Empowering Scientific Discovery

Beijing Zolix Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelOmniFluo960
Dispersion ElementHolographic Grating
Slit Width (Spectral Bandpass)0.01–3 mm (excitation), 0.023–7 mm (emission)
Spectral Resolution≤ 0.08 nm
SensitivityWater Raman Signal-to-Noise Ratio ≥ 10,000:1 (at 350 nm excitation, 370–450 nm scan, 5 nm slit, 1 s integration)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability±0.1 nm
Focal Length320 mm
Stray Light≤ 1×10⁻⁵
Detector OptionsCR131 (cooled red-sensitive PMT, 185–900 nm), R928, R13456, H10330C-75, R5509-73
Standard Sample ChamberSAC-FLS with cuvette, powder & solid sample holders
Automated Light ShieldYes
Dark Count≤ 100 CPS (at –10°C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelSmartFluo-Pro
PriceUSD 25,000 (FOB)
Dispersive ElementHolographic Grating
Slit Width (Spectral Bandpass)5 nm
Spectral Resolution5 nm
Detection Limit<0.1 µg/L quinine sulfate in 0.1 mol/L H₂SO₄
Wavelength Accuracy±1 nm
Excitation Range200–800 nm
Emission Range200–800 nm
Excitation Monochromator200 mm focal length, Czerny–Turner configuration, low stray light design
Grating Density1800 grooves/mm @ 400 nm
Wavelength Repeatability±0.5 nm
Integration Time100 µs to 24 s
Standard Sample HolderQuartz cuvette (10 mm path length)
Dimensions (L×H×W)620 × 415 × 300 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelFlex One
PriceUSD 70,000 (approx.)
Dispersive ElementHolographic Grating & Interference Filters
Slit Width (Spectral Bandpass)0.05 nm
Optical Resolution0.1 nm
Wavelength Accuracy±0.2 nm
Spectral Range300–2200 nm (standard configuration)
Spatial Resolution<50 µm
Excitation Wavelength Options266, 325, 405, 442, 473, 532, 633, 785 nm
Detector OptionsCooled Si CCD (2000×256), PMT, Single-Point InGaAs, Cooled InGaAs Array (512×1), or Custom Detector Modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelTCSPC Plus
Instrument TypeSteady-State & Time-Resolved Fluorescence Spectrometer
Time Resolution2 / 4 / … / 33,554,432 ps
Time Channels65,535
Dead Time2 ns
Timing Jitter<10 ps
Maximum Instantaneous Count Rate500 Mcps
PMT DetectorR928P (Spectral Range: 185–900 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelMiniPL 5.0 eV
Excitation Wavelengths224 nm (5.5 eV) or 248.6 nm (5.0 eV)
Spectral Range (Standard)190–650 nm
Spectral Range (Optional)190–850 nm
Resolution (Standard)0.2 nm @ 1200 g/mm grating
Resolution (Optional)0.07 nm @ 3600 g/mm grating
DetectorHigh-sensitivity PMT
Signal ProcessingBuilt-in boxcar averager for pulsed signal integration
Sample StageManual XYZ adjustment, max. 50 mm diameter
OptionalMotorized XY scanning stage for PL mapping
Dimensions15 × 18 × 36 cm
Weight< 8 kg
Software PlatformLabVIEW-based control & spectral analysis suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State & Time-Resolved Fluorescence Spectrometer
Dispersive ElementGrating + Bandpass Filters
Integration ConfigurationGlovebox-Compatible Fiber-Coupled Optical Path (Y-Fiber Geometry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelOmniPL Series
Price RangeUSD 28,000 – 42,500
Dispersive ElementsHolographic Grating & Bandpass Filters
Slit Width (Spectral Bandpass)Adjustable, 10–2000 µm
Spectral Resolution< 0.2 nm (@ 1200 g/mm grating)
Signal-to-Noise Ratio3000:1
Wavelength Accuracy±0.2 nm
Wavelength Repeatability±0.1 nm
Excitation SourceHeCd Laser (325 nm, 20 mW)
Rayleigh Cutoff FilterOD > 6
Spectral Detection Range300–850 nm (expandable to 2500 nm)
DetectorScientific-grade, thermoelectrically cooled back-illuminated CCD (300–1000 nm)
Optional Cryogenic StageClosed-cycle cryostat, 2 K minimum operating temperature
SoftwareFully programmable acquisition protocol engine with spectral arithmetic, batch processing, and audit-trail logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Product OriginDomestic (China)
ModelRTS2-FLIM
Dispersion ElementGrating
Instrument TypeSteady-State Fluorescence Spectrometer
Spatial Resolution≤1 µm @ 100× objective, 405 nm excitation
Excitation SourcePicosecond Pulsed Lasers (375–670 nm), 50 MHz repetition rate
Time Resolution16 ps
Fluorescence Lifetime Range500 ps – 1 µs
Instrument Response Function (IRF)≤2 ns
Spectral Range200–900 nm
Microscope ConfigurationUpright research-grade microscope with epi-illumination, halogen lamp (12 V / 100 W), 5-position objective turret (10×/50×/100×), high-definition CMOS monitor camera
Scanning StageMotorized XY stage (75 × 50 mm travel, 50 nm step size, <1 µm repeatability)
Spectrograph320 mm focal length, imaging-corrected monochromator, dual input ports, CCD & slit outputs, three 68 × 68 mm gratings, wavelength accuracy ±0.1 nm, repeatability ±0.01 nm, scan step 0.0025 nm
Detector OptionsUV-VIS PMT (185–900 nm), back-illuminated deep-depletion scientific CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C cooling, QE >95%)
TCSPC ModuleTime binning down to 16 ps, dead time <10 ns, up to 65,535 time channels, instantaneous saturation count rate 100 Mcps
SoftwareOmniFluo-FM — integrated FLIM acquisition, multi-exponential decay fitting (≤4 components), IRF-aware convolutional fitting, pseudo-color mapping, histogram/contour/3D visualization, GLP-compliant data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelOmniFluo
Price RangeUSD 28,000–42,500 (FOB)
Dispersive ElementHolographic Grating
Slit Width (Spectral Bandpass)0.01–3 mm
Spectral Resolution±0.05 nm
Sensitivity>3000:1 (Water Raman S/N ≥1000:1)
Wavelength Accuracy±0.15 nm
Spectral Range200–2500 nm
Excitation Sources150 W / 500 W Xenon Arc Lamp with Monochromator (Bandwidth 0.1–30 nm)
Optional Lasers266, 325, 375, 405, 442, 532, 785, 1064 nm
Detector OptionsCooled CCD (2000×256, 200–1000 nm), Cooled InGaAs Array (512×1, 800–2200 nm), PMT (200–870 nm), Cooled Single-Element InGaAs (800–2500 nm)
Signal ProcessingPhoton Counting or Lock-in Amplification
Optional ModulesQuantum Yield Measurement, Electroluminescence (EL), Cryogenic Sample Stage (≤10 K)
Emission Spectrum CorrectionBuilt-in Absolute Intensity Calibration Function
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelOmniFluo Series
Price RangeUSD 28,000 – 43,000 (FOB)
Dispersive ElementHolographic Grating & Interference Filters
Slit Width (Spectral Bandpass)Adjustable, 0.1–5.0 mm
Spectral Resolution0.1 nm (FWHM @ 546.1 nm)
Sensitivity3000:1 (Signal-to-Noise Ratio, RMS, water Raman peak at 350 nm excitation, 5 nm bandwidth, 1 s integration)
Wavelength Accuracy±0.2 nm (Emission), ±0.25 nm (Excitation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State & Time-Resolved Fluorescence Spectrometer
Dispersive ElementsHolographic Grating + Bandpass/Notch Filters
Excitation SourcesCW Laser Diode, Pulsed Laser (ns–ps range), Electrical Probe Station (for e-pumped lasing)
Detection ModeConfocal Micro-Spectroscopy with Back-Illuminated CCD or EMCCD
Spatial ResolutionDiffraction-Limited (~300 nm lateral at 532 nm)
Spectral Range200–1100 nm (configurable)
Temporal ResolutionDown to <100 ps (with TCSPC option)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelOmni-fs-TA
Instrument TypeTransient Absorption Spectrometer
Temporal Resolution1.5 × Laser Pulse Width
Sensitivity0.1 ΔmOD (broadband), 0.01 ΔmOD (single-wavelength)
Pump Wavelength Ranges240–480 nm, 475–1160 nm, 1160–1600 nm, 1600–2600 nm
Probe Wavelength Ranges300–700 nm
Detection Time Window4 ns / 8 ns
Laser Sources800 ± 10 nm, 1030 ± 3 nm
Sample FormatsLiquid, Powder, Thin Film
Measurement ModesTransmission, Reflection, Back-Excitation
Software FeaturesProbe Stability Monitoring, Real-Time Spectral Preview, Spectral Calibration, Smoothing, Global & Target Data Fitting
Optional ModulesMicro-area Spectroscopy, Wide-field Transient Absorption Imaging, TCSPC (2 ps min. time step, 100 ps min. lifetime range, 0.08 nm spectral resolution), Femtosecond Kerr-Gated Time-Resolved Fluorescence (400–900 nm, 50 fs pulse width, 4 ns window)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
ModelFlashSENS
PriceUSD 84,000 (FOB Beijing)
Dispersive ElementHolographic Grating
Slit Width (Spectral Bandpass)0.01–3 mm (motorized, programmable)
Spectral Resolution0.6 nm @ 300 grooves/mm
Sensitivity0.00024 OD (optical density)
Wavelength Accuracy±0.8 nm @ 300 grooves/mm
Detection Light SourceLDLS-based Supercontinuum White Light (190–2100 nm)
Time Resolution<7 ns (optional ultrafast mode: 3 ns)
Sample CompatibilitySolid films, liquid solutions, colloidal suspensions, thin-film devices
Measurement ModesTransient Absorption Kinetics (ΔA vs. t), Transient Absorption Spectra (ΔA vs. λ), Dual-mode (kinetics + spectra)
MonochromatorOmni-λ300i, 300 mm focal length
Detector OptionsSi photodiode (300–1100 nm), InGaAs array (900–1600 nm), ICCD (180–850 nm, gated, -25°C thermoelectric cooling)
Pump Laser CompatibilityNd:YAG harmonics (1064/532/355/266 nm), tunable OPO (210–2400 nm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State & Time-Resolved Fluorescence Spectrometer
Excitation Sources808 nm, 980 nm, 1064 nm, 1550 nm, 1940 nm CW lasers
Detection Range1–5.5 μm (InSb), 2–12 μm (MCT), 800–2600 nm (TE-InGaAs), 300–1700 nm (LN-PMT)
Spectral Resolution≤0.1 nm (with 320 mm Czerny-Turner monochromator & 68 mm × 68 mm gratings)
Fluorescence Lifetime Rangeμs to seconds (with TCSPC or oscilloscope synchronization)
Optical PlatformDamped vibration-isolation table (1800 × 1200 × 800 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ModelOmniPL-MicroS-A (Vertical-Path Configuration)
Price RangeUSD 14,000 – 28,000
Dispersive ElementFilter-Based Spectral Selection
Spectral Bandpass (Slit)200–1600 nm
Spectral Resolution0.1 nm
Sensitivity>100:1 (Signal-to-Noise Ratio)
Wavelength Accuracy±0.2 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State & Time-Resolved Fluorescence Spectrometer
ModelOmniFluo990
Dispersion ElementGrating
Slit Width (Spectral Bandpass)0.01–3 mm (excitation), 0.023–7 mm (emission)
Spectral Resolution0.08 nm
SensitivityWater Raman Signal-to-Noise Ratio ≥ 10,000:1
Wavelength Accuracy±0.2 nm
Lifetime Range500 ps – 10 s
Excitation SourceGloria75X 75 W Xenon Arc Lamp
Emission MonochromatorOmni-λ3027i (f = 320 mm)
Stray Light< 1×10⁻⁵
Grating Options1200 g/mm BLZ@500 nm, 600 g/mm BLZ@750 nm, 300 g/mm BLZ@1250 nm
DetectorCooled Red-Sensitive PMT CR131 (185–900 nm), Dark Count ≤ 100 CPS at –10 °C
Data AcquisitionDCS900PC TCSPC Module (Timing Resolution: 16 ps – 33.55 µs
Max Count Rate100 Mcps)
SoftwareZolixScan v4.x (Steady-State Scanning, Time-Resolved Kinetics, TRES, QY Calculation, Spectral Correction, GLP-Compliant Audit Trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelOmniFluo-FLIM Series
Dispersion ElementGrating
Instrument TypeSteady-State/Time-Resolved Fluorescence Spectrometer
Spatial Resolution≤1 µm @ 100× Objective @ 405 nm Picosecond Pulsed Laser
Spectral Range200–900 nm
Minimum Time Resolution16 ps
Fluorescence Lifetime Range500 ps – 1 µs
Instrument Response Function (IRF)≤2 ns
Excitation Sources375–670 nm Picosecond Pulsed Lasers (50 MHz Repetition Rate, Pulse Widths: 25–75 ps)
MicroscopeUpright Research-Grade with Brightfield/Darkfield Illumination, 5-Position Objective Turret (10×/50×/100×), High-Definition CMOS Monitoring Camera
XY StageMotorized, 75 × 50 mm Travel, 50 nm Minimum Step, <1 µm Repeatability
Spectrograph320 mm Focal Length, Imaging-Corrected Monochromator, Triple 68 × 68 mm Gratings, Wavelength Accuracy: ±0.1 nm, Repeatability: ±0.01 nm, Slit Width: 0.01–3 mm Motorized
Detector OptionsUV-Vis PMT (185–900 nm), Back-Illuminated Deep-Depletion CCD (2000 × 256 pixels, 15 µm × 15 µm, -60 °C Cooling)
TCSPC ModuleTime Bins Down to 16 ps, Dead Time <10 ns, Up to 65,535 Histogram Channels, Instantaneous Saturation Count Rate: 100 Mcps
SoftwareOmniFluo-FM FLIM Acquisition & Analysis Suite (Multi-Exponential Fitting ≤4 Components, IRF-Free Fitting Modes, Pseudocolor Mapping, 3D Visualization, Line/Cross-Section/Histogram/Contour Tools)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZOLIX
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelSmartFluo-QY
Dispersion ElementGrating + Interference Filters
Slit Width (Spectral Bandpass)0.1–30 nm
Spectral Resolution0.1 nm (@1200 g/mm, 435.83 nm)
Sensitivity3000:1 (Water Raman S/N, blue-sensitive detector)
Wavelength Accuracy±0.2 nm (@1200 g/mm)
Excitation Range200–600 nm (standard)
Emission Range200–1000 nm (standard)
Detector OptionsR1527P (200–670 nm), R928P (200–870 nm), R2658P (200–1010 nm)
Stray Light Rejection<1×10⁻⁵
Integration Time10–200 s
Scan SpeedUp to 100 nm/s
Quantum Yield MeasurementIntegrated sphere-based absolute method (4-step protocol)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0