Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPersee
ModelTAS-990
OriginImported (Manufactured in China, Designed to International AAS Standards)
ConditionProfessionally Refurbished & Fully Recertified
Price RangeUSD 2,800 – 4,200 (FOB Beijing)
Optical SystemDouble-beam, Hollow Cathode Lamp-based AAS with Deuterium Background Correction
Detection TechniqueFlame Atomic Absorption Spectrometry (FAAS)
Wavelength Range190–900 nm
Spectral Bandwidth0.1/0.2/0.4/1.0/2.0 nm Adjustable
DetectorLow-noise Photomultiplier Tube (PMT)
Flame SystemAir-Acetylene & Air-Propane Compatible
Safety ComplianceMeets IEC 61010-1 for Laboratory Electrical Safety
SoftwarePersee AAWin v3.2 with Audit Trail, User Management, and Data Export (CSV, PDF, XML)
Regulatory AlignmentSupports GLP/GMP documentation workflows per FDA 21 CFR Part 11 requirements (electronic signature enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelAgilent 7500 ICP-MS
Price RangeUSD 32,000 – 38,500 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelICS-1000
PriceNegotiable (USD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDionex
OriginUSA
Manufacturer TypeAuthorized Distributor
CategoryImported Instrument
ModelICS-3000
PriceUSD 21,500 (approx. based on ¥150,000 at 1 USD = ¥6.97)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelAA-6300
Instrument TypeFlame and Graphite Furnace Atomic Absorption Spectrometer (Configurable)
ComplianceDesigned to meet ISO/IEC 17025 laboratory requirements for elemental analysis
SoftwareShimadzu AA Solution software (v3.x or later, compatible with Windows 10/11)
Detection PrincipleAtomic absorption spectroscopy based on hollow cathode lamp (HCL) excitation and monochromator-based wavelength isolation
Typical Detection LimitsSub-pptr (ng/L) for graphite furnace mode
Wavelength Range190–900 nm
Spectral Bandwidth0.2, 0.7, 1.3, 2.0 nm selectable
Lamp Ports6-position automatic lamp turret
Safety CertificationsCE-marked, compliant with IEC 61010-1 for laboratory electrical safety
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelOptima 2100 DV
ConfigurationDual View (Radial + Axial) ICP Optical Emission Spectrometer
Instrument StatusRefurbished & Fully Qualified Used System
ComplianceMeets ASTM D1976, ISO 11885, EPA Methods 200.7 & 6010D Requirements
SoftwareWinLab32 v4.1 with Full Audit Trail & 21 CFR Part 11 Ready Configuration
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0