Empowering Scientific Discovery

Beijing Jingkeruida Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 1100 Series
Instrument TypeLiquid Chromatograph
Operational Age2–3 years
Warranty6 months
ConfigurationComplete system (pump, autosampler, column oven, UV-Vis detector, degasser, controller)
ComplianceFully refurbished to meet Agilent’s pre-owned equipment standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-20A
Instrument TypeHPLC System
Age Range5–8 years
Warranty1 year
CategorySecond-hand Analytical Instrument
ComplianceImport-class, CE-marked configuration (as supplied)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
Model2695
Product CategoryChromatography
Operational Age2–3 Years
Warranty6 Months
Price RangeUSD 8,200 – 11,000 (FOB China Port)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelWFX-120B
PriceUSD 4,200 (FOB Beijing)
Product CategoryOptical Spectroscopy
Operational Age6–8 years
Warranty6 months limited parts & labor
Instrument TypeFlame AAS
Flame Temperature Range2300–2950 °C (adjustable)
Wavelength Range190–900 nm
Grating Density1800 lines/mm
Focal Length277 mm
Blazed Wavelength250 nm
Spectral BandwidthMulti-step automatic switching
Atomizer10 cm single-slit titanium burner
NebulizerMetal-sheathed high-efficiency glass nebulizer
Sample Uptake Rate6–7 mL/min
Background CorrectionD₂-lamp (≥30× at 1 Abs) and Self-Reversal (≥30× at 1.8 Abs)
DetectorWide-spectral-range photomultiplier tube (PMT)
Lamp System6-position auto-switching turret (2 positions compatible with high-performance hollow cathode lamps)
Lamp Current Drive400 Hz square-wave pulse
Software PlatformWindows 98/Me/XP native BRAIC application suite
Data OutputRS-232 interface
Dimensions (W×D×H)1020 × 490 × 540 mm
Weight80 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-2010CHT
Instrument CategoryHPLC System
Solvent DeliveryDual-plunger parallel pump (main piston 10 µL, auxiliary piston 5 µL)
Flow Rate Range0.001–5.0 mL/min (at 1–35 MPa)
Flow Accuracy±1% (at 1 mL/min, 3–10 MPa, water, 20 °C)
Flow Precision≤0.075% RSD or ≤0.02 min SD (whichever is greater
Pressure Accuracy±2% or ±0.5 MPa (whichever is greater)
Gradient Capability4-solvent low-pressure mixing
Gradient Composition Range0–100% in 0.1% increments
Gradient Accuracy±0.5% (acetone/water, binary, 0.1–2 mL/min, 1–20 MPa)
Gradient Precision±0.1% (same conditions)
DegasserMembrane-based online degassing, 5 channels (4 for mobile phase, 1 for autosampler wash solvent)
AutosamplerInjection volume 0.1–100 µL (standard), up to 2000 µL (optional)
sample capacity350 × 1 mL vials, 140 × 1.5 mL vials, or 100 × 4.0 mL vials
injection repeatability<0.3% RSD (10 µL)
carryover<0.01% (naphthalene test)
injection accuracy±1% (50 µL, n=6)
max. injections per sample99
run time range0.01–9999.9 min (0.01-min increment)
programmable stepsup to 202
Column OvenPeltier-heated/cooled
temp. control range15 °C below ambient to 60 °C
stability±0.1 °C
UV-Vis DetectorDeuterium lamp source
wavelength range190–600 nm
bandwidth8 nm
wavelength accuracy±1 nm
wavelength precision±0.1 nm
drift≤1 × 10⁻⁴ AU/h (250 nm, empty cell)
noise≤±0.25 × 10⁻⁵ AU (250 nm, empty cell, 1 s time constant)
flow cell path length10 mm (8 µL standard), 5 mm (2.4 µL semi-prep)
dual-wavelength detectionany two wavelengths from 190–370 nm and 371–600 nm
Sample CoolerDirect-cooling type
temperature setpoint4–40 °C
System ControllerIntegrated system controller with embedded software interface
Warranty6 months
Operational Age≥7 years
ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-2030
Maximum Operating Pressure44 MPa
Sample Tray Capacity100 positions with refrigerated autosampler (4–10 °C)
Detector TypeUV-Vis (standard), optional PDA/FLD/RID compatibility
Column OvenIntegrated, temperature-controlled (5–85 °C)
Software PlatformLabSolutions (including LabSolutions GPC module for polymer analysis)
Warranty12 months
Service HistoryFully refurbished and performance-verified
Instrument Age3–4 years
ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelTurboMatrix 16
Sample Capacity16 positions
Oven Temperature Range35–210 °C (1 °C increments)
Maximum Vial Heating Temperature210 °C
Minimum Ambient Operating Temperature15 °C
Maximum Ambient Operating Temperature32 °C
Dimensions (W × H × D)43.0 × 61.0 × 50.8 cm
Weight32.0 kg
Calibration & PerformanceRSD ≤1.5% for 0.4% aqueous ethanol
Injection ModesPressure-balanced static headspace, trap-enriched headspace, multiple headspace extraction (MHE), and auto-overlap heating (up to 12 vials)
Gas Control OptionsManual pressure control (0–60 psig) or electronic pneumatic control (PPC)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Instrument TypeTriple Quadrupole LC-MS/MS
ModelTSQ Quantum Access
Mass Analyzer ConfigurationTriple Quadrupole
Detection PrincipleElectrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry (MS/MS)
Typical Service Life6–8 years
Warranty6 months
Regulatory Compliance ContextDesigned for GLP/GMP-aligned workflows
Software PlatformXcalibur (v2.2 or later)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAB5500
Instrument Age10 years
CategoryUsed Liquid Chromatography–Tandem Mass Spectrometer (LC-MS/MS)
Compliance ContextDesigned for GLP/GMP-regulated environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Instrument TypeUltra-Performance Liquid Chromatograph
ModelACQUITY UPLC
Age Range5–8 years
Warranty6 months
Regulatory ComplianceDesigned to support GLP/GMP workflows
Software PlatformEmpower 3 (or compatible legacy version)
Flow Rate RangeUp to 2 mL/min
Pressure RatingUp to 15,000 psi
Detection CompatibilityUV/Vis, PDA, or MS interfaces (system-dependent configuration)
Column Temperature ControlAmbient to 90 °C
Injection Precision≤ 0.3% RSD (typical, with standard autosampler)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-2010AHT
ConfigurationIntegrated HPLC System with Solvent Degasser, Low-Pressure Gradient Unit, Dual-Piston Pump, Autosampler with Refrigerated Sample Cooler, Column Oven, and UV-Vis Detector
Flow Rate Range0.001–5.0 mL/min (up to 35 MPa)
Gradient Accuracy±0.5% (binary system)
Autosampler CapacityUp to 350 × 1 mL vials
Detection Wavelength Range190–600 nm
Temperature Control Range (Column Oven)15 °C below ambient to 60 °C
Warranty6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelEvolution 300
Optical DesignDouble-beam with Ebert monochromator
Light SourceXenon lamp
DetectorDual photodiode array
Spectral Range190–1100 nm
Spectral Bandwidth0.5, 1.0, 1.5, 2.0, 4.0 nm
Wavelength Accuracy±0.3 nm (typical ±0.1 nm)
Wavelength Repeatability±0.1 nm (typical ±0.03 nm)
Photometric Range–3 to +6 A
Stray Light<0.0001% T at 220 nm (using NaI)
Absorbance Linearity±0.002 A (0–2 A), ±0.005 A (2–4 A), ±0.01 A (4–6 A)
Baseline Flatness±0.0008 A (200–800 nm)
Sample CompartmentMotorized 6-position cuvette holder with auto-sensing
ComplianceASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 (with VISIONsecurity), GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 7890A-7000B
Instrument TypeTriple Quadrupole Gas Chromatography–Mass Spectrometry (GC-MS/MS) System
Operational Age6–8 years
Warranty6 months
CategorySecond-hand Analytical Instrument
ComplianceDesigned to meet ASTM D5845, EPA Method 8270/1613/1631, and ISO/IEC 17025-aligned laboratory practices
Software PlatformMassHunter Workstation (vB.08.x or later, validated for GLP environments)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAgilent 7890A GC / 7000A Triple Quadrupole MS
Product CategoryMass Spectrometer
Operational Age6–8 years
Warranty12 months
Instrument ConfigurationGas Chromatograph coupled with Triple Quadrupole Mass Spectrometer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJingke Ruida (JKRD)
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSP7800
Warranty12 months
Product CategoryChromatography Instrument
Instrument TypeGas Chromatograph
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelQuattro Micro
Instrument TypeTriple Quadrupole Gas Chromatography Tandem Mass Spectrometer (GC-MS/MS)
ConfigurationBenchtop
Ionization SourcesESI, APCI, ESCi
Mass Range5–3,000 m/z
Scan SpeedUp to 5,000 amu/s
Interface TechnologyZ-Spray™ ion interface
Typical Service Life6–8 years
Warranty6 months post-installation
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
ModelZQ-2000
Mass Range2–2000 Da (extendable to 4000 Da)
Sensitivity1 pg reserpine, S/N ≥ 50:1 (ESI+, full scan)
Ionization ModesESI and APCI with rapid polarity switching
InterfaceMKII Z-Spray orthogonal interface compatible with volatile buffers
Built-in syringe pumpsoftware-controlled, flow range 1–500 µL/min
DetectionPositive/negative ion mode switching in < 1 s
SoftwareMassLynx 4.x with QuanLynx and MaxEnt1 modules
Warranty6 months limited hardware warranty
Operational Age2–3 years
ConfigurationStandalone LC/MS system compatible with Waters Alliance 2695/2795 HPLC platforms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-2030C (3D)
Maximum System Pressure44 MPa
Sample Capacity100-position autosampler with refrigerated sample tray (4–10 °C)
Detector TypePhotodiode Array (PDA) Detector
Column OvenIntegrated, temperature-controlled (5–85 °C)
Software PlatformLabSolutions (v5.9 or later)
Warranty12 months
Operational Age3–4 years
ComplianceDesigned to support GLP/GMP workflows with audit trail-capable data handling (FDA 21 CFR Part 11 readiness via LabSolutions optional modules)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCIEX
OriginUSA
ModelAPI4000
Instrument TypeTriple Quadrupole Liquid Chromatography-Tandem Mass Spectrometer
Application DomainQuantitative Bioanalysis, DMPK, Clinical Research, Impurity & Metabolite Identification
ConditionFactory-Refurbished
Operational Age6–8 years
Warranty12 months comprehensive coverage
Regulatory Compliance SupportFDA 21 CFR Part 11–ready software configuration, GLP/GMP-aligned audit trail capability
Ionization ModesTurboIonSpray®, APCI, optional DuoSpray™ and PhotoSpray™ sources
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAgilent 7800 ICP-MS
Price RangeUSD 32,000 – 45,000 (FOB)
Product CategoryMass Spectrometer
Operational Age6–8 years
Warranty12 months
Instrument TypeICP-MS
ComplianceMeets original Agilent factory specifications for performance verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelAgilent 7500
Product CategoryMass Spectrometer
Instrument Age6–8 years
Warranty1 year
ConditionRefurbished & Fully Qualified for Routine Lab Use
ComplianceMeets original Agilent factory specifications for sensitivity, background, and stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelL-3530
Detection PrincipleEvaporative Light Scattering
Light SourceHigh-Efficiency LED (470 nm)
DetectorHigh-Sensitivity Photomultiplier Tube (PMT)
Evaporation Temperature RangeAmbient to 100 °C (1 °C increments)
Flow Rate Compatibility0.1–2.5 mL/min (standard)
Nebulizing GasNitrogen or compressed air (≥5 L/min, 2–4.5 bar)
Gas Consumption<3.0 L/min
Baseline Noise<1×10⁻³ AU/hr (aqueous) / <3×10⁻³ AU/hr (non-aqueous)
Detection Limit<5 ng (caffeine)
Quantitation Range0.5–5 µg
Dimensions550 × 250 × 480 mm (D×W×H)
Power Supply115 V AC, 60 Hz, 1.8 A or 230 V AC, 50 Hz, 1.7 A
Age3–4 years
Warranty2 years
CategorySpectroscopic Detector for HPLC Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelLC-10A
Instrument CategoryChromatography
Age2–3 years
Warranty6 months
Manufacturer TypeAuthorized Distributor
Import StatusImported
Price RangeUSD 2,800 – 4,900 (FOB China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ModelTSQ Quantum Access MAX
Mass Rangem/z 10–3000
Resolution≥10,000 (FWHM)
H-SRM Dwell Time<2 ms
Polarity Switching Time<25 ms
Scan Speed5000 u/sec (full range)
Mass Stability±0.050 amu/24 h
Sensitivity (ESI/APCI)1 pg reserpine, S/N >200:1 (peak-to-peak)
Ion SourceH-ESI II & APCI
Vacuum SystemThree-stage oil-free turbomolecular pumps (400 L/sec in Q2 region)
Detection±15 kV post-acceleration, 90° electron multiplier
SoftwareLC Quan 2.5, QED-MS/MS™, RER™, real-time isotope correlation, dynamic exclusion, >700-compound LC/MS/MS spectral library