- All
- Favorite
- Popular
- Most rated
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | Mi2 |
| Instrument Type | Online |
| Detection Principle | Electrostatic Detection with Integrated Heated Sampling |
| Particle Size Range | ~1 nm – 2.5 µm |
| Mass Concentration Range | 1 µg/m³ – 250 mg/m³ (at T = −20°C to +700°C) |
| Number Concentration Range | 10² – 10⁸ particles/cm³ (derived) |
| Sampling Frequency | 100 Hz (24-bit ADC) |
| Response Time | ≤ 0.2 s |
| Heated Sampling Line | 2 m, maintained at 200 °C |
| Operating Ambient Temperature | −20 °C to +55 °C |
| Power Supply | 24 VDC / 16 A (Mi2 unit) |
| Dimensions (L×W×H) | 798 × 484 × 208 mm |
| Weight | ~29 kg |
| Display | 4-inch color touchscreen |
| Outputs | 4-channel 4–20 mA analog |
| Interface | USB for PPS software connectivity |
| Auto-zero function | Yes |
| Compliance | Designed for EN 16454, ISO 8502-12, and EPA Method 202–compatible deployment in regulatory-grade exhaust monitoring |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | AFM1600D |
| Measurement Range | 0–25% O₂ |
| Accuracy | ±0.2% absolute |
| Calibration | ambient air (20.95% O₂) |
| Output | 0–5 V linear analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −20 to +85 °C |
| Sensor Thread | M18×1.5 |
| Dimensions | 68 mm × 32 mm × 100 mm |
| Weight | 125 g |
| Sensor Type | Bosch LSU 4.2 wideband lambda sensor |
| Cable Length | 3 m |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOx/NH3 5241 |
| Detection Principle | Electrochemical Sensing |
| Measurement Range | NOx/NO/NO₂: 0–5000 ppm |
| NH₃ | 0–2000 ppm (λ > 1 only) |
| O₂ | 0–25% vol |
| λ | 0.4–25 |
| AFR | 6–364 |
| φ | 0.04–2.5 |
| Accuracy | NOx/NO/NO₂/NH₃: ±5 ppm (0–1000 ppm), ±1% FS (other) |
| O₂ | ±0.2% abs |
| λ/AFR/φ | ±0.8% at stoichiometric, ±1.8% avg |
| Response Time | <1 s (NOx/NO/NO₂/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Operating Temperature | –40°C to +85°C (electronics), up to 950°C (sensor tip) |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six 0–5 V linearized channels |
| Communication | High-speed CAN (configurable protocol) |
| Sensor Interface | M18×1.5 threaded probe |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, extendable to 100 m |
| Optional Accessories | Pressure compensation kit, mounting bracket, calibration station, NOx/NH₃ sensor simulator, extended cable, AC/DC adapter |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS200 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | < ±2% of full scale |
| Response Time (T90) | < 5 s |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda 5220 |
| Type | Online Analyzer |
| Detection Principle | Electrochemical (Zirconia-based Wideband Sensor) |
| Max. Permissible Error | ±0.5% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±1% FS/24h |
| Repeatability | ±0.2% FS |
| Measurement Ranges | λ 0.4–25, AFR 6–364, Φ 0.04–2.5, O₂ 0–25% vol, Pressure 0–517 kPa (optional) |
| Accuracy | λ ±0.005 (at λ=1), ±0.008 (λ=0.8–1.2), ±0.009 (elsewhere) |
| Response Time | <150 ms (t₉₀) |
| Operating Temperature | −40 °C to +85 °C |
| Power Supply | 11–28 VDC |
| Analog Outputs | Six isolated 0–5 V linearized channels |
| Communication Interfaces | CAN 2.0B (user-configurable protocol), USB, RS-232 |
| Sensor Interface | M18×1.5 (Lambda probe), 1/4" NPT (pressure transducer) |
| Max. Cable Length | 100 m (sensor to analyzer) |
| Fuel Composition Parameters | Adjustable H:C, O:C, N:C, H₂ ratios |
| Compliance | Designed for R&D and production environments requiring traceable calibration per ISO/IEC 17025 practices |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | EGR 5230 |
| Instrument Type | Online Analyzer |
| Detection Principle | Electrochemical Sensing |
| Maximum Permissible Error | ±0.5% |
| Repeatability | 0.5% |
| Measurement Range | EGR 0–100% |
| Response Time | <1 s (%EGR) |
| Output | 6-channel linearized 0–5 V analog |
| Power Supply | 11–28 VDC |
| Operating Temperature | −40 °C to +85 °C |
| Sensor Mounting | 18 mm × 1.5 mm threaded O₂ sensors |
| Dimensions | 105 mm (W) × 64 mm (H) × 165 mm (D) |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Cable Length | Standard 4 m, optional up to 100 m |
| Brand | SAXON |
|---|---|
| Origin | Germany |
| Model | DPM1.0 |
| Instrument Type | Aerosol Detector |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 40 nm – 10 µm |
| Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Repeatability | ≤ ±3% |
| Accuracy | ≤ ±5% of full scale up to 150 mg/m³ |
| Exhaust Gas Temperature Limit | < 800 °C |
| Probe Melting Point Limit | < 70 °C |
| Sampling Probe | 400 mm flexible stainless-steel probe with 2 m heated sampling line |
| Response Time (T90) | < 15 s (with 2 m heated line) |
| Heating Time | < 10 min |
| Zero Calibration Time | 20 s |
| Built-in Functions | Automatic zero adjustment, internal data logger |
| Communication Interfaces | RS232, USB, Bluetooth |
| Display | Color touchscreen |
| Language Support | English, German |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | ≤ 95% RH (non-condensing) |
| Power Supply | 230 VAC / 50 Hz, max. 250 VA (including probe) |
| Dimensions (W×H×D) | ~190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCAN |
| Input Channels | Up to 8 lambda sensors + up to 8 optional pressure sensors |
| Lambda Range | 0.40–25 |
| AFR Range | 6.0–364 |
| O₂ Range | 0–25% |
| Pressure Range (optional) | 0–517 kPa |
| Lambda Accuracy | ±0.005 at λ=1, ±0.008 at λ=0.8–1.2, ±0.009 elsewhere |
| AFR Accuracy | ±0.1 at 14.6, ±0.2 at 12–18, ±0.5 elsewhere |
| O₂ Accuracy | ±0.2 (0–2% O₂), ±0.4 (other) |
| Pressure Accuracy | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-speed CAN per ISO 11898 |
| Operating Temperature | −40 °C to +105 °C |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Module Dimensions | 145 mm × 120 mm × 40 mm |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS55-T |
| Measurement Principle | Catalytic Combustion (Flame Ionization Detection alternative configuration available per customization) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm C₃H₈ (propane-equivalent) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-sensitivity to O₂ | <±2% of full scale |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (sample line excluded) |
| Sample Flow Rate | ~220 L/h |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions | 483 mm (W) × 267 mm (H) × 500 mm (D) |
| Weight | ~26.5 kg |
| Certified Compliance | TÜV-certified per German 17. BImSchV |
| EPA Method Compatibility | Compliant with EPA Method 25A and 25B requirements for THC monitoring |
| Output Signals | 0–10 V analog, 0/4–20 mA isolated current loop |
| Status Contacts | Pre-alarm, Alarm, Range Identification, Flame-Out Indication, Calibration Mode (Zero/Gas), System Health (Pressure/Temperature/Flame Monitoring) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCAN |
| Sensor Type | NTK Ceramic NOx Sensor (1), Optional Pressure Sensor (1) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±30 ppm (0–1000 ppm), ±3% FS (other) |
| Lambda | ±0.008 (λ = 1), ±0.016 (λ = 0.8–1.2), ±0.018 (other) |
| AFR | ±0.15 (14.6), ±0.4 (12–18), ±1.0 (other) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (other) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <700 ms (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, and H₂ ratios |
| CAN Interface | High-Speed CAN per ISO 11898, User-Assignable Node ID, Multi-Module Bus Support |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Mounting | 18 mm × 1.5 mm thread (NOx), 1/4" NPT (pressure) |
| Cable Length | Standard 1 m (2 m optional) |
| Calibration | Onboard EEPROM in sensor connector for zero/span calibration data storage |
| Software | PC-based configuration, real-time control, calibration, and parameter monitoring (CAN adapter required, sold separately) |
| Optional Accessories | Analog-output display head (supports up to two NOxCAN modules) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | Lambda PRO |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensor (NTK Wideband) |
| Measurement Range | AFR 8.0–25.5 |
| Accuracy | ±1% of stoichiometric value, ±2% for non-stoichiometric conditions |
| Response Time | <150 ms |
| Calculation Interval | 2 ms |
| Fuel Compatibility | Gasoline, Methanol, and other combustible fuels (with appropriate sensor calibration) |
| Analog Output | Linearized 0–5 V DC, BNC female connector |
| SEGO Sensor Interface | Supported |
| Data Logging | Min/Max AFR and λ values |
| Power Supply | 11–28 VDC |
| Dimensions | 190.5 × 101.6 × 30.5 mm (W × H × D) |
| Weight | 340 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCA03 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Extractive In-Situ Flue Gas Analyzer |
| Measurement Accuracy | ≤ ±2% of Full Scale |
| Repeatability | Not Specified |
| Response Time | ≤10 s |
| Stability | Not Specified |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | 5240 |
| Measurement Range | NOx 0–5000 ppm, NH₃ 0–1000 ppm, O₂ 0–25% vol, λ 0.4–25, AFR 6–364, φ 0.04–2.5 |
| Accuracy | NOx ±5 ppm (0–1000 ppm), ±1% FS (other) |
| Response Time | <1 s (NOx/NH₃), <150 ms (O₂/λ/AFR/φ) |
| Output | 6 × 0–5 V analog, CAN 2.0B, USB 2.0 |
| Power | 11–28 VDC |
| Sensor Thread | M20×1.5 or M18×1.5 |
| Dimensions (H×W×D) | 64 × 105 × 165 mm |
| Weight | 676 g (main unit), 244 g (sensor module) |
| Operating Temp. | −40 to +85 °C (electronics), up to 950 °C (sensor tip) |
| Optional | Pressure compensation kit, extended cable (up to 100 m), AC/DC adapter |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | NOxCANt |
| Communication | High-Speed CAN (ISO 11898) |
| Input | 1× NTK T-type ceramic NOx sensor (18 mm × 1.5 mm thread) + optional pressure sensor (1/4" NPT) |
| Measurement Range | NOx: 0–5000 ppm (λ ≥ 1 and λ < 1) |
| Lambda | 0.40–25 |
| AFR | 6.0–364 |
| O₂ | 0–25% vol |
| Pressure | 0–517 kPa (0–75 psia) |
| Accuracy | NOx: ±20 ppm (0–1000 ppm), ±2% FS (remaining range) |
| Lambda | ±0.008 @ λ=1, ±0.016 @ λ=0.8–1.2, ±0.018 (elsewhere) |
| AFR | ±0.15 @ 14.6, ±0.4 @ 12–18, ±1.0 (elsewhere) |
| O₂ | ±0.4% (0–2% O₂), ±0.8% (elsewhere) |
| Pressure | ±5.2 kPa (±0.75 psia) |
| Response Time | <1 s (NOx), <150 ms (Lambda/AFR/O₂) |
| Fuel Composition Configurability | H:C, O:C, N:C, H₂ ratios user-definable |
| Operating Temperature | −55 °C to +125 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Cable | Standard 1 m (2 m optional) |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | PPC |
| Instrument Type | Handheld |
| Flow Rate | High-flow (5.5 L/min) |
| Concentration Range (PN) | 0–100,000,000 #/cm³ |
| Size Range (PN & LDSA) | 10 nm–1 µm |
| Size Range (PM & Dp) | 10–300 nm |
| Detection Sensitivity | 30–1,500 #/cm³ |
| Response Time | 0.2 s |
| Sampling Frequency | 10 Hz / 1 Hz / 60 s |
| Operating Temperature | 5–40 °C |
| Sample Gas Temperature | up to 600 °C |
| Heated Sensor Module | 200 °C |
| Integrated VPR | Yes |
| Power Input | 100–260 VAC, 50–60 Hz |
| Power Consumption | 140 W (steady), 1200 W (startup) |
| Dimensions | 464 × 175 × 339 mm |
| Weight | 9.1 kg (without heated sampling line) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | AFRecorder1200 |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Sensing |
| Measurement Range | AFR 6–150 |
| Accuracy | ±0.6% (stoichiometric), ±0.9% (full range) |
| Response Time | <150 ms |
| Calculation Interval | 1 ms |
| Fuel Flexibility | Configurable H:C, O:C, N:C ratios and H₂ content |
| Analog Output | Linearized 0–5 V (BNC female) |
| Digital Interface | RS232 (bidirectional) |
| SEGO Sensor Output | User-configurable |
| Data Logging | Integrated |
| Statistical Functions | Mean, Min, Max, Standard Deviation |
| Power Supply | 11–28 VDC (with 100–250 VAC/DC adapter) |
| Dimensions | 190.5 × 101.6 × 30.5 mm (W × H × D) |
| Weight | 290 g |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS53-T |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Flame Ionization Detection (FID) |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm (as propane) |
| Accuracy | ≤ ±1% of reading |
| Repeatability | < ±2% of full scale |
| Response Time | ≤ 2 s (without sampling line) |
| Stability | < ±2% of full scale (zero & span drift over 7 days: < ±2% and < ±4%, respectively) |
| Linearity | ±2% of full scale up to 10,000 ppm |
| Cross-Sensitivity to O₂ | < ±2% of full scale |
| Detection Limit | < 2% of full scale |
| Zero Drift | < ±2% FS/week |
| Span Drift | < ±4% FS/week |
| Sample Flow Rate | ~90 L/h |
| Output Signals | 0–10 V or 0/4–20 mA |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz |
| Dimensions | 360 mm × 200 mm × 500 mm |
| Weight | ~20 kg |
| Certification | TÜV-certified |
| Optional Features | ppb-range capability, heated sampling line, front-mounted particulate filter, integrated zero-air & combustion air supply, H₂ or He/H₂ fuel selector, onboard calibration gas cylinder, onboard fuel cylinder, PC communication software |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FastTEMP |
| Instrument Type | Online |
| Detection Principle | Active-Drive Thermocouple Signal Conditioning |
| Max. Permissible Error | ±1°C |
| Measurement Range | –60°C to +1370°C |
| Response Time | <50 ms (10–90%, fast mode) |
| Output | 5 mV/°C (fast & standard), output impedance <500 Ω |
| Input–Output Isolation | 200 V (sensor input to output), 500 V (power supply referenced) |
| Cold-Junction Compensation | Built-in |
| Sensor Compatibility | Grounded K-type thermocouples, minimum probe diameter 1.5 mm (1/16″), standard length 150 mm (6″) |
| Power Supply | 6–35 VDC, 200 mW |
| Enclosure Rating | IP67 |
| Operating Ambient Temp | –55°C to +125°C |
| Relative Humidity | 100% RH |
| Dimensions | 152 × 70 × 30 mm |
| Weight | 360 g |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | baroCAN |
| Sensor Inputs | 1× RH/T, 1× Absolute Pressure, 1× O₂ |
| Measurement Parameters | Relative Humidity (0–100% RH), Temperature (−40 to +125 °C), Absolute Pressure (0–500 kPa), Dew Point (0–125 °C), Water Vapor Pressure, Oxygen Concentration (0–20.946% vol), Accuracy: ±2% RH, ±0.3 °C, ±0.2 kPa, ±0.88 °C dew point, ±0.02% O₂ |
| Response Time | 1 s (RH/T/dew point/O₂), 25 ms (pressure) |
| Communication | High-Speed CAN 2.0B, ISO 11898 compliant |
| Enclosure Rating | IP67 |
| Operating Temp | −55 to +125 °C |
| Power | 6–32 VDC |
| Dimensions | 145 × 120 × 40 mm |
| Weight | 234 g |
| Threaded Ports | 1/4″ NPT/ISO for RH/T and pressure sensors |
| Configuration & Data Logging | Dedicated PC software via CAN interface |
| Brand | Ratfisch |
|---|---|
| Origin | Germany |
| Model | RS 55-T |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Measurement Principle | Catalytic Combustion (Catalytic Bead) with Propane Calibration |
| Range | 0–10 / 100 / 1,000 / 10,000 / 100,000 ppm (propane) |
| Linearity | ±2% of full scale (up to 10,000 ppm) |
| Cross-Sensitivity | ±2% of full scale @ O₂ |
| Detection Limit | <2% of lowest full-scale range |
| Zero Drift | <2% FS/week |
| Span Drift | <4% FS/week |
| Response Time (T₉₀) | ~1–2 s (without sampling line) |
| Sample Flow Rate | ~220 L/h |
| Output Signals | 0–10 V or 0/4–20 mA |
| Alarm Contacts | Pre-alarm, Main Alarm, Range Identification, Flame-Out Indication, Status Recognition (Zero Gas, Calibration Gas), Pressure/Temperature/Flame Monitoring |
| Operating Ambient Temperature | +5 °C to +35 °C |
| Power Supply | 230 V / 50 Hz, 800 W |
| Dimensions (W×H×D) | 483 mm × 267 mm × 500 mm (19″ rack-mountable) |
| Weight | ~26.5 kg |
| Certification | TÜV-certified per German 17. BImSchV |
| Regulatory Compliance | EPA-compliant methodology for odor reduction quantification |
| Brand | Pegasor |
|---|---|
| Origin | Finland |
| Model | PPS-M |
| Particle Size Range | ~nm–2.5 µm |
| Mass Concentration Range | 1 µg/m³–500 mg/m³ (dependent on sample gas temperature) |
| Number Concentration | Supported via Faraday cup current differential |
| Response Frequency | Up to 100 Hz |
| Operating Sample Gas Temperature | Standard version up to 200 °C |
| Ambient Temperature Range | −20 °C to +50 °C |
| Sample Gas Pressure | 1–10 bar (absolute) |
| Power Consumption | 6 W |
| Output Interface | USB (standard), analog output optional |
| Sensor Housing Material | Stainless steel |
| Dimensions | 400 mm (length) |
| Weight | 2.6 kg |
| Gas Inlet/Outlet | G1/4″ (inlet), G3/8″ (outlet), G1/8″ (clean air supply) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | OXY6200 |
| Measurement Range | 0.0–25.0% O₂ |
| Accuracy | ±0.1% FS |
| Response Time | <150 ms |
| Output | Linearized 1.0–5.5 V DC |
| Sensor Thread | M18 × 1.5 mm |
| Dimensions | 102 × 89 × 25 mm |
| Weight | 160 g |
| Power Supply | 11–28 VDC |
| Calibration | Ambient Air (20.95% O₂) |
| Includes | UEGO Sensor, Control Module, 3 m Cable, Mounting Sleeve & Bolt, User Manual |
| Brand | ECM |
|---|---|
| Origin | USA |
| Model | LambdaCAN |
| Interface | High-Speed CAN (ISO 11898) |
| Input | 1 lambda sensor + optional pressure sensor |
| Lambda Range | 0.40–25.0 |
| AFR Range | 6.0–364.0 |
| O₂ Range | 0–25% |
| Pressure Range (optional) | 0–517 kPa |
| Accuracy (λ) | ±0.005 @ λ=1, ±0.008 @ λ=0.8–1.2, ±0.009 elsewhere |
| Accuracy (AFR) | ±0.1 @ 14.6, ±0.2 @ 12–18, ±0.5 elsewhere |
| Accuracy (O₂) | ±0.2 @ 0–2%, ±0.4 elsewhere |
| Accuracy (Pressure) | ±5.2 kPa |
| Response Time | <150 ms |
| Fuel Composition Parameters | Configurable H:C, O:C, N:C, H₂ ratios |
| Operating Temperature | −40 °C to +105 °C |
| Dimensions | 145 mm × 120 mm × 40 mm |
| Power Supply | 11–28 VDC |
| Sensor Thread | 18 mm × 1.5 mm (lambda), 1/4" NPT (pressure) |
| Cable Length | Standard 0.6 m (1 m / 2 m optional) |
| Brand | ECM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AFM1000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Electrochemical (Wideband Lambda/UEGO Sensor) |
| Measurement Range | 8.0–18.0 AFR |
| Accuracy | ±1.5% of reading |
| Output Signal | Linearized 0–5 V DC (AFR-proportional) |
| Sensor Thread | M18 × 1.5 mm |
| Dimensions | 4″ × 3.5″ × 1″ (101.6 × 88.9 × 25.4 mm) |
| Weight | 160 g |
| Power Supply | 11–28 VDC |
| Calibration | Single-point zero calibration in ambient air |
| Kit Includes | UEGO sensor, control module, shielded cable assembly, mounting adapter sleeve, blanking plug, and user manual |
Show next