × 280 × 400 mm
Weight~35 kg
ElectrolyteDeionized/Distilled Water
Electrolysis Voltage<2.3 V per cell
CoolingPassive thermal management via low-voltage high-current electrolysis architecture
SafetyIntegrated one-way valve to prevent backflow/liquid carryover
Gas DryingBuilt-in desiccant-based drying chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRD
OriginUSA
ModelCH2-160
Hydrogen Generation PrinciplePEM Electrolysis of Deionized Water
Purity99.999995%
Max Flow Rate160 mL/min
Max Outlet Pressure0–100 psi (0.7 MPa)
Power Supply220 V, 50 Hz
Dimensions40 × 40 × 45 cm
Weight23 kg
CertificationsCSA, UL, IEC 61010, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJKRD
OriginUSA
ModelCGH2-160
Hydrogen Production PrinciplePure-water electrolysis
Output Flow Rate160 mL/min (up to 1300 mL/min customizable)
Output Pressure11.9 bar (0–100 psi)
Hydrogen Purity99.999995%
Dimensions40 × 40 × 45 cm
Weight23 kg
Power Supply220 V, 50 Hz
CertificationsCSA, UL, IEC 61010, CE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (Kyocera-branded distribution)
OriginBeijing, China
ModelJK-300N / JK-500N
Nitrogen Generation PrinciplePressure Swing Adsorption (PSA) from Compressed Air
Output Flow0–300 mL/min (JK-300N) / 0–500 mL/min (JK-500N)
Output Pressure0.4 MPa
Nitrogen Purity99.9994% (v/v, O₂-equivalent basis)
Dew Point–10 to –40 °C
Input Air Pressure≥ 0.5 MPa
Power Supply220 V AC, 50 Hz
Max. Power Consumption80 W (JK-300N) / 100 W (JK-500N)
Dimensions (L×W×H)360 × 190 × 380 mm
Weight15 kg (JK-300N) / 16 kg (JK-500N)
Operating Ambient10–40 °C, RH < 85%, non-corrosive, low-dust environment
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandJingke Ruida (Kyocera)
OriginBeijing, China
ModelJK-300H / JK-500H
Purity≥99.999% H₂ (O₂-equivalent basis)
Output Pressure0.3 MPa (factory-set, non-adjustable in field)
Flow Rate0–300 mL/min (JK-300H) / 0–500 mL/min (JK-500H)
Power SupplyAC 220 V, 50 Hz
Max. Power Consumption180 W
Operating Temperature0–40 °C
Relative Humidity<85% RH (non-condensing)
Dimensions (L×W×H)360 × 190 × 380 mm
Weight7 kg (JK-300H) / 8 kg (JK-500H)
ElectrolyteDeionized or distilled water only]